Adiabatic Accelerated Calorimeter
Product Description
Adiabatic Accelerated Calorimeter determines the thermal behavior of samples under adiabatic conditions by keeping the temperature of the environment and the reaction system equal, obtains the thermodynamic and kinetic data of the chemical reaction process in adiabatic state, and deduces the key indexes for evaluating the thermal safety of the chemicals or the chemical reaction such as TD24. TMRad, SADT, etc., so as to determine the safety conditions for the processing, storage and transportation of the chemicals accordingly. It is widely used in the research and development and optimization of chemical processes in the fields of fine chemicals, petrochemicals, agricultural fertilizers, polymers and plastics, energy-containing materials, etc.; the effective assessment of thermal hazards in the process of storage and transportation of chemicals; and the scientific research on the thermodynamics of chemical reactions. It is mainly used for chemical process research and development, process optimization and scale-up, chemical thermal hazard assessment, investigation and analysis of combustion and explosion accidents, and thermodynamic research in the fields of fine chemicals, pharmaceuticals, energy-containing materials, organic chemistry, polymers and plastics, and so on.
Standards
T/CIS 17007-2023
JJF 1059.1-2012
JJF 1001-2011
Product Features
1. Supports Heating - Waiting - Scanning (HWS) mode, constant - temperature mode, isochronous scanning mode, etc. 2. Equipped with professional data - analysis software, enabling automatic calculation of parameters such as exothermic onset temperature, adiabatic temperature rise, activation energy, and pre - exponential factor. 3. The software integrates the safety risk assessment methods and standards for reactions in the *Guidelines for Safety Risk Assessment of Fine Chemical Reactions* issued by the former State Administration of Work Safety, enabling one - stop assessment of the hazard level of reaction processes. 4. Key components are from well - known international brands, ensuring the long - term and stable operation of the instrument. 5. After the experiment, an inert gas can be introduced to rapidly cool down the furnace body. 6. Features an experimental status indication function, as well as overpressure and over - temperature alarm functions. 7. The furnace cover has an automatic lifting function, ensuring safety and facilitating operation. 8. With professional industrial design, it is simple and elegant, has a user - friendly human - machine interaction, and is easy to learn, understand, and operate. 9. The data - analysis software incorporates the differential conversion - rate thermodynamics calculation method, which has significant advantages in the calculation of the thermal decomposition kinetics of mixed materials and the prediction of thermal hazards.
Technical parameters
|
Operating Environment |
(5~40)℃, <85%RH |
|
Temperature Control Range |
Room temperature~500℃ |
|
Temperature Detection Threshold |
(0.005~0.02)℃/min |
|
Temperature Tracking Rate |
(0.005~40)℃/min |
|
Temperature Display Resolution |
0.001℃ |
|
Pressure Range |
Maximum withstand pressure 20MPa |
|
Pressure Resolution |
1kPa |
|
Sample Cell Specifications |
8mL |
|
Sample Cell Material |
Stainless steel, titanium, Hastelloy (optional) |
|
Phi Value |
≤1.35 |
|
Interfaces |
USB or RJ45 |
|
Power Supply |
AC220V/50Hz |
|
Power |
≤3000W |
|
Dimensions |
620mm*470mm *670mm |
|
Weight |
Approx. 78kg |
在线联系供应商
Other supplier products
| Syringe slide performance test device | Introduction: 5.7-inch (120 x 90) single color LCD touch screen, Chinese menu display. The nominal capacity of the syringe is selected by the ke... | |
| Abrasive Wear Test Apparatus | Standard ASTM G65 - 04 GB/T 3960-1983 Main Purposes The wet - type rubber wheel abrasive wear testing machine is primarily employed to assess t... | |
| Shoelace wear tester丨Shoelace wear test mechine | Main uses: Shoelace wear tester is mainly used to evaluate the durability and wear resistance of shoelaces. In the test, the LACES are usually fix... | |
| Temperature Oxygen Index Apparatus, ISO4589-3, Nes 715 | Introduction: Temperature Oxygen IndexApparatus belongstoantiflamingtest equipment for measuring the combustion performance of the vertical bars o... | |
| Adhesive Force Evaluation Device | The adhesion tester is a device specifically used to detect the strength of the adhesion of materials. The following is a detailed description of i... |
Same products
| Plastic Smoke Density Tester F313 | 卖方: Standard International Group (HK) Limited | The F313 Plastic Smoke Density Tester is a precision instrument designed to measure the specific ... | |
| Xenon Test Chamber | 卖方: Standard International Group (HK) Limited | Features and Benefits 1.The use of xenon arc lamp as a light source, can simulate the full sunli... | |
| Single Cable Vertical Flame Tester | 卖方: 上海千实精密仪器 | Introduction Single Cable Vertical Flame Tester is used for the vertical flame propagation of a ... | |
| Safety Helmet Flammability Tester | 卖方: 上海千实精密仪器 | Product Introduction: Safety hat flame retardant performance tester for safety hat flame retarda... | |
| Furniture flammability tester | 卖方: 上海千实精密仪器 | Product details Furniture flammability tester is mainly used to test the combustion performance ... |