Mask Breathing Resistance Testing Apparatus
Mask & Respirator Breathing Resistance Tester
Respirator Breathing Resistance Tester is used to measure the respiratory resistance and expiratory resistance of respirators and masks under the specified conditions.The flow rate for inhale resistance test is 30L/min and 95L/min.
The flow rate for exhale resistance test is 160L/min. And the flow rate for the flow impact test is 300L/min.Applicable to the national labor protection supplies inspection agency, mask manufacturers related inspection and inspection of ordinary masks, dust masks, medical masks, anti-fog mask products.
Standards
EN149-2009 section 7.15. 8.3.4.
EN 13274-3.
GB 19083.
GB 2626.
NIOSH 42 CFR Part 84.
JIS/T 8151
Maintenance
1. Do not carry it by the bottom of the control box during transportation to avoid being crushed.
2. Please wipe the electroplated part with oil to prevent rust and keep bright.
3. After the test, please wipe the machine clean, and regularly oil the active fulcrum to increase its service life and sensitivity. (The lubricating oil can be mixed with butter and a little engine oil)
4. Please wipe the panel (control box or display) with a dry cloth to prevent it from getting wet, so as not to damage the IC electronic parts.
5. Please place all fixtures and joint accessories properly, and wipe off the anti-rust oil to prevent rust.
Features
1. Touch screen control, English menu, man-machine dialogue mode, easy operation.
2. Built-in thermal printer, it is convenient to quickly print test results on site.
3. Two modes of breath detection and inhalation detection can be set.
4. The automatic switching device of the respirator pipeline solves the problem that the tester pulls out the
pipe and accidentally connects the pipeline when testing.
5. 3D printed standard head mold, which simulates the actual inhalation and exhalation of the human body,
improving the accuracy of the data.
Specification
1. The instrument consists of an air source that can adjust the flow rate, a human head mold specified in the standard, two intubation systems for inhalation and exhalation, and a respiratory resistance measurement system.
2. The flow sensor has high sensitivity and has a very small starting flow.
3. The flow sensor chip uses a thermal mass flow meter, which does not require temperature and pressure compensation, ensuring high-precision measurement of the sensor. The range of the flow meter is 0 L / min - 100L / min.
4. Multiple sensors are integrated on a single flow sensor chip, which greatly improves the range ratio of the sensor.
5. The zero point stability of the flow sensor is high, with full range and high stability, high accuracy over the full range, excellent repeatability, low power consumption, low pressure loss and fast response speed.
6. The data logger uses a graphic dot matrix LCD with a resolution of 128 * 64 and a full Chinese / English interface, which is easy to operate.
7. the data logger has 4M memory for measurement value recording.
8. The micromanometer sensor uses a two-wire system, with high accuracy and good stability; it is safe and reliable to use an explosion-proof design.
9. The range and zero point of the micromanometer sensor are continuously adjustable, the damping is adjustable, there is no mechanical moving part, and the maintenance workload is small. The micro-pressure measurement range is -1000Pa to 1000Pa, and the accuracy is 1Pa.
10. The whole instrument adopts special gas path conversion elements, which ensures the convenient and fast conversion of the two-pipe system of exhalation and inhalation.
11.The suction volume of the suction pump is not less than 40L / min - 100L / min
12. Ventilation volume is constant at 85 L / min
13. Power supply: AC220V, 50Hz
在线联系供应商
Other supplier products
| Rubber non-rotor vulcanization Tester | Product Introduction: Non-rotor vulcanizer is a rubber processing industry control rubber material quality, rapid inspection and rubber basic rese... | |
| Carpet tuft length measuring instrument | Standard BS 4223:1989 (British Standard): Specifies methods for determining the pile length of cut-pile carpets, ensuring consistency in quality... | |
| 3 Metre Cube Smoke Density Tester | None halogen cables and materials are required to measure smoke density; the main principles of the smoke density is measured in a particular space... | |
| Random Tumble Pilling Tester | G227T Random Tumble Pilling Tester-Two-box and four-box can be configured. It is mainly used in evaluating the pilling performance of textiles. The... | |
| Safety Helmets Wearing Stability Tester | Standard GB 811-2022: Safety Helmets – General Technical Requirements GB 24429-2009: Sports Helmets – Requirements and Test Methods ... |
Same products
| FH-77富氢测试笔 | 卖方: 科立龙电子股份有限公司 | 产品说明: 用于测量氢气水(富氢水)和氢气水发生器的溶解氢含量。 特征: 1、电极更换方便 智能、携带方便、操作方便、实用; 产品广泛应用于食品、环卫、地质勘探、冶金、地表水、 ... | |
| Xenon Arc Weather Ometer | 卖方: Standard Group (Hong Kong) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | 卖方: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | 卖方: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... | |
| Plastic Smoke Density Tester F313 | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ... |