PV module acid corrosion test equipment supplier
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
The Photovoltaic Acid Mist Test Chamber is a specialized device designed to simulate coastal environments with high salt fog concentrations, enabling the evaluation of photovoltaic modules' corrosion resistance. Its core function involves precisely controlling salt mist concentration, temperature, and humidity to accelerate material aging processes, thereby assessing product lifespan under harsh environmental conditions.
Standards
IEC 60068-2-42. IEC 60068-2-43. IEC 60068-2-60
GB/T 10125 Artificial Atmosphere Corrosion Tests - Salt Spray Test
ISO 9227 Corrosion Tests under Artificial Atmospheres - Salt Spray Test
ASTM B117 Laboratory Simulation of Salt Spray Environments (e.g., Marine or Humid Climates)
Features
1.Multi-Gas Synergy: Unlike standard salt spray boxes, this system allows you to introduce $H_2S$, $NO_2$, and $Cl_2$ simultaneously, providing a more realistic "industrial-marine" complex environment.
2.Large-Format Throughput: The internal architecture is optimized to hold six full-sized PV modules, ensuring your testing throughput meets industrial R&D demands.
3.High-Precision Flow Control: Equipped with advanced flowmeters (accuracy $<pm 1%$), giving you total confidence in the repeatability of gas concentration levels.
4.Corrosion-Resistant Build: The chamber interior is constructed from reinforced, high-temperature resistant plastics or specialized alloys to withstand acidic and saline exposure without self-corrosion.
5.Automated Cycle Management: You can program complex sequences of spraying, drying, and humidifying to simulate changing weather patterns over a single test period.
Parameters
| No. | Item | Specifications |
|---|---|---|
| 1 | Temperature Range | +10°C ~ +70°C |
| 2 | Humidity Range | 40% ~ 98% RH (adjustable) |
| 3 | Test Capacity | 6 pieces of 2m × 1.2m photovoltaic modules |
| 4 | Test Gases | Four gases: SiO₂ (Silicon Dioxide), H₂S (Hydrogen Sulfide), NO₂ (Nitrogen Dioxide), Cl₂ (Chlorine).Concentrations can be automatically adjusted according to standard requirements.Flow meter control accuracy: better than ±1% |
Test Procedures
1.Preparation
Sample Preparation: Clean the samples and secure them on the sample rack, ensuring they do not touch each other.
Solution Preparation: Prepare a 5% NaCl solution (pH 6.5-7.2) according to the standard.
2.Power-Up and Parameter Settings
Power Connection: Connect the power supply and turn on the main switch.
Parameter Settings:
Temperature: 35°C ± 2°C (salt spray phase) or 40–60°C (drying phase).
Humidity: 85% RH ±5%.
Test Cycle: Set the number of cycles and duration for spraying, drying, and humidification.
3. Test Operation
Start Test: After confirming parameters are correct, press the “Start” button.
Spray Inspection: Once temperature is reached, the spray system automatically activates. Observe spray uniformity.
Operational Monitoring:
Daily checks of temperature and spray volume.
Periodically replenish salt solution (recommended every 24 hours).
Monitor pressure gauge (0.7-1.5 kgf/cm²).
4. Test Conclusion
Shutdown Procedure: Turn off spray switch, allow temperature to drop below 40°C before disconnecting power.
Sample Removal: Retrieve specimens for corrosion assessment.
Send product request
Other supplier products
| Geomembrane Hydrostatic and Permeability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com As the most cost-effective hydrostatic pressure tester, the Geomembrane Hydrostatic and Per... | |
| Upper Leather Flexing Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Upper Leather Flexing Tester evaluates the flexing endurance and resistance to cracking... | |
| Cantilever Fabric Stiffness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cantilever Fabric Stiffness Tester is a precision instrument designed to evaluate the b... | |
| Blade penetration depth tester machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YY 0174 - 2019: Surgical Blades Features 1. High-Precision Measurement System ... | |
| Laboratory Transient Plane Heat Source Thermal Conductivity Analyzer for Geotechnical Testing | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 22007-2:2008 – Determination of Thermal Conductivity and... |
Same products
| Two-Shot Injection Molds | Seller: WIT MOLD LIMITED | Two-Shot Injection Molds Advantages of two-shot injection molding The benefits of Double Inject... | |
| precision injection molding | Seller: WIT MOLD LIMITED | precision injection molding Precision injection moldingis a method demanding unparalleled accura... | |
| Custom Plastic Molds molding | Seller: WIT MOLD LIMITED | Custom Plastic Molds molding Plastic Molds molding servicesprovide many extremely versatile part... | |
| Thermoset Molding | Seller: WIT MOLD LIMITED | Thermoset Molding Key Aspects of Thermoset Molding Materials: Thermosetting Polymers:These inc... | |
| PE Film Scrap, Rolls, Bale, Regrinds, Lump, LLDPE, HDPE, LDPE | Seller: Plastic scrap, ferrous and non-ferrous metal scraps supplier for recycling | We have PE film scrap, including LLDPE, HDPE, and LDPE, available for ongoing shipment to buyers ... |