3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant (Radial Field)

3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)Application:These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Conductor Screen: Semiconducting layer or tape.Insulation: HF-EPR GP5 according to BS 7655 1.2.Insulation Screen: Semiconducting layer or tape +Tinned copper tape.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 15×OD (single core); 20×OD (three core)Temperature Range: -40℃ ~ +90℃Dimensions and Weight3.8/6.6kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×163.01.316.018.00.31.420.223.07901×253.01.317.619.70.31.521.924.99501×353.01.418.720.80.31.523.026.010601×503.01.419.922.30.31.624.427.413201×703.01.521.824.30.31.726.529.616101×953.01.623.726.30.31.828.631.819301×1203.01.625.428.00.31.830.233.922601×1503.01.727.029.80.451.932.836.627601×1853.01.829.032.10.452.035.038.932101×2403.01.931.735.00.452.137.941.939601×3003.02.034.337.60.452.240.645.146601×4003.02.137.641.40.452.444.449.054701×5003.22.341.445.40.452.548.453.666101×6303.22.445.149.20.452.752.457.882303×163.01.832.736.00.452.138.943.326103×253.02.036.539.90.452.242.947.532203×353.02.038.441.90.452.344.949.637003×503.02.241.345.30.452.448.153.343603×703.02.345.349.40.452.652.457.454103×953.02.549.353.90.452.856.862.467103×1203.02.653.157.80.452.960.867.077703×1503.02.756.661.40.453.164.670.991603×1853.02.960.866.10.453.269.176.0104303×2403.03.166.672.20.453.575.582.6128406.35/11kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×163.41.316.818.80.31.521.1248101×253.41.418.620.70.31.522.925.99801×353.41.419.421.90.31.624.027.011101×503.41.520.823.30.31.625.328.413601×703.41.522.625.10.31.727.330.416601×953.41.624.427.10.31.829.333.019701×1203.41.726.329.00.451.932.135.923601×1503.41.727.830.60.452.033.837.628101×1853.41.829.832.90.452.035.839.732601×2403.41.932.535.80.452.238.943.340201×3003.42.035.038.40.452.341.646.147601×4003.42.138.441.90.452.445.149.856101×5003.42.341.845.80.452.548.854.068201×6303.42.445.549.60.452.752.858.284803×163.41.934.537.90.452.140.745.226603×253.42.038.241.60.452.344.749.433103×353.42.140.244.10.452.447.051.739603×503.42.243.047.00.452.550.055.245703×703.42.447.151.30.452.754.459.956103×953.42.551.055.60.452.858.564.568203×1203.42.755.059.80.453.062.969.180703×1503.42.858.463.30.453.166.572.892603×1853.43.062.768.10.453.371.278.1109603×2403.43.268.574.10.453.677.585.2133908.7/15kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×254.51.520.923.40.31.625.428.511501×354.51.521.724.30.31.726.429.612601×504.51.522.925.50.31.727.630.815101×704.51.624.927.50.31.829.833.417701×954.51.726.729.50.451.932.636.322701×1204.51.828.631.40.452.034.638.527301×1504.51.830.133.30.452.136.340.230201×1854.51.932.135.30.452.138.342.334901×2404.52.034.838.20.452.241.245.742601×3004.52.137.340.80.452.444.148.748101×4004.52.240.744.60.452.547.652.461601×5004.52.444.148.20.452.651.356.673301×6304.52.547.852.00.452.855.360.888003×254.52.243.147.10.452.550.155.436103×354.52.345.249.20.452.652.357.745103×504.52.447.952.10.452.755.360.852103×704.52.652.156.70.452.959.865.963903×954.52.755.960.70.453.063.870.176603×1204.52.959.964.90.453.268.275.188103×1504.53.063.368.70.453.371.878.8100703×1854.53.267.673.20.453.576.583.711420
Other supplier products
|
|
Type SHD-GC Three-Conductor Portable Power Cable, CPE Jacket 2kV ICEA S-75-381 |
Type SHD-GC Three-Conductor Portable Power Cable,Website:, CPE Jacket 2kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applica... |
|
|
N2XRY |
German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts ... |
|
|
PE Insulated, LSZH Sheathed, Overall Screened And Armoured Instrumentation Cables (Multicore) |
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multicore)RE-2Y(St)HSWAH 90°C / 500VSTANDARDSBasic design... |
|
|
P5 Or P5/P12 BFOU 0.6/1KV NEK606 Cable |
P5 or P5/P12 BFOU 0.6/1KV Fire Resistant NEK606 Power cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke,halog... |
|
|
3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant (Radial Field) |
3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)Applicatio... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |