.

600 1000V XLPE Insulated, PVC Sheathed, Double Steel Tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (3 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, normal stranded or compact stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Filler, binder and inner covering: PP, PET, PVCArmouring: Double steel tapeOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 10x Overall DiameterCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionPhasesNeutralNominal Diameter Overall ConducrtorNominal Insulation ThicknessNominal Steel Tape ThicknessNominal Sheath ThicknessNominal Overall DiatemerApprox. No./ WeightNo./ Weight Nominal Diameter of StrandsNo./ Nominal Diameter of StrandsPha.Neu.Pha.Neu.mm2No/mmNo/mmmmmmmmmmmmmmmmKg/km3x10+1x67/1.357/1.043.752.900.70.70.21.820.17403x16+1x107/1.707/1.354.753.750.70.70.21.822.51,0043x25+2x167/2.147/1.705.854.750.90.70.21.825.81,4213x35+1x167/2.527/1.706.904.750.90.70.21.827.71,7453x35+1x257/2.527/2.146.905.850.90.90.21.828.61,8643x50+1x2519/1.787/2.148.155.851.00.90.21.831.32,3583x50+1x3519/1.787/2.528.156.901.00.90.21.932.02.723x70+1x3519/2.147/2.529.756.90I.10.90.22.035.931663x70+1x5019/2.1419/1.789.758.15I.11.00.22.036.83.3413x95+1x5019/2.5219/1.7811.48.15I.11.00.52.141.44,6113x120+1x7037/2.0319/2.1412.89.751.2I.10.52.345.656823x150+1x9537/2.2519/2.5214.311.41.4I.10.52.450.87,0723x150+1x12037/2.2537/2.0314.312.81.41.20.52.551.87,3573x185+1x9537/2.5219/2.5215.911.41.6I.10.52.654.78,3483x185+1x12037/2.5237/2.0315.912.81.61.20.52.655.886383x240+1x12061/2.2537/2.0318.212.81.71.20.52.761.010,6603x240+1x15061/2.2537/2.2518.214.31.71.40.52.862.2110243x300+1x15061/2.5237/2.2520.414.31.81.40.52.966.812,8093x300+1x18561/2.5237/2.5220.415.91.81.60.53.068.113,256Notes:1) *All conductors in accordance with lEC 60228. Compact shape (Com.) or non-compact depending on order.2) Beside above list we can also provide others size depend on customer's requirement.Electrical PropertiesNo. of Core X Cross SectionConductorMax.DC resistance of conductor ConducrtorNo./Nominal Diameter of StrandsNo./Nominal Diameter of StrandsPha.Neu.Pha.Neu.mm2No/mmNo/mmmmmmΩ/kmΩ/km3x10+1x67/1.357/1.043.752.901.833.083x16+1x107/1.707/1.354.753.751.151.833x25+2x167/2.147/1.705.854.750.7271.153x35+1x167/2.527/1.706.904.750.5241.153x35+1x257/2.527/2.146.905.850.5240.7273x50+1x2519/1.787/2.148.155.850.3870.7273x50+1x3519/1.787/2.528.156.900.3870.5243x70+1x3519/2.147/2.529.756.9002680.5243x70+1x5019/2.1419/1.789.758.1502680.3873x95+1x5019/2.5219/1.7811.48.150.1930.3873x120+1x7037/2.0319/2.1412.89.750.1530.2683x150+1x9537/2.2519/2.5214.311.40.1240.1933x150+1x12037/2.2537/2.0314.312.80.1240.1533x185+1x9537/2.5219/2.5215.911.40.09910.1933x185+1x12037/2.5237/2.0315.912.80.09910.1533x240+1x12061/2.2537/2.0318.212.80.07540.1533x240+1x15061/2.2537/2.2518.214.30.07540.1243x300+1x15061/2.5237/2.2520.414.30.06010.1243x300+1x18561/2.5237/2.5220.415.90.06010.0991Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm2AAAAAAAAVoltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m67.97.96.87.96.5104.74.74.04.73.9162.92.92.52.92.6rxzrxz251.8501.3500.1601.9001.6000.1401.6501.9001.600351.3501.3500.1551.3501.1500.1351.1501.3501.200500.9800.9900.1551.0000.8600.1350.8701.0000.870700.6700.6700.1500.6900.5900.1300.6000.6900.610950.4900.5000.1500.5200.4300.1300.4500.5200.4501200.3900.4000.1450.4200.3400.1300.3700.4200.3601500.3100.3200.1450.3500.2800.1250.3000.3500.3001850.2500.2600.1450.2900.2200.1250.2600.2900.2502400.1950.2000.1400.2400.1750.1250.2100.2400.2103000.1550.1600.1400.2100.1400.1200.1850.2100.1904000.1200.1300.1400.1900.1150.1200.1650.1900.180


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

CAN BUS CABLES 120ΩApplicationThese cables are dedicated to the shipbuilding industry.StandardsIEC 60092-350/351/352/353/359/370/376IEC 60332-1-2IE...
Type SHD-GC Three-Conductor Portable Power Cable,Website:, CPE Jacket 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applica...
S12 RU(c) 250 V EPR insulation,Website:, SHF2 sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke ...
F6 AICI NEK606 optical fibre cableApplications :These optical fibre cables are fire resistant,Website:, flame retardant, low smoke and halogen free...
P2 or P2/P9 RFOU/TFOU 3.6/6KV NEK606 MV cableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, us...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes