0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.0901×61.01.07.28.51351×101.01.08.19.51801×161.01.19.310.73151×251.21.211.513.25501×351.21.212.314.17151×501.41.314.115.98301×701.41.315.817.811101×951.61.418.120.214701×1201.61.520.022.421301×1501.81.622.024.624751×1852.01.724.427.028701×2402.21.827.530.331201×3002.41.930.433.64060Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.41452×2.50.81.19.811.41802×41.01.211.813.52602×61.01.212.914.63252×101.01.314.916.84452×161.01.417.119.16302×251.21.521.223.79302×351.21.623.125.712102×501.41.726.529.216302×701.41.930.333.522102×951.62.134.938.230102×1201.62.238.442.236903×1.50.81.19.611.01703×2.50.81.110.412.12103×41.01.212.614.33103×61.01.213.815.53953×101.01.315.917.85903×161.01.418.220.38303×251.21.622.925.412703×351.21.724.927.615403×501.41.828.531.321003×701.42.032.735.928703×951.62.237.541.039103×1201.62.341.345.348003×1501.82.545.849.958103×1852.02.750.955.572903×2402.22.957.562.494404×1.50.81.110.512.12004×2.50.81.111.413.12504×41.01.213.815.63754×61.01.315.317.34954×101.01.417.719.77404×161.01.520.322.810504×251.21.725.528.115804×351.21.827.730.519604×501.41.931.835.025704×701.42.136.339.735304×951.62.341.745.748504×1201.62.546.250.359905×1.50.81.111.413.12207×1.50.81.212.614.428512×1.50.81.316.818.846519×1.50.81.419.922.468027×1.50.81.624.326.996037×1.50.81.727.430.412605×2.50.81.212.714.43107×2.50.81.213.915.637512×2.50.81.418.720.861019×2.50.81.522.124.7895
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:, compatible with all known conn... |
|
|
|
Three Core Medium Power Cable to BS 6622
Application:
... |
|
|
|
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control CablesApplication:Th... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9776,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |