Filter Integrity Test System
Get a quote:
Whats/App: +86 185 0176 3615
Web: qinsun-lab.com
Application
(1) Hydrophobic filter integrity testing (water intrusion test).
(2) Hydrophilic liquid filter integrity testing (forward flow and bubble point tests).
(3) Pre-use validation for single-use systems and small-scale process equipment.
(4) Liquid sterilizing filtration systems in pharmaceutical, biotechnology, and life sciences industries.
(5) Gas sterilizing filter integrity verification in the pharmaceutical industry.
(6) Laboratory environments under GMP and 21 CFR Part 11 control.
(7) Verification of various process liquid or gas filters, including laboratory and industrial production processes.
(8) Supports multiple membrane types, including hydrophobic, hydrophilic, and composite membranes.
Testing Standards
ASTM F838 – Membrane bubble point method
ASTM D5199 – Gas and liquid filtration membrane performance testing
ISO 2548 series – Pressure decay and diffusive flow methods
GMP/GDP Filter Validation Guidelines
FDA 21 CFR Part 11 – Data integrity compliance
Product Specifications
| Parameter | Technical Specifications |
|---|---|
| System Size | 1189 × 575 × 856 mm |
| System Weight | Approx. 120 kg (empty water tank) |
| Water Tank Capacity | 18 L (removable, manual/automatic filling) |
| Forward Flow Test Accuracy | ±3% or ±0.05 mL/min (whichever is larger) |
| Water Intrusion Test Accuracy | ±3% or ±0.02 mL/min (whichever is larger) |
| Bubble Point Test Accuracy | ±3% |
| Power Supply | 100–240 VAC, 50/60 Hz, typical power 150 W |
| Compressed Air Pressure | 4500–8000 mbar (58–116 psi) |
| Test Flow Range | FF: 0.1–1000 mL/min; WIT: 0.02–50 mL/min; BP: 400–6500 mbar |
| Test Resolution | FF: 0.1 mL/min ( |
| Touch Screen | 26.4 cm diagonal, 1024 × 768 pixels, backlit, adjustable contrast |
| Protection Level | IP54 (splash-proof) |
| Environmental Conditions | Operating temperature: 5–50℃; Storage temperature: -20–70℃; Relative humidity: 95% RH (non-condensing) |
Send product request
Other supplier products
| comparative tracking index tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Comparative tracking index testeris suitable for th... | |
| Guide pin anchoring force tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Guide Pin Anchoring Force Tester is designed to evaluate the anchoring perform... | |
| Textile Far Infrared Radiation Temperature Rise Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Applications Textile Far Infrared Radiation Temperature Rise Tester is used for v... | |
| Wool Fineness Analyzer - lab instrument | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Wool fiber fineness value is measured by the airflo... | |
| Smoke Density Chamber | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com The main principle is to measure smoke density in a... |
Same products
| Choosing the Right Equipment for Heavy-Duty Cleaning | Seller: Taizhou Feike Mechanical Technology Co., Ltd. | FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve... | |
| ER4043 Silicon Aluminum Welding Wire | Seller: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin... | |
| HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line | Seller: Shandong HUASU Plastic Technology Co.,Ltd. | The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi... | |
| PanEVAP & MVR system | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... |