.

oil-immersed power transformers

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.


Send product request

To: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

non-encapsulated H-class dry-type power transformers
non-encapsulated H-class dry-type power transformers SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers...
Fixed mounted Switchgear
Fixed mounted Switchgear Low Voltage Switchgear High and Low Voltage Switchgears GGD series low voltage switchgearis used for power lighting Product Description GGD series ...
oil immersed power transformer
oil immersed power transformer Oil Immersed Transformer The transformer is completely hermetical oil-immersed type. The principle is the same as the hermetical power transformer....
Distinguish Between Dry Type Transformer and Oil Immersed Transformer from The Outside
Distinguish Between Dry Type Transformer and Oil Immersed Transformer from The Outside The biggest difference between anOil Immersed Transformerand aDry Type Transformeris that there is no "oil". Since the oil is liquid and has fluid...
step up dry transformer
step up dry transformer step up dry transformer Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, eas...
All supplier products

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER Seller: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...