3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant (Radial Field)

3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)Application:These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Conductor Screen: Semiconducting layer or tape.Insulation: HF-EPR GP5 according to BS 7655 1.2.Insulation Screen: Semiconducting layer or tape +Tinned copper tape.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 15×OD (single core); 20×OD (three core)Temperature Range: -40℃ ~ +90℃Dimensions and Weight3.8/6.6kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×163.01.316.018.00.31.420.223.07901×253.01.317.619.70.31.521.924.99501×353.01.418.720.80.31.523.026.010601×503.01.419.922.30.31.624.427.413201×703.01.521.824.30.31.726.529.616101×953.01.623.726.30.31.828.631.819301×1203.01.625.428.00.31.830.233.922601×1503.01.727.029.80.451.932.836.627601×1853.01.829.032.10.452.035.038.932101×2403.01.931.735.00.452.137.941.939601×3003.02.034.337.60.452.240.645.146601×4003.02.137.641.40.452.444.449.054701×5003.22.341.445.40.452.548.453.666101×6303.22.445.149.20.452.752.457.882303×163.01.832.736.00.452.138.943.326103×253.02.036.539.90.452.242.947.532203×353.02.038.441.90.452.344.949.637003×503.02.241.345.30.452.448.153.343603×703.02.345.349.40.452.652.457.454103×953.02.549.353.90.452.856.862.467103×1203.02.653.157.80.452.960.867.077703×1503.02.756.661.40.453.164.670.991603×1853.02.960.866.10.453.269.176.0104303×2403.03.166.672.20.453.575.582.6128406.35/11kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×163.41.316.818.80.31.521.1248101×253.41.418.620.70.31.522.925.99801×353.41.419.421.90.31.624.027.011101×503.41.520.823.30.31.625.328.413601×703.41.522.625.10.31.727.330.416601×953.41.624.427.10.31.829.333.019701×1203.41.726.329.00.451.932.135.923601×1503.41.727.830.60.452.033.837.628101×1853.41.829.832.90.452.035.839.732601×2403.41.932.535.80.452.238.943.340201×3003.42.035.038.40.452.341.646.147601×4003.42.138.441.90.452.445.149.856101×5003.42.341.845.80.452.548.854.068201×6303.42.445.549.60.452.752.858.284803×163.41.934.537.90.452.140.745.226603×253.42.038.241.60.452.344.749.433103×353.42.140.244.10.452.447.051.739603×503.42.243.047.00.452.550.055.245703×703.42.447.151.30.452.754.459.956103×953.42.551.055.60.452.858.564.568203×1203.42.755.059.80.453.062.969.180703×1503.42.858.463.30.453.166.572.892603×1853.43.062.768.10.453.371.278.1109603×2403.43.268.574.10.453.677.585.2133908.7/15kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×254.51.520.923.40.31.625.428.511501×354.51.521.724.30.31.726.429.612601×504.51.522.925.50.31.727.630.815101×704.51.624.927.50.31.829.833.417701×954.51.726.729.50.451.932.636.322701×1204.51.828.631.40.452.034.638.527301×1504.51.830.133.30.452.136.340.230201×1854.51.932.135.30.452.138.342.334901×2404.52.034.838.20.452.241.245.742601×3004.52.137.340.80.452.444.148.748101×4004.52.240.744.60.452.547.652.461601×5004.52.444.148.20.452.651.356.673301×6304.52.547.852.00.452.855.360.888003×254.52.243.147.10.452.550.155.436103×354.52.345.249.20.452.652.357.745103×504.52.447.952.10.452.755.360.852103×704.52.652.156.70.452.959.865.963903×954.52.755.960.70.453.063.870.176603×1204.52.959.964.90.453.268.275.188103×1504.53.063.368.70.453.371.878.8100703×1854.53.267.673.20.453.576.583.711420
Other supplier products
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (Multicore)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/SWA/PVC 600/1000V Class ... |
|
|
|
0.6/1 kV XLPE Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core)ApplicationThese unarmoured power & cont... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 8775,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
|
S12 RU(c) 250 V EPR insulation,Website:, SHF2 sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke ... |
|
|
|
3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)Applicatio... |