oil-immersed power transformers

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.



在线联系供应商

至: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

oil-immersed power transformers
oil-immersed power transformers The calorific base of transformer = no load loss + load loss. No-load loss: when the transformer secondary winding is open and the primary winding ...
Transformer Fault Reasons And Preventive Measures
Transformer Fault Reasons And Preventive Measures Oill Transformer Manufacturertells us that operators should be familiar with the causes of transformer faults so that they can take timely treatm...
oil immersed power transformer
oil immersed power transformer Oil Immersed Transformer The transformer is completely hermetical oil-immersed type. The principle is the same as the hermetical power transformer....
oil-immersed power transformers
oil-immersed power transformers The calorific base of transformer = no load loss + load loss. No-load loss: when the transformer secondary winding is open and the primary winding...
three phase variable transformer
three phase variable transformer 3 phase step down transformer Oil Immersed Transformer Model and Meaning Model No. Rated CapacityKVA Rated Voltage KV Connection Group Sy...
供应产品

Same products

ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane...
ACREL DTSD1352-C SOLAR INVERTER SMART METER
ACREL DTSD1352-C SOLAR INVERTER SMART METER 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins...