H07RN8-F

VDE Standard Industrial Cables H07RN8-FApplication and DescriptionThese cables particularly for use in fresh water up to 10 m depth with a maximum water temperature up to 40°C ,Website:, such as tde onnection of submersible pumps or similar applications.Not suitable for underwater power transmission or installation in a watercourse, or where it is possible that mechanical damage might occur and cause a hazard.Indirect underground installation is allowed provided tdat there is mechanically protection of the cables.These cables are manufactured according to the Standard and Approval CEI 20- 19/16 (CENELEC HD 22.16). It is the only cable that thVDEe installation Standard and Approval CEI 64-8 at section 702 allows for installation in swimming pools and fountains.For connections liable to moderate mechanical stresses, i.e. industrial or agricultural workshop apparatus, large boilers, heater plates, electric tools such as drills and disk saws, electric appliances, portable motors and generators on building sites; also for fixed installations along floors or shelving on temporary job sites, for connecting structural elements in lifting apparatus, machinery, etc.Suitable for applications up to 1000 V for adequately protected fixed installations ( i.e. inside pipes or equipment) as well as for rotor connections to lifting apparatus motors. They are Ozone, UV & weatder resistantStandard and ApprovalHD22.16 S1, VDE-0282 Part-16, CEI 20-19 p.16, CE low voltage directive 73/23/EEC & 93/68/EEC., ROHS compliantCable Construction- Fine bare copper strands- Strands to VDE-0295 Class-5, IEC 60228 Class-5- Rubber core insulation EI4 to VDE-0282 Part-1- Color code VDE-0293-308 and HD 186- Polychloroprene rubber (neoprene) jacket EM2Technical Characteristics- Working voltage: 450/750 volts- Test voltage: 2500 volts- Flexing bending radius: 6.0 x Ø- Fixed bending radius: 4.0 x Ø- Flexing Temperature: -25º C to +60º C- Fixed Temperature: -40º C to +60º C- Max Water Temperature: +40º C- Short circuit temperature: +250 º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETER MM MIN-MAXNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KM17(32/32)2 x 10.81.37./32)3 x 10.81.48.3-10./32)4 x 10.81.59.2-11./30)1 x 1.50.81.45.7-7.114.45916(30/30)2 x 1.50.81.58.5-11./30)3 x 1.50.81.69.2-11./30)4 x 1.50.81.710.2-13./30)5 x 1.50.81.811.2-14./30)7 x 1.50.82.614.5-17./30)12 x 1.50.82.917.6-22./30)19 x 1.50.83.220.7-26./30)24 x 1.50.83.524.3-30./30)1 x 2.50.91.46.3-7.9247214(50/30)2 x 2.50.91.710.2-13./30)3 x 2.50.91.810.9-14./30)4 x 2.50.91.912.1-15./30)5 x 2.50.9213.3-17./30)7 x 2.50.92.816.5-20./30)12 x 2.50.93.120.6-26./30)19 x 2.50.93.525.5-31./30)24 x 2.50.93.928.8-36./28)1 x 411.57.2-9.0389912(56/28)2 x 411.811.8-15./28)3 x 411.912.7-16./28)4 x 41214.0-17./28)5 x 412.215.6-19./28)7 x 413.118.2-21./28)1 x 611.67.9-9./28)3 x 612.114.1-18./28)4 x 612.315.7-20./28)5 x 61.23.617.5-22./26)1 x 101.21.89.5-11.9962308(80/26)3 x 101.23.319.1-24./26)4 x 101.23.420.9-26./26)5 x 101.23.622.9-29./26)1 x 161.21.910.8-13./26)3 x 161.23.521.8-27./26)4 x 161.23.623.8-30./26)5 x 161.23.926.4-33.376816804 (200/26)1 x251.4212.7-15.82404504 (200/26)4 x 251.44.128.9-36.696019954 (200/26)5 x 251.44.432.0-40.4120024702 (280/26)1 x 351.42.214.3-17.93366052 (280/26)3 x 351.44.129.3-37.1100819002 (280/26)4 x 351.44.432.5-41.1134426452 (280/26)5 x 351.44.737.0-45.0168028101 (400/26)1 x 501.62.416.5-20.64808251 (400/26)4 x 501.64.837.7-47.5192036351 (400/26)5 x 501.65.140.0-50.8240040502/0 (356/24)1 x 701.62.618.6-23.367210902/0 (356/24)4 x 701.65.242.7-54.0268848303/0 (485/24)1 x 951.82.820.8-26.091214053/0 (485/24)4 x 951.85.948.4-61.0364863204/0 (614/24)1x 1201.8322.8-28.6115217464/0 (614/24)4 x 1201.8653.0-66. MCM (765/24)1 x 15023.225.2-31. MCM (765/24)4 x 15026.458.0-73. MCM (944/24)1 x 1852.23.427.6-34. MCM (944/24)4 x 1852.26.864.0-80. MCM (1221/24)1x 2402.43.530.6-38.323.42956500 MCM (1221/24)4x 2402.47.272.0-90. x 3002.63.633.5-41.928803479
Other supplier products
|
|
(N)SHOEU 0.6/1kV Flexible Cable VDE 0250 Part 812 |
(N)SHOEU 0.6/1kV Flexible cable VDE 0250 Part 812ApplicationsThese cables are designed for use in open cast miningfactories for laying of excavator... |
|
|
RG58 Armoured NEK606 Coaxial Cable |
RG58 Armoured Coaxial Cable NEK 606Applications :These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine ... |
|
|
P5 Or P5/P12 BFOU 0.6/1KV NEK606 Cable |
P5 or P5/P12 BFOU 0.6/1KV Fire Resistant NEK606 Power cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke,halog... |
|
|
Type SHD-GC Three-Conductor Round Portable Power Cable, CPE Jacket 8kV ICEA S-75-381 |
Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, CPE Jacket 8kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for a... |
|
|
XHHW/XLPO, Type TC |
UL Industrial Cables XHHW/XLPO,Website:, Type TC ControlApplication and DescriptionXHHW XLPO type TC Control Cable is for use in industrial power o... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |