5a current transformer split core
DPSeriesretro-fitsplit-corecurrenttransformerhavebeenspecificallydesignedtobeeasytoopenandyetmaintaintheaccuracyrequiredforintelligentmeters,quicktofitaroundcables.AninternalprecisionresistoracrossthesecondarywindingoftheCTprovidesalowsafevoltageoutput.Itcanbeplacedintopositioneasilyandwithoutdisturbingordisconnectingthemaincablesititmonitoring.
Feature:1)Double-screwfastening,safe,easytoinstall,portable.2)Wideinnerwindow,allowingclampingofbigcablesorbus-bars.3)Widerangeofsizestoaccommodatealltheexistinginstallations.4)Primarycurrentfrom5Ato5000A.
Advantage:1.AllthecasesaremadeofimportUSAdupontPAmaterials,nottheABSmaterialcase,
Sothetemperatureendurenceismuchhigher;2.Allthecoresaremadeofimportedhighestqualitysiliconironsheet,Sothecore'smagnetic
performanceismuchhigher;3.Alltheparametersaredoublecross-checked,sothetestingresultsismuchensured!
Smallsizeandeasymounting4.Wideinnerwindow,allowingclampingofbigcablesorbusbars5.Widerangeofsize
Applications:
1)Currentmeasurement,monitoringandprotectionforelectricalwiringandequipment.
2)Currentandpowermeasurementforelectricmotors,lighting,aircompressor,heating
andventilationsystem,air-conditionequipmentandautomation-controlsystem.
3)Current,powerandenergymonitoringdevice.
4)Relayprotectiondevice.
STANDARD:IEC6044-1,EN60044-1,VDE0414-44-1,GB1208-2006
Primarycurrent: |
5A-5000A |
Secondarycurrent: |
0-5A |
Standardapproval: |
IEC44-1,BS7626 |
Maximumvoltage: |
|
Frequency: |
50/60Hz |
Ratedload: |
1VA-30VA |
Class: |
|
Short-timethermalcurrent: |
Ith=100xIn |
Ratedsecuritycoefficient: |
FS<5 |
Send product request
Other supplier products
low voltage current transformer 5a | TheMESseriesofcurrenttransformerareconvenientformountinginmanyways.ThemostcurrenttransformerneedthespecialmountingandtheMESseriesusedthemountingofD... | |
busbar current transformer 5a | MSQseriesofcurrenttransformercanbeappliedtotest,control,displayandrecordtherunningoftheelectricalequipment,andtoprotecttheequipmentagainstthedamage... | |
split core current transforner | MODEL KCT-6 CurrentRatio 5A/2.5mA 10A/5mA 20A/10mA PrimaryCurrent(A) 5A 10A 20A 30 30 30 Output 5mA 5mA... | |
split core current transforner | MODEL KCT-6 CurrentRatio 5A/2.5mA 10A/5mA 20A/10mA PrimaryCurrent(A) 5A 10A 20A 30 30 30 Output 5mA 5mA... | |
toroidal current transformer | RCTSeriesCurrentTransformerisforindoorandsuitableforusinginthecircuitthatratedvoltageupto0.5kv,frequency50Hztodothecurrent,powermeasuringorrelaypro... |
Same products
ACREL AID150 ALARM AND DISPLAY DEVICE | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |