40KA AC Power SPD
40KA AC Power SPD
SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication
Features & Advantages of 40KA SPD
Status indication:
Green: OK
Red: Failed
Lightning surge protection device modules can be replaced online.
Remote alarm output is optional, named with "F".
It is normally installed at the boundary of LPZ1 and LPZ2 or subsequent LPZs.
Parameter of 40KA AC Power SPD
Recommended backup fuse |
80A gG |
80A gG |
80A gG |
80A gG |
80A gG |
80A gG |
80A gG |
Recommended grounding cable |
6~35mm2 |
6~35mm2 |
6~35mm2 |
6~35mm2 |
6~35mm2 |
6~35mm2 |
6~35mm2 |
Response time |
25ns |
25ns |
25ns |
25ns |
25ns |
25ns |
25ns |
Residual current IPE |
<10µA |
<10µA |
<10µA |
<10µA |
<10µA |
<20µA |
<20µA |
Remote alarm output |
250VAC/0.5A;24VDC/0.5A |
250VAC/0.5A;24VDC/0.5A |
250VAC/0.5A;24VDC/0.5A |
250VAC/0.5A;24VDC/0.5A |
250VAC/0.5A;24VDC/0.5A |
250VAC/0.5A;24VDC/0.5A |
250VAC/0.5A;24VDC/0.5A |
Housing protection grade(IEC60529) |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
Housing material/inflammability rating(UL94) |
PA66/V0 |
PA66/V0 |
PA66/V0 |
PA66/V0 |
PA66/V0 |
PA66/V0 |
PA66/V0 |
Testing standard |
IEC 61643-11 |
IEC 61643-11 |
IEC 61643-11 |
IEC 61643-11 |
IEC 61643-11 |
IEC 61643-11 |
IEC 61643-11 |
Suitable for power supply system |
TN system(single phase) |
IT,TN-C system(three phase) |
TN-S system(three phase) |
IT,TN-C system(three phase) |
TN-S system(three phase) |
If you want to know more about safety and automation system, please contact us.
CHENZHUhas got intergraded management service Certificates, like ISO9001, ISO14001 and OHSAS45001, more than 110 patents related core tech was obtained, reference OEM and ODM customers from German, Japan and direct shipments to any global destinations.
Send product request
Other supplier products
The Principle and Classification of Safety Barriers | China safety barrier is generally used in intrinsic safety systems. Intrinsic safety refers to system explosion-proof technology, which refers to t... | |
20KA AC Power SPD | SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 10kA/phase, Imax: 20kA/phase; hot-pluggable; fault indication. Features & Adv... | |
Power Transmitter | Power transmittercan transfer complicated current like 0~1A/0~5A/0~10A into industry-standard output, adopting the true RMS detection technology. W... | |
Signal Conditioner | Universal signal conditioner is used in industrial process control systems. Isolated signal conditionerconnects industrial field instruments and co... | |
Photovoltaic 1000 DC Power SPD | SPD for DC power, SPD1000VDC; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovolta... |
Same products
4000W PURE SINE WAVE INVERTER CHARGER | Seller: Suzhou Cosuper Energy Technology Co., Ltd | The Cosuper CPT4000 watt pure sine inverter chargeris a 3-in-1 power solution system that combine... | |
C2-LFP100WS | Seller: Eco Power Group | LiFePO4 batteries with 100ah lifepoare a popular choice for energy storage due to their high ener... | |
Power fixture | Seller: Zhejiang Liangheng Electric Technology Co. , Ltd. | Power fixture | |
Lifepo4 Power Station 500W | Seller: Shenzhen Houny Battery Co., Ltd | Specification 1) Output power: The rated 500W Peak 1000W 2) Output voltage: AC100-110V/220-24... | |
40KA AC Power SPD | Seller: Shanghai Chenzhu Instrument Co., Ltd. | 40KA AC Power SPD SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 20kA/phase, Ima... |