300/500V XLPE Insulated LSZH Sheathed Flame Retardant Power Cables (single Core)

300/500V XLPE Insulated LSZH sheathed Flame retardant Power Cables (single core) Application:The cables are mainly used in power stations,Website:, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.Standard:Basic design to IEC 60502-1APPLICATIONFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING 300/500VCABLE CONSTRUCTIONConductor:1.Plain annealed copper wire, stranded according to IEC(EN) 60228 class2.Insulation: Extruded cross-linked XLPE compound.3.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE 250°C in short-circuit for 5s max. Minimum bending radius: 6 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable) SWB Steel wire braidCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Overall DiameterApprox. WeightNoxmm2No./mmmmmmkg/km1x1.57/0.530.503.8271x2.57/0.670.504.2371x4.07/0.850.504.854Electrical PROPERTIESConductor Operating Temperature : 90°C Ambient Temperature : 30°C Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

450/750V 600/1000V Mica+LSZH Insulated Power Cables (Single Core)
450/750V 600/1000V Mica+LSZH Insulated Power Cables (Single Core) 450/750V  600/1000V Mica+LSZH Insulated fire resistant Power Cables (Single Core)(CU/MGT+LSZH 450/750V Class 2)(CU/MGT+LSZH 600/1000V Class 2)Appli...
Single Core Cables To IEC 60502
Single Core Cables To IEC 60502 Single Core Medium Cable to IEC 60502-2 Application: ...
(N)TSCGEWOEU Medium-Voltage Reeling Cable Without Fibre Optics
(N)TSCGEWOEU Medium-Voltage Reeling Cable Without Fibre Optics (N)TSCGEWOEU Medium-Voltage Reeling Cable Without Fibre OpticsApplicationsThese cables are used for connection of large mobile equipment such asexc...
Belden8110
Belden8110 Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8110ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl...
RG59 Armoured NEK606 Coaxial Cable
RG59 Armoured NEK606 Coaxial Cable 75Ω RG59 Armoured Coaxial Cable NEK606Applications :These 75Ω coaxial cables are suitable for installation on board of ships and other indoor mari...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes