0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm2)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.00.31.110.212.12451×61.01.07.28.50.31.110.812.62751×101.01.08.19.50.31.211.913.83551×161.01.19.310.70.31.213.115.04401×251.21.211.513.20.31.315.417.76001×351.21.212.314.10.31.416.518.87201×501.41.314.115.90.31.418.220.69101×701.41.315.817.80.31.520.223.011701×951.61.418.120.20.31.622.625.615101×1201.61.520.022.40.31.724.727.718301×1501.81.622.024.60.31.826.930.121601×1852.01.724.427.00.451.930.233.927901×2402.21.827.530.30.452.033.537.335301×3002.41.930.433.60.452.136.640.54280Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.40.31.212.714.73102×2.50.81.19.811.40.31.213.615.53552×41.01.211.813.50.31.315.718.04752×61.01.212.914.60.31.417.019.35802×101.01.314.916.80.31.419.021.47502×161.01.417.119.10.31.521.424.39802×251.21.521.223.70.31.725.929.013802×351.21.623.125.70.31.828.031.217102×501.41.726.529.20.452.032.536.323702×701.41.930.333.50.452.136.540.531002×951.62.134.938.20.452.341.446.040202×1201.62.238.442.20.452.545.450.148703×1.50.81.19.611.00.31.213.315.33453×2.50.81.110.412.10.31.314.416.44053×41.01.212.614.30.31.316.518.85403×61.01.213.815.50.31.417.920.26603×101.01.315.917.80.31.520.223.09103×161.01.418.220.30.31.622.825.712003×251.21.622.925.40.31.827.830.917603×351.21.724.927.60.451.930.734.422603×501.41.828.531.30.452.034.538.428803×701.42.032.735.90.452.239.043.538003×951.62.237.541.00.452.444.348.948903×1201.62.341.345.30.452.648.553.760703×1501.82.545.849.90.452.853.358.772703×1852.02.750.955.50.453.058.864.989703×2402.22.957.562.40.453.265.872.213504×1.50.81.110.512.10.31.314.416.43954×2.50.81.111.413.10.31.315.417.64654×41.01.213.815.60.31.417.920.36404×61.01.315.317.30.31.519.622.57904×101.01.417.719.70.31.622.225.110704×161.01.520.322.80.31.725.028.114604×251.21.725.528.10.451.931.335.021404×351.21.827.730.50.452.033.737.526704×501.41.931.835.00.452.238.142.136304×701.42.136.339.70.452.443.147.747404×951.62.341.745.70.452.648.954.162904×1201.62.546.250.30.452.853.759.276705×1.50.81.111.413.10.31.315.417.64557×1.50.81.212.614.40.31.316.618.953012×1.50.81.316.818.80.31.521.224.079019×1.50.81.419.922.40.31.624.427.5108027×1.50.81.624.326.90.31.829.232.8146037×1.50.81.727.430.40.451.933.237.019905×2.50.81.212.714.40.31.316.618.95607×2.50.81.213.915.60.31.418.020.365012×2.50.81.418.720.80.31.623.226.297019×2.50.81.522.124.70.31.726.830.01360
Other supplier products
|
|
|
Flame Retardant RS485 Databus Cables Application:Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable ... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8125ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Type 240 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are mainly used as feeder cables for power supply to machinery or longwall supply.Cable... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (3C+3E)CU/XLPE/CUTO/PVC 600/1000V Class 2Application:The cables are designed... |
|
|
|
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:... |
供应产品
Same products