600 1000V XLPE Insulated, PVC Sheathed, Double Steel Tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (3 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, normal stranded or compact stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Filler, binder and inner covering: PP, PET, PVCArmouring: Double steel tapeOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 10x Overall DiameterCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionPhasesNeutralNominal Diameter Overall ConducrtorNominal Insulation ThicknessNominal Steel Tape ThicknessNominal Sheath ThicknessNominal Overall DiatemerApprox. No./ WeightNo./ Weight Nominal Diameter of StrandsNo./ Nominal Diameter of StrandsPha.Neu.Pha.Neu.mm2No/mmNo/mmmmmmmmmmmmmmmmKg/km3x10+1x67/1.357/1.043.752.900.70.70.21.820.17403x16+1x107/1.707/1.354.753.750.70.70.21.822.51,0043x25+2x167/2.147/1.705.854.750.90.70.21.825.81,4213x35+1x167/2.527/1.706.904.750.90.70.21.827.71,7453x35+1x257/2.527/2.146.905.850.90.90.21.828.61,8643x50+1x2519/1.787/2.148.155.851.00.90.21.831.32,3583x50+1x3519/1.787/2.528.156.901.00.90.21.932.02.723x70+1x3519/2.147/2.529.756.90I.10.90.22.035.931663x70+1x5019/2.1419/1.789.758.15I.11.00.22.036.83.3413x95+1x5019/2.5219/1.7811.48.15I.11.00.52.141.44,6113x120+1x7037/2.0319/2.1412.89.751.2I.10.52.345.656823x150+1x9537/2.2519/2.5214.311.41.4I.10.52.450.87,0723x150+1x12037/2.2537/2.0314.312.81.41.20.52.551.87,3573x185+1x9537/2.5219/2.5215.911.41.6I.10.52.654.78,3483x185+1x12037/2.5237/2.0315.912.81.61.20.52.655.886383x240+1x12061/2.2537/2.0318.212.81.71.20.52.761.010,6603x240+1x15061/2.2537/2.2518.214.31.71.40.52.862.2110243x300+1x15061/2.5237/2.2520.414.31.81.40.52.966.812,8093x300+1x18561/2.5237/2.5220.415.91.81.60.53.068.113,256Notes:1) *All conductors in accordance with lEC 60228. Compact shape (Com.) or non-compact depending on order.2) Beside above list we can also provide others size depend on customer's requirement.Electrical PropertiesNo. of Core X Cross SectionConductorMax.DC resistance of conductor ConducrtorNo./Nominal Diameter of StrandsNo./Nominal Diameter of StrandsPha.Neu.Pha.Neu.mm2No/mmNo/mmmmmmΩ/kmΩ/km3x10+1x67/1.357/1.043.752.901.833.083x16+1x107/1.707/1.354.753.751.151.833x25+2x167/2.147/1.705.854.750.7271.153x35+1x167/2.527/1.706.904.750.5241.153x35+1x257/2.527/2.146.905.850.5240.7273x50+1x2519/1.787/2.148.155.850.3870.7273x50+1x3519/1.787/2.528.156.900.3870.5243x70+1x3519/2.147/2.529.756.9002680.5243x70+1x5019/2.1419/1.789.758.1502680.3873x95+1x5019/2.5219/1.7811.48.150.1930.3873x120+1x7037/2.0319/2.1412.89.750.1530.2683x150+1x9537/2.2519/2.5214.311.40.1240.1933x150+1x12037/2.2537/2.0314.312.80.1240.1533x185+1x9537/2.5219/2.5215.911.40.09910.1933x185+1x12037/2.5237/2.0315.912.80.09910.1533x240+1x12061/2.2537/2.0318.212.80.07540.1533x240+1x15061/2.2537/2.2518.214.30.07540.1243x300+1x15061/2.5237/2.2520.414.30.06010.1243x300+1x18561/2.5237/2.5220.415.90.06010.0991Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm2AAAAAAAAVoltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m67.97.96.87.96.5104.74.74.04.73.9162.92.92.52.92.6rxzrxz251.8501.3500.1601.9001.6000.1401.6501.9001.600351.3501.3500.1551.3501.1500.1351.1501.3501.200500.9800.9900.1551.0000.8600.1350.8701.0000.870700.6700.6700.1500.6900.5900.1300.6000.6900.610950.4900.5000.1500.5200.4300.1300.4500.5200.4501200.3900.4000.1450.4200.3400.1300.3700.4200.3601500.3100.3200.1450.3500.2800.1250.3000.3500.3001850.2500.2600.1450.2900.2200.1250.2600.2900.2502400.1950.2000.1400.2400.1750.1250.2100.2400.2103000.1550.1600.1400.2100.1400.1200.1850.2100.1904000.1200.1300.1400.1900.1150.1200.1650.1900.180
Other supplier products
|
|
Belden8115 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8115ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
300V Mica+LSZH Insulated LSZH Sheathed Fire Alarm Cables |
300V Mica+LSZH Insulated & LSZH Sheathed Fire Alarm CablesJE-H(St)H…Bd FE180 E90. (CU/MICA+LSZH/OS/LSZH 300V Class 1 )JE-H(St)H…Bd FE180 E90 BMK* (... |
|
|
NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812 |
NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812ApplicationsThese cables are designed for the connection of mobile equipment... |
|
|
N2XCY |
German Standard Industrial Cables N2XCYApplication and DescriptionIn indoor installation,Website:, in cable ducts outdoor and underground for power... |
|
|
LiYCYCY |
German Standard Industrial Cables LiYCYCYApplication and DescriptionLiYCYCY braiding cable is for use in flexible or stationary applications under ... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |