6pins Digital Passive Infrared Sensor BS612

Senba Sensing Technology Co.,Ltd. is a professional china sensor manufacturer. We provide Infrared Thermopile Sensor, Digital PIR Sensor, passive ir motion sensorand so on. Want to know about china infrared sensorand lcr 0202 datasheet? Please contact us.

Overview

Senba Pyroelectric Infrared Sensors with high sensitivity, low noise and reliable performance. We have our own research and development department, with international technology and Hybrid IC technique expertise developed more than 15 years. The goods come standard with enhanced immunity to RFI (Radio Frequency Interference) bs612and 2.4G high frequency interference. Senba PIR bs612sensor suppport delay time, sensitivity adjustable, lighting adjustable.

Features

Schmidt REL output

Low voltage, low power consumption, instantaneous settling after power up

Technical Data

  1. Maximum Ratings

Characteristics

Symbol

Unit

Remarks

Supply Voltage

VDD

-0.3

V

Working Temperature

TST

-20

85

Into

-100

100

mA

Storage Temperature

TST

-40

125

Characteristics

Symbol

Type

Unit

Remarks

Supply Voltage

VDD

3

V

IR=0.5mA

Working Current

IDD

9

11

μA

Sensitivity

VSENS

90

2000

μV

Output REL

Output Low Current

IOL

10

mA

VOL<1V

Output High Current

IOH

-10

mA

VOL>(VDD-1V)

Lock time

TOL

2

s

On-time

TOH

2

4793

s

SENS/ONTIME

Input voltage

0

VDD

V

0VtoVDD/2

Input Bias Current

-1

1

μA

OEN

Input Low Voltage

VIL

Vdd

Input High Voltage

VIH

Vdd

Input Current

II

-1

1

μA

VSS<VIN<VDD

Oscillator & Filter

Low pass filter cut-off frequency

7

Hz

High pass filter cut-off frequency

Hz

Oscillator frequency on Chip

FCLK

64

kHz

Interior Block Diagram

Applications

start air conditioning or turn on the lights.

Toys

Digital photo frame

TV, Refrigerator, Air-conditioner

FAQ

Five Causes of PIR False Alarms. The first cause of PIR false alarms is low or unstable voltage at the detector. Test to make sure the voltage at each PIR is above 13VDC and stable. The second cause of false alarms is sudden infrared movement / heat changes in view of the detector.

When the sensor is idle, both slots detect the same amount of IR, the ambient amount radiated from the room or walls or outdoors. When a warm body like a human or animal passes by, it first intercepts one half of the PIR sensor, which causes a positive differential change between the two halves.


Send product request

To: Senba Sensing Technology Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

3Pins Electronic Components PIR BL312 From Senba Factory
3Pins Electronic Components PIR BL312 From Senba Factory Overview Senbais the specialist PIR manufacturer for more than 15 years. We are the most advanced factory with complete categories. With strong R&...
6pins Digital Passive Infrared Sensor BS612
6pins Digital Passive Infrared Sensor BS612 Overview Senba is one of the most professionalPIR sensor manufacturersfor more than 15 years. We are the most advanced factory with complete categ...
Dual Elements Passive Infrared Sensor Used for Alarm System D203B
Dual Elements Passive Infrared Sensor Used for Alarm System D203B Overview of outdoor dual technology motion sensors D203B with big angle windows. It widely used in light sensor.Dual compensated sensing elements a...
Long Distance 12M Detector Sensor HM412 From Senba Factory
Long Distance 12M Detector Sensor HM412 From Senba Factory Overview PIR sensors allow you to sense motion, almost always used to detect whether a human has moved in or out of the sensors range. This kind of...
Fast Response Light Dependent Resistor φ10 Series for Light Switch
Fast Response Light Dependent Resistor φ10 Series for Light Switch Featureof light sensitive resistor Coated with epoxy Good reliability Small volume Good spectrum characteristic Standard Type and Specifications ...
All supplier products

Same products

China factory Signal control board DK-MCJ3004 for power station
China factory Signal control board DK-MCJ3004 for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Signal control board DK-MCJ3004 for power station Sold by YOYIK. Deyang YOYIK is a...
Made in China Signal board 6ES7288-5CM01-0AA0 for thermal power plant
Made in China Signal board 6ES7288-5CM01-0AA0 for thermal power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "Made in China Signal board 6ES7288-5CM01-0AA0 for thermal power plant Selection of advanced tech...
China made Small machine dual LVDT sensor TDZ-1 for power plant
China made Small machine dual LVDT sensor TDZ-1 for power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China made Small machine dual LVDT sensor TDZ-1 for power plant Deyang YOYIK is a strong technic...
Linear displacement sensor 181.36.06.G02 power plant
Linear displacement sensor 181.36.06.G02 power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China supplier Linear displacement sensor 181.36.06.G02 power plant spare parts Main: hydraulic ...
China factory Limit switch DE Ll LX918-11L for power station
China factory Limit switch DE Ll LX918-11L for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD China factory Limit switch DE Ll LX918-11L for power station YOYIK is a research and development,...