3.6 6kV 6 10kV 8.7 15kV IEC60092 SHF2 Sheathed MV Cable

3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1)Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath)ApplicationThese armoured MV cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352.These cables are flame retardant, low smoke& halogen free.StandardsIEC 60092-350/351/354/359IEC 60332-1IEC 60332-3-22IEC 60754-1/2IEC 61034ConstructionConductorsClass 2 stranded copper conductor.Conductor ScreenSemi-conducting layer (tape/compound).InsulationXLPE.Insulation ScreenSemi-conducting layer (tape/compound).Metallic ScreenCopper tapeInner SheathLSOH (SHF1).ArmourCopper wire braid or galvanized steel wire braid.Outer SheathLSOH (SHF1). SHF2 can be offered upon request.Core IdentificationColoured tape shall be inserted under metallic screen.3core: Red, Yellow, Blue.Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 12×OD (single core); 9×OD (three core)Temperature Range: -30℃ ~ +80℃Dimensions and Weight3.6/6kVPart No.ConstructionNo. ofcores×Crosssection(mm²)NominalInsulation Thickness mmNominal Sheath Thickness mmNominalOverall Diameter mmNominal Weight kg/kmInnerOuter3.6/6KV-1C101×102.51.31.019.25603.6/6KV-1C161×162.51.31.020.16503.6/6KV-1C251×252.51.41.121.88003.6/6KV-1C351×352.51.41.123.09403.6/6KV-1C501×502.51.51.224.711203.6/6KV-1C701×702.51.61.226.713903.6/6KV-1C951×952.51.61.328.817203.6/6KV-1C1201×1202.51.71.330.620203.6/6KV-1C1501×1502.51.81.332.423503.6/6KV-1C1851×1852.51.81.434.427803.6/6KV-1C2401×2402.62.01.538.435803.6/6KV-1C3001×3002.82.11.641.643103.6/6KV-1C4001×4003.02.21.745.854403.6/6KV-1C5001×5003.22.41.749.364503.6/6KV-1C6301×6303.22.51.954.181103.6/6KV-3C103×102.51.91.436.317103.6/6KV-3C163×162.52.01.538.820303.6/6KV-3C253×252.52.11.642.025003.6/6KV-3C353×352.52.21.644.829503.6/6KV-3C503×502.52.31.748.035103.6/6KV-3C703×702.52.51.852.544203.6/6KV-3C953×952.52.61.957.054703.6/6KV-3C1203×1202.52.82.061.064803.6/6KV-3C1503×1502.52.92.164.975403.6/6KV-3C1853×1852.53.12.269.389403.6/6KV-3C2403×2402.63.32.476.4111806/10kVPart No.ConstructionNo. ofcores×Crosssection(mm²)NominalInsulation Thickness mmNominal Sheath Thickness mmNominalOverall Diameter mmNominal Weight kg/kmInnerOuter6/10KV-1C161×163.41.41.122.37506/10KV-1C251×253.41.51.123.88906/10KV-1C351×353.41.51.225.210406/10KV-1C501×503.41.61.226.712206/10KV-1C701×703.41.61.228.514806/10KV-1C951×953.41.71.330.818306/10KV-1C1201×1203.41.81.332.621406/10KV-1C1501×1503.41.81.434.424706/10KV-1C1851×1853.41.91.436.929906/10KV-1C2401×2403.42.01.540.036806/10KV-1C3001×3003.42.11.642.843906/10KV-1C4001×4003.42.31.746.855106/10KV-1C5001×5003.42.41.849.964806/10KV-1C6301×6303.42.51.954.581306/10KV-3C163×163.42.11.643.123506/10KV-3C253×253.42.21.746.328406/10KV-3C353×353.42.31.749.133106/10KV-3C503×503.42.51.852.539106/10KV-3C703×703.42.61.956.848206/10KV-3C953×953.42.82.061.459306/10KV-3C1203×1203.42.92.165.369406/10KV-3C1503×1503.43.12.269.380506/10KV-3C1853×1853.43.22.373.694606/10KV-3C2403×2403.43.42.580.2116808.7/15kVPart No.ConstructionNo. ofcores×Crosssection(mm²)NominalInsulation Thickness mmNominal Sheath Thickness mmNominalOverall Diameter mmNominal Weight kg/kmInnerOuter8.7/15KV-1C251×254.51.61.226.410308.7/15KV-1C351×354.51.61.227.611808.7/15KV-1C501×504.51.71.329.313708.7/15KV-C701×704.51.71.331.116508.7/15KV-1C951×954.51.81.433.420108.7/15KV-1C1201×1204.51.91.435.724108.7/15KV-1C1501×1504.51.91.537.527608.7/15KV-1C1851×1854.52.01.539.532008.7/15KV-1C2401×2404.52.11.642.639108.7/15KV-1C3001×3004.52.21.645.246108.7/15KV-1C4001×4004.52.31.749.057308.7/15KV-1C5001×5004.52.51.852.367408.7/15KV-1C6301×6304.52.61.956.984008.7/15KV-3C253×254.52.41.851.633008.7/15KV-3C353×354.52.51.954.638208.7/15KV-3C503×504.52.61.957.644008.7/15KV-3C703×704.52.82.062.153708.7/15KV-3C953×954.53.02.267.065508.7/15KV-3C1203×1204.53.12.370.875808.7/15KV-3C1503×1504.53.22.374.586808.7/15KV-3C1853×1854.53.42.579.2101808.7/15KV-3C2403×2404.53.62.685.612420
Other supplier products
|
|
XHHW-2, AL Armor, 600V Type MC |
UL Industrial Cables XHHW-2,Website:, AL armor, 600V Type MCApplication and Description600 Volt Type MC Cable is for use in aerial installations, d... |
|
|
Belden8342 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
NTSWOEU 0.6/1kV E-Loader Cable VDE 0250 Part 813 |
NTSWOEU 0.6/1kV E-Loader Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of mobile machines under extremelyhigh mechani... |
|
|
Type 275 1.1/1.1KV To AS/NZS 1802 |
Type 275 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used as a flexible feeder for shuttle cars and pump. Earth cores designed to r... |
|
|
P7 Or P7/P14 BFOU 6/10kV NEK606 Cable |
P7 or P7/P14 BFOU 6/10kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke, halogen ... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |