.

H07RN8-F

VDE Standard Industrial Cables H07RN8-FApplication and DescriptionThese cables particularly for use in fresh water up to 10 m depth with a maximum water temperature up to 40°C ,Website:, such as tde onnection of submersible pumps or similar applications.Not suitable for underwater power transmission or installation in a watercourse, or where it is possible that mechanical damage might occur and cause a hazard.Indirect underground installation is allowed provided tdat there is mechanically protection of the cables.These cables are manufactured according to the Standard and Approval CEI 20- 19/16 (CENELEC HD 22.16). It is the only cable that thVDEe installation Standard and Approval CEI 64-8 at section 702 allows for installation in swimming pools and fountains.For connections liable to moderate mechanical stresses, i.e. industrial or agricultural workshop apparatus, large boilers, heater plates, electric tools such as drills and disk saws, electric appliances, portable motors and generators on building sites; also for fixed installations along floors or shelving on temporary job sites, for connecting structural elements in lifting apparatus, machinery, etc.Suitable for applications up to 1000 V for adequately protected fixed installations ( i.e. inside pipes or equipment) as well as for rotor connections to lifting apparatus motors. They are Ozone, UV & weatder resistantStandard and ApprovalHD22.16 S1, VDE-0282 Part-16, CEI 20-19 p.16, CE low voltage directive 73/23/EEC & 93/68/EEC., ROHS compliantCable Construction- Fine bare copper strands- Strands to VDE-0295 Class-5, IEC 60228 Class-5- Rubber core insulation EI4 to VDE-0282 Part-1- Color code VDE-0293-308 and HD 186- Polychloroprene rubber (neoprene) jacket EM2Technical Characteristics- Working voltage: 450/750 volts- Test voltage: 2500 volts- Flexing bending radius: 6.0 x Ø- Fixed bending radius: 4.0 x Ø- Flexing Temperature: -25º C to +60º C- Fixed Temperature: -40º C to +60º C- Max Water Temperature: +40º C- Short circuit temperature: +250 º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETER MM MIN-MAXNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KM17(32/32)2 x 10.81.37./32)3 x 10.81.48.3-10./32)4 x 10.81.59.2-11./30)1 x 1.50.81.45.7-7.114.45916(30/30)2 x 1.50.81.58.5-11./30)3 x 1.50.81.69.2-11./30)4 x 1.50.81.710.2-13./30)5 x 1.50.81.811.2-14./30)7 x 1.50.82.614.5-17./30)12 x 1.50.82.917.6-22./30)19 x 1.50.83.220.7-26./30)24 x 1.50.83.524.3-30./30)1 x 2.50.91.46.3-7.9247214(50/30)2 x 2.50.91.710.2-13./30)3 x 2.50.91.810.9-14./30)4 x 2.50.91.912.1-15./30)5 x 2.50.9213.3-17./30)7 x 2.50.92.816.5-20./30)12 x 2.50.93.120.6-26./30)19 x 2.50.93.525.5-31./30)24 x 2.50.93.928.8-36./28)1 x 411.57.2-9.0389912(56/28)2 x 411.811.8-15./28)3 x 411.912.7-16./28)4 x 41214.0-17./28)5 x 412.215.6-19./28)7 x 413.118.2-21./28)1 x 611.67.9-9./28)3 x 612.114.1-18./28)4 x 612.315.7-20./28)5 x 61.23.617.5-22./26)1 x 101.21.89.5-11.9962308(80/26)3 x 101.23.319.1-24./26)4 x 101.23.420.9-26./26)5 x 101.23.622.9-29./26)1 x 161.21.910.8-13./26)3 x 161.23.521.8-27./26)4 x 161.23.623.8-30./26)5 x 161.23.926.4-33.376816804 (200/26)1 x251.4212.7-15.82404504 (200/26)4 x 251.44.128.9-36.696019954 (200/26)5 x 251.44.432.0-40.4120024702 (280/26)1 x 351.42.214.3-17.93366052 (280/26)3 x 351.44.129.3-37.1100819002 (280/26)4 x 351.44.432.5-41.1134426452 (280/26)5 x 351.44.737.0-45.0168028101 (400/26)1 x 501.62.416.5-20.64808251 (400/26)4 x 501.64.837.7-47.5192036351 (400/26)5 x 501.65.140.0-50.8240040502/0 (356/24)1 x 701.62.618.6-23.367210902/0 (356/24)4 x 701.65.242.7-54.0268848303/0 (485/24)1 x 951.82.820.8-26.091214053/0 (485/24)4 x 951.85.948.4-61.0364863204/0 (614/24)1x 1201.8322.8-28.6115217464/0 (614/24)4 x 1201.8653.0-66. MCM (765/24)1 x 15023.225.2-31. MCM (765/24)4 x 15026.458.0-73. MCM (944/24)1 x 1852.23.427.6-34. MCM (944/24)4 x 1852.26.864.0-80. MCM (1221/24)1x 2402.43.530.6-38.323.42956500 MCM (1221/24)4x 2402.47.272.0-90. x 3002.63.633.5-41.928803479

在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Fire resistant RG6 A/U Coaxial cables RG6 A/U FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation mon...
Type W Two-Conductor Flat Portable Power Cable 2kVApplicationsThese flat parallel cables are designed for use on DCmining equipment,Website:, such ...
Cat 5e S/FTP 0.22mm2 IEC60092ApplicationThese Cat5e S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support...
German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts ...
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections bet...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes