LBS 24KV 630a SF6 Gas Load Break Switch
LBS 24KV 630a SF6 Gas Load Break Switch
24kV SF6 load break switchis a sf6 load break switch for medium voltage switchgear, using SF6 gas as arc extinguishing and insulating medium. Rate voltage was 24kV, rate current was630A
LBS 24KV 630aSF6 Gas Load Break Switch Application
The SF6 LBS 24kv 630A gas-insulated switch is a three-phase interoperable switching device designed for use in electrical distribution cabinet cabling and overhead power line segment applications.
The 24KV pole mounted disconnect switch can be operated manually in the field or remotely from the control center.
LBS 24KV 630a SF6 Gas Load Break Switch Technical Parameters
|
Products Type |
FWX-24 |
|
Basic Ratings |
|
|
Maximum System Voltage |
24kV |
|
Rated Continuous Current |
630A |
|
Rated Frequency |
50/60Hz |
|
Short Time Withstand Current |
16kA/1sec |
|
Making and Breaking Capacity |
|
|
Mainly Active Load Current |
630A |
|
Number of Load-break Operations |
400times |
|
Short-circuit Making Current (peak) |
40kA |
|
Number of Making Operations |
5 times |
|
Cable Charging Current |
25A |
|
Line Charging Current |
|
|
Closed Loop Circuit Current |
630A |
|
Transformer Magnetizing Current |
22A |
|
Power Frequency Withstand Current Test |
|
|
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
50kV |
|
DryCondition-1min,Ph- Ph, Phase to Earth |
64kV |
|
Dry Condition - 1 min Across Interrupter |
79kV |
|
Impulse Withstand Current Test( 1.2 x 50 µs ) |
|
|
Phase to Phase, Phase to Earth |
125kV |
|
Across Interrupter |
145kV |
|
Other Ratings & Specifications |
|
|
Internal Arc Test |
20kA /0.1 sec |
|
Arc Extinction Medium |
SF6 Gas |
|
Insulation Medium |
SF6 Gas |
|
Creepage Distance (Porcelain) |
700mm |
|
Creepage Distance (Silicon) |
1200mm |
|
Dry arcing distance |
≥ |
|
IP Level |
65 |
|
Operation Performance |
|
|
Closing/Opening Time |
<1sec |
|
Mechanical Operations (Guaranteed) |
10000times |
|
Operating Temperature (*Manual Type) |
-25~+70℃ |
|
Gas Pressure |
|
|
Nominal Pressure (MPa, at 20°C) |
|
|
Bursting Pressure (MPa) |
|
|
Minimum Gas Pressure (MPa) |
|
|
Leakage Rate (cc/ sec) |
≤0.5% |
|
Voltage sensors |
|
|
CT ABC 10P10 5VA |
400:05:00 |
|
Incoming side and outgoing side of the voltage sensor |
6 Voltage sensor(built-in) |
|
Phase voltage:(24(36)kV/√3)/(3.25V/√3) |
|
|
Special attention should be paid to the voltage sensor, which must be directly fed by the LBS load break switch. |
|
|
No additional adjustment circuit can be added to the controller. The voltage signal of the switch into the test line needs to be tested separately. |
|
If you are looking for a reliable electric power equipment company, please choose us, and we will be your best partner.
Send product request
Other supplier products
| 11KV Auto Recloser Vacuum Circuit Breaker | ZW32 series 11 kv outdoor vacuum circuit breakers are used in distribution systems and pole mounted recloser. 11kv outdoor circuit breakers are use... | |
| Recloser Control Box-Feeder Terminal Unit | Recloser Control Box-Feeder Terminal Unit The feeder terminalunit(FTU) is a new HV switch control device of control cabinet enclosures equipped wi... | |
| 11KV Vacuum Circuit Breaker | ZW32 series 11kv vacuum circuit breaker are used in distribution systems. 11kv auto reclosersare used to make and break normal and fault currents. ... | |
| Power Distribution Equipment | The intelligent AC/DC power distribution box is a distribution automation measurement and control terminal applied to line distribution transformer... | |
| 33KV SF6 Gas Load Break Switch | These load break switch 33kvare intended for outdoor applications. They can be mounted either horizontally or vertically, and are suitable for elec... |