.

HIV

The human immunodeficiency virus, also known as HIV, is a retrovirus that causes human cellular immune system defects.

The virus attacks and gradually destroys the human immune system, leading to pathogenic bacteria and rare tumors, with fast infection and a high fatality rate.

SEKBIOprovides anti hiv antibodyproducts: Mouse anti -HIV p24 mAb, Humanized HIV p24 antibody, HIV-1 ag1 recombinant protein, HIV-1 ag2 recombinant protein, HIV-2 gp36 recombinant protein, HIV-1 gp41 recombinant antigen, HIV-1 gp41 (group O) recombinant antigen.

The performance of our HIV markers

Performance Evaluation

Clinical Performance

The specimen correlation study was performed on 1717 specimens. 555 positive specimens and 1162 negative specimens were confirmed by EIA. Specimens were rated either positive or negative at 15 minutes and 20 minutes. The results are shown in Table 1.

Table 1: Specimen Correlation Studies

EIA

HIV 1/2

Test Device

+

-

+

554

4

-

0

1159

Positive agreement with EIA: 554/(554+0) > 99.9%

Negative agreement with EIA: 1159/(1159+4) = 99.6%

Total agreement with EIA: (554+1159)/ = 99.8%

Interfering Substances

Analytes were spiked into negative plasma and serum pools (ELISA confirmed) and low positive plasma and serum specimens (ELISA confirmed) at the concentrations listed. The specimens were tested in triplicate with 3 lots of test devices. Visual interpretations were made at 15 and 20 minutes after specimen application. The results are presented in Table 2 below.

Conclusion: No substances showed any interference with the test. There were no differences observed between the results at 15 minutes and the results at 20 minutes.

Cross-Reactivity

HCG pregnancy, HCV+,Syphilis, HbsAg+, Heterophilic, HAMA+ andRF factor+specimens specimens were confirmed by ELISA test and clinical diagnostic result and tested with theHIV 1/2 Rapid Test Device (Whole Blood/Serum/Plasma). Visual interpretations were made at 15 and 20 minutes after specimen application. The results are presented in Table 3below.

Conclusion: There was no cross-reaction withhCG pregnancy, HCV+,Syphilis, HBsAg+, Heterophilic, HAMA+ andRF factor+specimens at 20minutes.

A total of 10 sets of BBI positive control sera were tested on the chemiluminescent immunoassay platform. The evaluation was conducted by comparing with the Abbott I2000 reagents. Out of the 60 serum samples tested using the BBI positive control sera, SEKBIOassay detected 30 out of 60 samples, while the Abbott I2000 reagents detected 31 out of 60 samples. The positive agreement rate was 96.8%, the negative agreement rate was 100.0%, and the overall agreement rate was 98.3%.

HIV Antibody

HIV antibodies are effective against HIV.

The body's response to HIV is to produce antibodies to fight the virus. All people with HIV have antibodies in their bodies, but in most cases, antibodies cannot neutralize or kill different strains of the virus. Only a few broad-spectrum neutralizing antibodies can pass through the protective layer around HIV to kill the virus. HIV has a sugar-coated shell that blocks antibodies.

Broadly neutralizing antibodies offer the hope of regaining immunity in those who lack specific immune functions, and they can penetrate the sugar coat and potentially kill HIV efficiently in a shorter period.

HIV Antibody Test

HIV antibody test: The detection of HIV antibodies in the blood is the most commonly used laboratory method to detect HIV infection. Generally, it goes through two steps: first, a preliminary screening test is performed, and if it is positive, a confirmation test is performed, and a confirmation test is performed. Only positive can be diagnosed as HIV infection.

Commonly used methods are:

1 Pathogen detection

Pathogen detection mainly refers to the direct detection of viruses or virus genes from host specimens by virus isolation and culture, electron microscope morphological observation, virus antigen detection, and gene determination. Because the first two methods are complex and require special equipment and professional technicians, only antigen detection and RT-PCR (reverse transcription-PCR) can be used for clinical diagnosis.

2 Antibody detection

HIV antibody in serum is an indirect indicator to judge HIV infection. According to their primary scope of application, existing HIV antibody detection methods can be divided into screening tests and confirmatory tests.

3 Confirmation reagents

Western blot (WB) is the most commonly used method for confirming positive serum in screening experiments. Since this method has a relatively long window period, slightly poor sensitivity, and high cost, it is only suitable for confirmatory experiments. With the improvement of the sensitivity of the third and fourth-generation HIV diagnostic reagents, WB has become more and more unable to meet the requirements of confirmatory experiments.

Another FDA-approved screening confirmatory reagent type is an immunofluorescence assay (IFA). The cost of IFA is lower than that of WB, the operation is relatively simple, and the whole process can complete within 1-1.5 hours. The main disadvantage of this method is that it requires expensive fluorescence detectors and experienced professionals to observe the evaluation results, and the experimental results cannot store for a long time. The FDA now recommends that a negative or positive IFA prevail when issuing final results to blood donors who WB cannot determine, but not as a blood qualification standard.

4 Screening tests

The screening test is mainly used to screen blood donors, so it requires a simple operation, low cost, and sensitivity and specificity. At present, the primary screening method in the world is still ELISA, and there are a few particle agglutination reagents and rapid ELISA reagents.

ELISA has high sensitivity and specificity and is easy to operate. It is especially suitable for large-scale screening in the laboratory. It only needs a microplate reader and a plate washer to be applied in the laboratory.

Particle agglutination test is another simple, convenient, and low-cost detection method. The results of this method can be judged by the naked eye and have high sensitivity. It is especially suitable for developing countries or when screening many blood donors. The disadvantage is that it must use fresh samples, poor specificity.

The dot-blot assay developed in the late 1980s is a rapid ELISA (Rapid ELISA) method. This method is straightforward to operate, and the process is short. Most of the whole process is completed within 5-10 minutes or even 3 minutes. But this method is much more expensive than ELISA and particle agglutination reagents.

Gold immunoassay is a solid-phase immunoassay using colloidal gold as a marker and a nitrocellulose membrane as a carrier. It is divided into two forms: diafiltration and chromatography. Gold test strips used for HIV antibody samples belong to gold immunochromatography, and most of them are indirect methods and double antigen sandwich methods. Both approaches have advantages and disadvantages, but they are fast and straightforward, and conclusions can draw in a few minutes. No equipment is required, no special training is needed for operators, and the reagents are stable, suitable for single determination, etc.



在线联系供应商

至: Shenzhen SEKBIO Co., Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Thyroid Function
Thyroid Function Thyroid Function The thyroid gland is a 2-inches long, butterfly-shaped endocrine gland generally located in the lower front of the neck. The thyr...
HE4 Tumor Marker
HE4 Tumor Marker Human Epididymis Protein 4 (HE4 tumor marker) Is a Secreted Glycoprotein that Serous and Endometrioid Ovarian Carcinomas overexpress. CA 125 is th...
25-OH Vitamin D
25-OH Vitamin D 25OH Vitamin D Vitamin D is converted to 25-hydroxyvitamin D (25OHD) by hydroxylation in the liver and the active 1, 25-dihydroxy vitamin D in the...
Thyroid Function
Thyroid Function Thyroid Function The thyroid gland is a 2-inches long, butterfly-shaped endocrine gland generally located in the lower front of the neck. The ...
Recombinant Human Neuron-specific Enolase (Prokaryotic NSE  Protein Full Length)
Recombinant Human Neuron-specific Enolase (Prokaryotic NSE  Protein Full Length) Name: Recombinant human neuron-specific enolase (Prokaryotic NSE protein full length) Catalog No.: ZLP113-1 Description: Recombinant protein Epi...
供应产品

Same products

医药包装材料用0.2-0.6mm透明PVC硬片
医药包装材料用0.2-0.6mm透明PVC硬片 卖方: Henan Hongchang Aluminum Co., Ltd. PVC固体药用硬片主要原材料为聚氯乙烯树脂,该包装材料表面光洁、透明、厚薄均匀。具有易成型,易与PTP铝箔封合,有良好的氧气阻隔性及水蒸气阻隔性能,成型后泡罩坚挺,可对内容物有较好的支撑保护作用...
 PMMA scrap for sale, Acrylic scrap supplier, PMMA Acrylic scrap for sale, pmma acrylic scrap supplier
PMMA scrap for sale, Acrylic scrap supplier, PMMA Acrylic scrap for sale, pmma acrylic scrap supplier 卖方: Ivory Hong Recycling 在 IvoryPhar Inc,我们致力于促进当今行业的可持续性和负责任的材料管理。我们很高兴提供持续供应的 PMMA(聚甲基丙烯酸甲酯)废料供出售。这种高品质材料为希望将再生塑料整合到制造流程...
 HDPE Regrinds from Drums Blue, HMW HDPE Drum Regrind, HDPE scrap suppliers
HDPE Regrinds from Drums Blue, HMW HDPE Drum Regrind, HDPE scrap suppliers 卖方: Ivory Hong Recycling 在 IvoryPhar Inc,我们致力于推进可持续发展并推广负责任的回收实践。我们很高兴能够持续供应来自蓝色桶的 HDPE(高密度聚乙烯)再生料。这种材料为希望将回收材料整合到制造流程中同时为...
 Baled HDPE Milk, HDPE bottle scrap supplier, HDPE milk bottle scrap supplier
Baled HDPE Milk, HDPE bottle scrap supplier, HDPE milk bottle scrap supplier 卖方: Ivory Hong Recycling 在 IvoryPhar Inc,我们致力于推进可持续发展和负责任的资源管理。我们很高兴能够持续供应 HDPE(高密度聚乙烯)废瓶,为希望将回收材料纳入生产流程同时为环境保护做出贡献的企业提供宝贵...
  pu foam scrap for sale, scrap foam supplier, polyurethane foam scrap, PU foam scrap supplier
pu foam scrap for sale, scrap foam supplier, polyurethane foam scrap, PU foam scrap supplier 卖方: Ivory Hong Recycling 在 IvoryPhar Inc,我们致力于可持续发展和负责任的资源管理。我们很高兴提供持续供应的聚氨酯泡沫废料,非常适合寻求将再生材料融入其产品的企业。我们的废料广泛应用于家具制造、汽车和绝缘等...