0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.0901×61.01.07.28.51351×101.01.08.19.51801×161.01.19.310.73151×251.21.211.513.25501×351.21.212.314.17151×501.41.314.115.98301×701.41.315.817.811101×951.61.418.120.214701×1201.61.520.022.421301×1501.81.622.024.624751×1852.01.724.427.028701×2402.21.827.530.331201×3002.41.930.433.64060Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.41452×2.50.81.19.811.41802×41.01.211.813.52602×61.01.212.914.63252×101.01.314.916.84452×161.01.417.119.16302×251.21.521.223.79302×351.21.623.125.712102×501.41.726.529.216302×701.41.930.333.522102×951.62.134.938.230102×1201.62.238.442.236903×1.50.81.19.611.01703×2.50.81.110.412.12103×41.01.212.614.33103×61.01.213.815.53953×101.01.315.917.85903×161.01.418.220.38303×251.21.622.925.412703×351.21.724.927.615403×501.41.828.531.321003×701.42.032.735.928703×951.62.237.541.039103×1201.62.341.345.348003×1501.82.545.849.958103×1852.02.750.955.572903×2402.22.957.562.494404×1.50.81.110.512.12004×2.50.81.111.413.12504×41.01.213.815.63754×61.01.315.317.34954×101.01.417.719.77404×161.01.520.322.810504×251.21.725.528.115804×351.21.827.730.519604×501.41.931.835.025704×701.42.136.339.735304×951.62.341.745.748504×1201.62.546.250.359905×1.50.81.111.413.12207×1.50.81.212.614.428512×1.50.81.316.818.846519×1.50.81.419.922.468027×1.50.81.624.326.996037×1.50.81.727.430.412605×2.50.81.212.714.43107×2.50.81.213.915.637512×2.50.81.418.720.861019×2.50.81.522.124.7895
Other supplier products
|
|
Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Armoured Instrumentation & Control CablesApplication:The... |
|
|
PiMF/TiMF 150/250V Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Individual Screened Fire Resistant Instrumentation & Control Cables (... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 8775,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9843ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
PiMF/TiMF 150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Individual Screened & Armoured Flame Retardant Instrumentation & Control Cables (... |
供应产品