0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm2)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.00.31.110.212.12451×61.01.07.28.50.31.110.812.62751×101.01.08.19.50.31.211.913.83551×161.01.19.310.70.31.213.115.04401×251.21.211.513.20.31.315.417.76001×351.21.212.314.10.31.416.518.87201×501.41.314.115.90.31.418.220.69101×701.41.315.817.80.31.520.223.011701×951.61.418.120.20.31.622.625.615101×1201.61.520.022.40.31.724.727.718301×1501.81.622.024.60.31.826.930.121601×1852.01.724.427.00.451.930.233.927901×2402.21.827.530.30.452.033.537.335301×3002.41.930.433.60.452.136.640.54280Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.40.31.212.714.73102×2.50.81.19.811.40.31.213.615.53552×41.01.211.813.50.31.315.718.04752×61.01.212.914.60.31.417.019.35802×101.01.314.916.80.31.419.021.47502×161.01.417.119.10.31.521.424.39802×251.21.521.223.70.31.725.929.013802×351.21.623.125.70.31.828.031.217102×501.41.726.529.20.452.032.536.323702×701.41.930.333.50.452.136.540.531002×951.62.134.938.20.452.341.446.040202×1201.62.238.442.20.452.545.450.148703×1.50.81.19.611.00.31.213.315.33453×2.50.81.110.412.10.31.314.416.44053×41.01.212.614.30.31.316.518.85403×61.01.213.815.50.31.417.920.26603×101.01.315.917.80.31.520.223.09103×161.01.418.220.30.31.622.825.712003×251.21.622.925.40.31.827.830.917603×351.21.724.927.60.451.930.734.422603×501.41.828.531.30.452.034.538.428803×701.42.032.735.90.452.239.043.538003×951.62.237.541.00.452.444.348.948903×1201.62.341.345.30.452.648.553.760703×1501.82.545.849.90.452.853.358.772703×1852.02.750.955.50.453.058.864.989703×2402.22.957.562.40.453.265.872.213504×1.50.81.110.512.10.31.314.416.43954×2.50.81.111.413.10.31.315.417.64654×41.01.213.815.60.31.417.920.36404×61.01.315.317.30.31.519.622.57904×101.01.417.719.70.31.622.225.110704×161.01.520.322.80.31.725.028.114604×251.21.725.528.10.451.931.335.021404×351.21.827.730.50.452.033.737.526704×501.41.931.835.00.452.238.142.136304×701.42.136.339.70.452.443.147.747404×951.62.341.745.70.452.648.954.162904×1201.62.546.250.30.452.853.759.276705×1.50.81.111.413.10.31.315.417.64557×1.50.81.212.614.40.31.316.618.953012×1.50.81.316.818.80.31.521.224.079019×1.50.81.419.922.40.31.624.427.5108027×1.50.81.624.326.90.31.829.232.8146037×1.50.81.727.430.40.451.933.237.019905×2.50.81.212.714.40.31.316.618.95607×2.50.81.213.915.60.31.418.020.365012×2.50.81.418.720.80.31.623.226.297019×2.50.81.522.124.70.31.726.830.01360
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8332ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
250V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed... |
|
|
|
600/1000V LSZH Sheathed,Website:, Armoured ((2-4cores) Application:This range of screened cables drastically reduce interferences from electrical n... |
|
|
|
German Standard Industrial Cables N2XH/ N2XCHApplication and DescriptionN2XH power cables with enhanced resistance to fire are used mostly in areas... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8115ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
供应产品
Same products