automatic trace carbon residue meter FDR-1901
Application range
Electric furnace process carbon residue tester is designed and manufactured according to the requirements specified by the the the National Petrochemical industry standard SH/TO170 "petroleum products Determination of carbon residue (electric furnace method), applicable to the determination of the lubricating oil, heavy liquid fuel or other petroleum products carbon residue.Features
1, the instrument uses the integrated structure design, furnace and controller to form a complete whole new aesthetic.
2, digital temperature controller, main heating and auxiliary heating function, auxiliary heating according to the needs of both automatic control can be manually controlled, easy to use.
3, the highest temperature up to 520 ° C furnace temperature control accuracy up to full temperature control within ± 5 ℃, meet the test requirements.
3 instrument for desktop structure, furnace furnace four hole, four samples can be placed at the same time at the same time test, test high efficiency.
Application range
Automatically trace carbon residue tester is an automatic test equipment for the petroleum products in accordance with the requirements of GB / T 17144, ISO 10370 and ASTM D4530 technology manufacturing.Auto range of trace amounts of carbon residue analyzer the measurement of residual carbon was 0.10% (m / m) ~ 30.0% (m / m).Determination of the results of the equivalent of the carbon residue value exceeds 0.10% (m / m) of petroleum products this tester measurement results and Conradson carbon residue method (GB / T 268).
The automatic trace amounts of carbon residue oximeter also applicable to the determination of the residual carbon values less than 0.10% (m / m), the composition of petroleum products by the distillate.For this product, the first used in GB / T 6536 prepared in 10% (V / V) distillation residue, and then use the auto trace residual carbon analyzer measured.Features
automatic temperature control, automatic constant temperature system
automatically switch traffic, convenient
with one-button operation, the entire test process can be fully automated
· automatic trace carbon residue tester saver test process anomalies and the furnace temperature ultra-high after the instrument will automatically stop and alarm
· automatic trace carbon residue tester using stainless airway emissions, low-carbon, environmentally friendly
· automatic trace carbon residue tester hint system, automatic alarm at the end of the experimentSpecifications
· the combustion chamber operating temperature range: room temperature ~ 500 °C
· the combustion chamber temperature accuracy: 500°C ± 2.0°C; thermostat 15min
· set the time error: <0.1S
· pressure adjustment range: 0 kPa (0 kg/cm2) ~ 392 kPa (4kg/cm2);
· the flow adjustment range: 100 ml / min to 1000 ml / min; automatic switching of 150 ml / min and 600 ml / min;
· the heater power: 1000W
· the temperature control: digital temperature controller