PV module acid corrosion test equipment supplier
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
The Photovoltaic Acid Mist Test Chamber is a specialized device designed to simulate coastal environments with high salt fog concentrations, enabling the evaluation of photovoltaic modules' corrosion resistance. Its core function involves precisely controlling salt mist concentration, temperature, and humidity to accelerate material aging processes, thereby assessing product lifespan under harsh environmental conditions.
Standards
IEC 60068-2-42. IEC 60068-2-43. IEC 60068-2-60
GB/T 10125 Artificial Atmosphere Corrosion Tests - Salt Spray Test
ISO 9227 Corrosion Tests under Artificial Atmospheres - Salt Spray Test
ASTM B117 Laboratory Simulation of Salt Spray Environments (e.g., Marine or Humid Climates)
Features
1.Multi-Gas Synergy: Unlike standard salt spray boxes, this system allows you to introduce $H_2S$, $NO_2$, and $Cl_2$ simultaneously, providing a more realistic "industrial-marine" complex environment.
2.Large-Format Throughput: The internal architecture is optimized to hold six full-sized PV modules, ensuring your testing throughput meets industrial R&D demands.
3.High-Precision Flow Control: Equipped with advanced flowmeters (accuracy $<pm 1%$), giving you total confidence in the repeatability of gas concentration levels.
4.Corrosion-Resistant Build: The chamber interior is constructed from reinforced, high-temperature resistant plastics or specialized alloys to withstand acidic and saline exposure without self-corrosion.
5.Automated Cycle Management: You can program complex sequences of spraying, drying, and humidifying to simulate changing weather patterns over a single test period.
Parameters
| No. | Item | Specifications |
|---|---|---|
| 1 | Temperature Range | +10°C ~ +70°C |
| 2 | Humidity Range | 40% ~ 98% RH (adjustable) |
| 3 | Test Capacity | 6 pieces of 2m × 1.2m photovoltaic modules |
| 4 | Test Gases | Four gases: SiO₂ (Silicon Dioxide), H₂S (Hydrogen Sulfide), NO₂ (Nitrogen Dioxide), Cl₂ (Chlorine).Concentrations can be automatically adjusted according to standard requirements.Flow meter control accuracy: better than ±1% |
Test Procedures
1.Preparation
Sample Preparation: Clean the samples and secure them on the sample rack, ensuring they do not touch each other.
Solution Preparation: Prepare a 5% NaCl solution (pH 6.5-7.2) according to the standard.
2.Power-Up and Parameter Settings
Power Connection: Connect the power supply and turn on the main switch.
Parameter Settings:
Temperature: 35°C ± 2°C (salt spray phase) or 40–60°C (drying phase).
Humidity: 85% RH ±5%.
Test Cycle: Set the number of cycles and duration for spraying, drying, and humidification.
3. Test Operation
Start Test: After confirming parameters are correct, press the “Start” button.
Spray Inspection: Once temperature is reached, the spray system automatically activates. Observe spray uniformity.
Operational Monitoring:
Daily checks of temperature and spray volume.
Periodically replenish salt solution (recommended every 24 hours).
Monitor pressure gauge (0.7-1.5 kgf/cm²).
4. Test Conclusion
Shutdown Procedure: Turn off spray switch, allow temperature to drop below 40°C before disconnecting power.
Sample Removal: Retrieve specimens for corrosion assessment.
Send product request
Other supplier products
| Geomembrane Stress Crack Resistance Tester Manufacturer Direct Sale | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Simultaneous testing of up to 20 specimens to improve efficienc... | |
| Fire Retardant Coatings Tester – Tunnel Method | Whats/App: +86 156 1874 6768 Web: standard-groups.com The fire retardant coating flame propagation tester is suitable for testing the flame propa... | |
| Catheter Flow Meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The catheter flow tester is mainly used to measure and evaluate the flow perf... | |
| High low temperature test chamber for vehicle testing | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications 1. Automotive R&D Testing Cold Start Test: Verifies engine starting perf... | |
| Multi-Segment Thermal Manikin for Heat Transfer Simulation | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Porton-man Thermal Manikin is suitable for a wide range of a... |
Same products
| PP Pickling Tank | Seller: Hebei Annuo Automaiton Technology Co., Ltd. | PP Pickling Tank PP Pickling Tank — Polypropylene Pickling Tanks for Hot Dip Galvanizing... | |
| Galvanizing Tank/Galvanizing Kettle/Zinc Kettle | Seller: Hebei Annuo Automaiton Technology Co., Ltd. | Galvanizing Tank/Galvanizing Kettle/Zinc Kettle Zinc Kettle / Galvanized Kettle for Hot-Dip Ga... | |
| Galvanizing Furnace | Seller: Hebei Annuo Automaiton Technology Co., Ltd. | Galvanizing Furnace Hot Dip Galvanizing Furnace Manufacturer— Engineered for Your Produc... | |
| Flue Gas Heat Economizer waste heat recovery | Seller: Hebei Annuo Automaiton Technology Co., Ltd. | Flue Gas Heat Economizer waste heat recovery Flue Gas Heat Economizer – Waste Heat Recov... | |
| Granite Tanks | Seller: Hebei Annuo Automaiton Technology Co., Ltd. | Granite Tanks Granite Tank — Granite Pickling Tank for Hot Dip Galvanizing The granite ... |