6pins Digital Passive Infrared Sensor BS612

Senba Sensing Technology Co.,Ltd. is a professional china sensor manufacturer. We provide Infrared Thermopile Sensor, Digital PIR Sensor, passive ir motion sensorand so on. Want to know about china infrared sensorand lcr 0202 datasheet? Please contact us.

Overview

Senba Pyroelectric Infrared Sensors with high sensitivity, low noise and reliable performance. We have our own research and development department, with international technology and Hybrid IC technique expertise developed more than 15 years. The goods come standard with enhanced immunity to RFI (Radio Frequency Interference) bs612and 2.4G high frequency interference. Senba PIR bs612sensor suppport delay time, sensitivity adjustable, lighting adjustable.

Features

Schmidt REL output

Low voltage, low power consumption, instantaneous settling after power up

Technical Data

  1. Maximum Ratings

Characteristics

Symbol

Unit

Remarks

Supply Voltage

VDD

-0.3

V

Working Temperature

TST

-20

85

Into

-100

100

mA

Storage Temperature

TST

-40

125

Characteristics

Symbol

Type

Unit

Remarks

Supply Voltage

VDD

3

V

IR=0.5mA

Working Current

IDD

9

11

μA

Sensitivity

VSENS

90

2000

μV

Output REL

Output Low Current

IOL

10

mA

VOL<1V

Output High Current

IOH

-10

mA

VOL>(VDD-1V)

Lock time

TOL

2

s

On-time

TOH

2

4793

s

SENS/ONTIME

Input voltage

0

VDD

V

0VtoVDD/2

Input Bias Current

-1

1

μA

OEN

Input Low Voltage

VIL

Vdd

Input High Voltage

VIH

Vdd

Input Current

II

-1

1

μA

VSS<VIN<VDD

Oscillator & Filter

Low pass filter cut-off frequency

7

Hz

High pass filter cut-off frequency

Hz

Oscillator frequency on Chip

FCLK

64

kHz

Interior Block Diagram

Applications

start air conditioning or turn on the lights.

Toys

Digital photo frame

TV, Refrigerator, Air-conditioner

FAQ

Five Causes of PIR False Alarms. The first cause of PIR false alarms is low or unstable voltage at the detector. Test to make sure the voltage at each PIR is above 13VDC and stable. The second cause of false alarms is sudden infrared movement / heat changes in view of the detector.

When the sensor is idle, both slots detect the same amount of IR, the ambient amount radiated from the room or walls or outdoors. When a warm body like a human or animal passes by, it first intercepts one half of the PIR sensor, which causes a positive differential change between the two halves.


Отправить запрос, связаться с поставщиком

Кому: Senba Sensing Technology Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Dual Elements Passive Infrared Sensor Used for Alarm System D203B
Dual Elements Passive Infrared Sensor Used for Alarm System D203B Overview D203B(dualtech detector)with big angle windows. It widely used in light sensor.Dual compensated sensing elements are applied to suppress ...
Low Distortion Coupling Linear Optocoupler LCR - 0203 Series for Volume Control and Electrical Coupling
Low Distortion Coupling Linear Optocoupler LCR - 0203 Series for Volume Control and Electrical Coupling An Overview of Low Distortion Coupling Linear Optocoupler lcr 0203Series for Volume Control and Electrical Coupling Optocoupler is an electronic co...
4pins Digital Smart Pyroelectric Detector BS412
4pins Digital Smart Pyroelectric Detector BS412 Overview of pyroelectric motion sensor BS412 is a newest smart digital motion detector with a small window size. It offers a complete motion detect...
Fast Response Light Dependent Resistor φ10 Series for Light Switch
Fast Response Light Dependent Resistor φ10 Series for Light Switch With our own R&D Center, SenbaSensor can do a lot of basic research, and develop our chinese pirsensor and other products with our unique techn...
Digital Control Circuit Sensitive Element BS312
Digital Control Circuit Sensitive Element BS312 Overview PIR sensor sense the motion object, always used to detet the human. There is a detect rang for the PIR sensor. When a people move in or ou...
Все товары поставщика

Похожие товары

China factory Signal control board DK-MCJ3004 for power station
China factory Signal control board DK-MCJ3004 for power station Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Signal control board DK-MCJ3004 for power station Sold by YOYIK. Deyang YOYIK is a...
Made in China Signal board 6ES7288-5CM01-0AA0 for thermal power plant
Made in China Signal board 6ES7288-5CM01-0AA0 for thermal power plant Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "Made in China Signal board 6ES7288-5CM01-0AA0 for thermal power plant Selection of advanced tech...
China made Small machine dual LVDT sensor TDZ-1 for power plant
China made Small machine dual LVDT sensor TDZ-1 for power plant Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China made Small machine dual LVDT sensor TDZ-1 for power plant Deyang YOYIK is a strong technic...
Linear displacement sensor 181.36.06.G02 power plant
Linear displacement sensor 181.36.06.G02 power plant Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China supplier Linear displacement sensor 181.36.06.G02 power plant spare parts Main: hydraulic ...
China factory Limit switch DE Ll LX918-11L for power station
China factory Limit switch DE Ll LX918-11L for power station Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD China factory Limit switch DE Ll LX918-11L for power station YOYIK is a research and development,...