0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.0901×61.01.07.28.51351×101.01.08.19.51801×161.01.19.310.73151×251.21.211.513.25501×351.21.212.314.17151×501.41.314.115.98301×701.41.315.817.811101×951.61.418.120.214701×1201.61.520.022.421301×1501.81.622.024.624751×1852.01.724.427.028701×2402.21.827.530.331201×3002.41.930.433.64060Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.41452×2.50.81.19.811.41802×41.01.211.813.52602×61.01.212.914.63252×101.01.314.916.84452×161.01.417.119.16302×251.21.521.223.79302×351.21.623.125.712102×501.41.726.529.216302×701.41.930.333.522102×951.62.134.938.230102×1201.62.238.442.236903×1.50.81.19.611.01703×2.50.81.110.412.12103×41.01.212.614.33103×61.01.213.815.53953×101.01.315.917.85903×161.01.418.220.38303×251.21.622.925.412703×351.21.724.927.615403×501.41.828.531.321003×701.42.032.735.928703×951.62.237.541.039103×1201.62.341.345.348003×1501.82.545.849.958103×1852.02.750.955.572903×2402.22.957.562.494404×1.50.81.110.512.12004×2.50.81.111.413.12504×41.01.213.815.63754×61.01.315.317.34954×101.01.417.719.77404×161.01.520.322.810504×251.21.725.528.115804×351.21.827.730.519604×501.41.931.835.025704×701.42.136.339.735304×951.62.341.745.748504×1201.62.546.250.359905×1.50.81.111.413.12207×1.50.81.212.614.428512×1.50.81.316.818.846519×1.50.81.419.922.468027×1.50.81.624.326.996037×1.50.81.727.430.412605×2.50.81.212.714.43107×2.50.81.213.915.637512×2.50.81.418.720.861019×2.50.81.522.124.7895
Other supplier products
|
|
|
300/500V Mica+XLPE Insulated & LSZH Sheathed Fire Alarm Cables(CU/MICA+XLPE/OS/LSZH 300/500V Class 2 )Application:The cables are designed,Website:,... |
|
|
|
Type W Four-Conductor Round Portable Power Cable 2kVApplicationsThese cables are designed for use with mobile mining equipment such as continuous m... |
|
|
|
German Standard Industrial Cables NAYY-J/NAYY-OApplication and DescriptionNAYY is used in power plants industrial and switching installations,Websi... |
|
|
|
2YSLGCGOEU Signal & Control Cable VDE 0250 Part 812ApplicationsThese control,Website:, signalling and bus cables are used for electric and electron... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed Power Cables (Multicore) CU/XLPE/PVC 450/750V Class 2Application:The cables are mainly used in power... |