LBS 24KV 630a SF6 Gas Load Break Switch
LBS 24KV 630a SF6 Gas Load Break Switch
24kV SF6 load break switchis a sf6 load break switch for medium voltage switchgear, using SF6 gas as arc extinguishing and insulating medium. Rate voltage was 24kV, rate current was630A
LBS 24KV 630aSF6 Gas Load Break Switch Application
The SF6 LBS 24kv 630A gas-insulated switch is a three-phase interoperable switching device designed for use in electrical distribution cabinet cabling and overhead power line segment applications.
The 24KV pole mounted disconnect switch can be operated manually in the field or remotely from the control center.
LBS 24KV 630a SF6 Gas Load Break Switch Technical Parameters
|
Products Type |
FWX-24 |
|
Basic Ratings |
|
|
Maximum System Voltage |
24kV |
|
Rated Continuous Current |
630A |
|
Rated Frequency |
50/60Hz |
|
Short Time Withstand Current |
16kA/1sec |
|
Making and Breaking Capacity |
|
|
Mainly Active Load Current |
630A |
|
Number of Load-break Operations |
400times |
|
Short-circuit Making Current (peak) |
40kA |
|
Number of Making Operations |
5 times |
|
Cable Charging Current |
25A |
|
Line Charging Current |
|
|
Closed Loop Circuit Current |
630A |
|
Transformer Magnetizing Current |
22A |
|
Power Frequency Withstand Current Test |
|
|
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
50kV |
|
DryCondition-1min,Ph- Ph, Phase to Earth |
64kV |
|
Dry Condition - 1 min Across Interrupter |
79kV |
|
Impulse Withstand Current Test( 1.2 x 50 µs ) |
|
|
Phase to Phase, Phase to Earth |
125kV |
|
Across Interrupter |
145kV |
|
Other Ratings & Specifications |
|
|
Internal Arc Test |
20kA /0.1 sec |
|
Arc Extinction Medium |
SF6 Gas |
|
Insulation Medium |
SF6 Gas |
|
Creepage Distance (Porcelain) |
700mm |
|
Creepage Distance (Silicon) |
1200mm |
|
Dry arcing distance |
≥ |
|
IP Level |
65 |
|
Operation Performance |
|
|
Closing/Opening Time |
<1sec |
|
Mechanical Operations (Guaranteed) |
10000times |
|
Operating Temperature (*Manual Type) |
-25~+70℃ |
|
Gas Pressure |
|
|
Nominal Pressure (MPa, at 20°C) |
|
|
Bursting Pressure (MPa) |
|
|
Minimum Gas Pressure (MPa) |
|
|
Leakage Rate (cc/ sec) |
≤0.5% |
|
Voltage sensors |
|
|
CT ABC 10P10 5VA |
400:05:00 |
|
Incoming side and outgoing side of the voltage sensor |
6 Voltage sensor(built-in) |
|
Phase voltage:(24(36)kV/√3)/(3.25V/√3) |
|
|
Special attention should be paid to the voltage sensor, which must be directly fed by the LBS load break switch. |
|
|
No additional adjustment circuit can be added to the controller. The voltage signal of the switch into the test line needs to be tested separately. |
|
If you are looking for a reliable electric power equipment company, please choose us, and we will be your best partner.
在线联系供应商
Other supplier products
| SF6 Gas 11 KV Load Break Switch | The 11 kv load break switchis suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency ... | |
| Recloser Control Box-Feeder Terminal Unit | The feeder terminal unit(FTU) is a new HV switch control device of control cabinet enclosures equipped with both the imported DSP high-speed sampli... | |
| 11KV SF6 Gas Load Break Switch | The FWX1-12/630 outdoor SF6 load break switch is suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and t... | |
| Distributed Type DTU | The distributed DTU power distribution terminal is suitable for the protection, measurement and control, and communication of the interval unit of ... | |
| 11KV Vacuum Circuit Breaker | ZW32 series Breakers are used in distribution systems. Circuit breakers are used to make and break normal and fault currents. Breakers are fully eq... |