oil-immersed power transformers

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.



Send product request

To: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Dry type Power Transformers
Dry type Power Transformers Product Description SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) d...
How to calculate the calorific value of transformer
How to calculate the calorific value of transformer How to calculate the calorific value of transformer The calorific base of transformer = no load loss + load loss. No-load loss: when the transforme...
Do You Know What Is The Short Circuit Impedance of The Transformer?
Do You Know What Is The Short Circuit Impedance of The Transformer? process of using, it is necessary to enhance the continuous improvement of the use and efficiency of the transformer such asDry Type Transformer....
How to calculate the calorific value of transformer?
How to calculate the calorific value of transformer? How to calculate the calorific value of transformer? The calorific base of transformer = no load loss + load loss. No-load loss: when the transfo...
How to Dry the Transformer?
How to Dry the Transformer? Transformers such asOil Immersed Transformerare sometimes wet, especially in the summer when the transformer is relatively powerful, and the power...
All supplier products

Same products

S11-M Power Transformer
S11-M Power Transformer Seller: Bokong Electric Co., Ltd S11-M Product Description S11-M a new generation of low noise and low loss transformer devel...
Compact Transformer
Compact Transformer Seller: Shaanxi Hanzhong Transformer Co., ltd As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com...
Combined Pad Mounted Substation
Combined Pad Mounted Substation Seller: Shaanxi Hanzhong Transformer Co., ltd Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a...
Amorphous Alloy Dry Type Transformer
Amorphous Alloy Dry Type Transformer Seller: Shaanxi Hanzhong Transformer Co., ltd SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie...
35KV Power Transformer
35KV Power Transformer Seller: Shaanxi Hanzhong Transformer Co., ltd This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ...