0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm2)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.00.31.110.212.12451×61.01.07.28.50.31.110.812.62751×101.01.08.19.50.31.211.913.83551×161.01.19.310.70.31.213.115.04401×251.21.211.513.20.31.315.417.76001×351.21.212.314.10.31.416.518.87201×501.41.314.115.90.31.418.220.69101×701.41.315.817.80.31.520.223.011701×951.61.418.120.20.31.622.625.615101×1201.61.520.022.40.31.724.727.718301×1501.81.622.024.60.31.826.930.121601×1852.01.724.427.00.451.930.233.927901×2402.21.827.530.30.452.033.537.335301×3002.41.930.433.60.452.136.640.54280Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.40.31.212.714.73102×2.50.81.19.811.40.31.213.615.53552×41.01.211.813.50.31.315.718.04752×61.01.212.914.60.31.417.019.35802×101.01.314.916.80.31.419.021.47502×161.01.417.119.10.31.521.424.39802×251.21.521.223.70.31.725.929.013802×351.21.623.125.70.31.828.031.217102×501.41.726.529.20.452.032.536.323702×701.41.930.333.50.452.136.540.531002×951.62.134.938.20.452.341.446.040202×1201.62.238.442.20.452.545.450.148703×1.50.81.19.611.00.31.213.315.33453×2.50.81.110.412.10.31.314.416.44053×41.01.212.614.30.31.316.518.85403×61.01.213.815.50.31.417.920.26603×101.01.315.917.80.31.520.223.09103×161.01.418.220.30.31.622.825.712003×251.21.622.925.40.31.827.830.917603×351.21.724.927.60.451.930.734.422603×501.41.828.531.30.452.034.538.428803×701.42.032.735.90.452.239.043.538003×951.62.237.541.00.452.444.348.948903×1201.62.341.345.30.452.648.553.760703×1501.82.545.849.90.452.853.358.772703×1852.02.750.955.50.453.058.864.989703×2402.22.957.562.40.453.265.872.213504×1.50.81.110.512.10.31.314.416.43954×2.50.81.111.413.10.31.315.417.64654×41.01.213.815.60.31.417.920.36404×61.01.315.317.30.31.519.622.57904×101.01.417.719.70.31.622.225.110704×161.01.520.322.80.31.725.028.114604×251.21.725.528.10.451.931.335.021404×351.21.827.730.50.452.033.737.526704×501.41.931.835.00.452.238.142.136304×701.42.136.339.70.452.443.147.747404×951.62.341.745.70.452.648.954.162904×1201.62.546.250.30.452.853.759.276705×1.50.81.111.413.10.31.315.417.64557×1.50.81.212.614.40.31.316.618.953012×1.50.81.316.818.80.31.521.224.079019×1.50.81.419.922.40.31.624.427.5108027×1.50.81.624.326.90.31.829.232.8146037×1.50.81.727.430.40.451.933.237.019905×2.50.81.212.714.40.31.316.618.95607×2.50.81.213.915.60.31.418.020.365012×2.50.81.418.720.80.31.623.226.297019×2.50.81.522.124.70.31.726.830.01360
Other supplier products
|
|
Armoured Current-Carrying Capacities (Amp) |
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (Single Core)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/AWA/PVC 600/1000V Clas... |
|
|
NYM-J / NYM-O |
German Standard Industrial Cables NYM-J / NYM-O Application and DescriptionNYM is suitable for industrial and home applications. It is designed for... |
|
|
600 1000V XLPE Insulated, PVC Sheathed, Screened Power Cables (3C+3E) |
600/1000V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (3C+3E)CU/XLPE/CUTO/PVC 600/1000V Class 2Application:The cables are designed... |
|
|
600 1000V XLPE Insulated, PVC Sheathed, Double Steel Tape Armoured Power Cables (3 Cores) |
600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (3 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application... |
|
|
Type 241 1.1 To 11KV To AS/NZS 1802 |
Type 241 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are designed for various uses,Website:, including main feeder cable for continuous mine... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |