.

600/1000V LSZH Sheathed, Overall Screened & Armoured (single Core)

600/1000V LSZH Sheathed,Website:, Overall screened & Armoured (single core)Application:This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors.Standard:Basic design to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING600/1000VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound. Inner sheath(optional): LSZH Compound Armouring(optional): Aluminium WireOuter Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODE Insulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C250°C in short-circuit for 5s max. Minimum bending radius: 8 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter Of StrandsNominal Insulation ThicknessNominal Sheath ThicknessDiameter Under ScreenDiameter Over Inner SheathArmour Wire DiameterNominal Overall DiameterApprox. WeightNoxmm2No./mmmmmmkg/kmmmmmmmkg/km1x7019/2.141.11.815.217.620.123.914001x9519/2.521.11.817.119.522.025.817001x12037/2.031.21.819.020.824.027.820001x15037/2.251.41.821.022.826.029.824001x18537/2.521.61.823.225.028.232.028001x24061/2.251.71.926.127.931.135.135001x30061/2.521.82.028.730.533.737.942001x40061/2.852.02.132.534.338.342.754001x50061/3.202.22.236.037.841.846.465001x630127/2.522.42.340.442.246.251.082001x800127/2.852.62.545.547.352.357.5104001x1000127/3.202.82.750.452.257.262.413000Electrical PROPERTIES Conductor Operating Temperature : 90°C Ambient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 12 (free air)In single-way ductsLaid direct in ground2 cables, single- phase a.c. or d.c.3 or 4 cables,  3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables,  3-phase a.c.3 cables 3-phase a.c. trefoil touching2 cables, singlephase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, singlephase a.c. or d.c.3 or 4 cables, 3-phase a.c.mm2AAAAAAAAAAAVoltage Drop (Per Amp Per Meter)Conductor crosssectional area2 cables d.c.2 cables singlephase a.c.3 or 4 cables three-phase a.c.2 cables singlephase a.c.3 or 4 cables, 3-phase a.c. touchingReference Method 1 & 11 (touching)Reference Method 1, 11 & 12 (in trefoil touching)Reference Method 1 & 11 (Flat touching)In ductsIn groundIn ductsIn ground123456789mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mrxzrxzrxz700.670.680.200.710.590.170.620.60.250.650.800.700.700.61950.490.510.1950.550.440.170.470.460.240.520.650.530.560.461200.360.410.1900.450.350.1650.390.380.240.440.550.430.480.371500.310.330.1850.380.290.1600.330.310.230.390.500.370.430.321850.250.270.1850.330.230.1600.280.260.230.340.450.310.390.272400.1950.210.1800.280.180.1550.240.210.220.300.400.260.350.233000.1550.170.1750.250.1450.1500.210.170.220.280.370.240.320.214000.1150.1450.1700.220.1250.1500.1950.1600.210.270.350.210.300.195000.0930.1250.1700.210.1050.1450.1800.1450.200.250.330.200.280.186300.0730.1050.1650.1950.0920.1450.1700.1350.1950.240.300.190.260.178000.0560.0900.1600.1900.0860.1400.1650.1300.1800.230.280.180.240.1610000.0450.0920.1550.1800.0800.1350.1550.1250.1700.210.260.170.220.15


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Fire Resistant UTP CAT5 Data Cables
Fire Resistant UTP CAT5 Data Cables Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:, compatible with all known conn...
Belden9838
Belden9838 Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9838ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s...
150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Instrumentation Control Cables (Multicore)
150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Instrumentation Control Cables (Multicore) 150/250V Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed Flame Resistant Instrumentation & Control Cables (Multicore)ApplicationThese cab...
3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power Control Cables (Radial Field)
3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power Control Cables (Radial Field) 3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These mediu...
Harmonized Code Industrial Cables H05V2-K H07V2-K
Harmonized Code Industrial Cables H05V2-K H07V2-K Harmonized code Industrial Cables H05V2-K / H07V2-KApplication and DescriptionThese special heat-resistant flexible single-conductor hook-up wires ...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes