0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)      Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.0901×61.01.07.28.51351×101.01.08.19.51801×161.01.19.310.73151×251.21.211.513.25501×351.21.212.314.17151×501.41.314.115.98301×701.41.315.817.811101×951.61.418.120.214701×1201.61.520.022.421301×1501.81.622.024.624751×1852.01.724.427.028701×2402.21.827.530.331201×3002.41.930.433.64060Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.41452×2.50.81.19.811.41802×41.01.211.813.52602×61.01.212.914.63252×101.01.314.916.84452×161.01.417.119.16302×251.21.521.223.79302×351.21.623.125.712102×501.41.726.529.216302×701.41.930.333.522102×951.62.134.938.230102×1201.62.238.442.236903×1.50.81.19.611.01703×2.50.81.110.412.12103×41.01.212.614.33103×61.01.213.815.53953×101.01.315.917.85903×161.01.418.220.38303×251.21.622.925.412703×351.21.724.927.615403×501.41.828.531.321003×701.42.032.735.928703×951.62.237.541.039103×1201.62.341.345.348003×1501.82.545.849.958103×1852.02.750.955.572903×2402.22.957.562.494404×1.50.81.110.512.12004×2.50.81.111.413.12504×41.01.213.815.63754×61.01.315.317.34954×101.01.417.719.77404×161.01.520.322.810504×251.21.725.528.115804×351.21.827.730.519604×501.41.931.835.025704×701.42.136.339.735304×951.62.341.745.748504×1201.62.546.250.359905×1.50.81.111.413.12207×1.50.81.212.614.428512×1.50.81.316.818.846519×1.50.81.419.922.468027×1.50.81.624.326.996037×1.50.81.727.430.412605×2.50.81.212.714.43107×2.50.81.213.915.637512×2.50.81.418.720.861019×2.50.81.522.124.7895

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

0.6/1 KV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power Control Cables (Single Core)
0.6/1 KV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power Control Cables (Single Core) 0.6/1 kV XLPE Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core)ApplicationThese unarmoured power & cont...
Paper Insulated 11/11KV To AS/NZS
Paper Insulated 11/11KV To AS/NZS Paper Insulated 11/11KV to AS/NZSApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS 1972:2006AS/NZS 1125AS/...
[FA-] MPY, MPYC, MPYCY
[FA-] MPY, MPYC, MPYCY Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 acco...
300/500V Mica+XLPE Or SR Insulated Overall Screened Multicore Fire Resistant Instrumentation Cables
300/500V Mica+XLPE Or SR Insulated Overall Screened Multicore Fire Resistant Instrumentation Cables 300/500V Mica+XLPE or SR Insulated & Overall screened Multicore fire resistant Instrumentation cablesRE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/...
NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813
NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813 NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes