Applications
Pharmaceutical Stability Testing Laboratory is designed for conducting accelerated humidity and heat testing, long-term stability testing, and constant humidity and heat testing on pharmaceutical intermediates, active pharmaceutical ingredients, finished pharmaceutical products, and medical devices. It also supports cultivation of plant and animal samples and bacterial cultures, as well as low-temperature storage, enabling analysis and evaluation of product behavior. This facility serves dedicated research in pharmaceuticals, medicine, biotechnology, food processing, electronics, and all life science-related industries.
Standards
WHO Principles Require:
Long-term stability testing conditions at 25°C/60% RH humidity.
The 40°C/75% RH humidity standard for 6-month accelerated testing is primarily applied in the pharmaceutical industry's stability testing systems, simulating environmental climate conditions including temperature, humidity, and light exposure.
Parameters
| Item | Specification |
|---|---|
| Test Area Dimension | Specific dimensions to be designated by the customer based on usage conditions! |
| External Dimension | Subject to the quotation plan |
| Operating Temperature Range | SBY: 0°C ~ +60°C |
| Relative Humidity Range | 30% ~ 95% RH |
| Temperature Deviation | ≤±2°C (≤1°C for incubation chambers) |
| Humidity Deviation | ±5% RH |
| Temperature Fluctuation | ≤±0.5°C |
| Heating Time | ≤30 min |
| Cooling Time | 30 min ~ 180 min (varies by model) |
| Material | Exterior: A3 color steel plate + spray coating; Interior: SUS#304 stainless steel; Insulation layer: PU foam |
| Temperature & Humidity Control System | Imported fully-hermetic or semi-hermetic compressor from Europe, America, Japan, or Korea; Refrigerant: R134a; Axial flow fan with side/top air outlet; High-performance heater; Steam humidification; ADP critical point condensation dehumidification; Air-cooled or water-cooled options |
| Controller | Adopt Yonghe's own brand or Korean TH500/TH300 touch screen controller; Display precision: Temperature 0.1°C, Humidity 0.1% RH; Operation modes: Program mode, fixed value mode; Control method: Microcomputer PID with integral operation; Input signal: PT100 platinum resistance |
| Observation Window | Multi-layer hollow anti-fog explosion-proof glass |
| Safety Devices | Over-temperature protection, leakage protection, water shortage protection, humidification system protection, compressor over-pressure/overload/over-current protection, fan overload protection, phase sequence protection |
| Power Supply | AC380V (1±10%) V, 50±0.5 Hz, 3-phase 4-wire + protective earth |
| Optional Accessories | Temperature & humidity recorder (capable of simultaneous recording of temperature/humidity signals and multiple test points), large observation window, test hole, SMS alarm, high/low temperature deviation alarm, dual-compressor system, etc. |
| Extendable Products | Constant temperature incubation chamber, constant temperature & humidity test chamber, high-low temperature test chamber, constant temperature room, aging test chamber, burnout test chamber, etc. |
| Special Notes | Customizable dimensions available to meet customer requirements |
Accessories
1.Data Recording: Multi-channel temperature and humidity recorders (paper or paperless) for regulatory auditing.
2.Access Ports: Standard 50mm diameter test holes with silicone plugs for external cable routing.
3.Visual Monitoring: Multi-layered hollow explosion-proof glass observation windows with anti-frost coatings.
4.Systems: SMS remote alarm modules and local sound/light indicators for deviation alerts.
5.Redundancy: Dual-compressor backup systems to ensure zero downtime during critical long-term studies.
Send product request
Other supplier products
| Mechanical load testing machine for photovoltaic modules | Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval IEC 61646: Thin-Film Terrestrial Photovo... | |
| Surface Performance Tester STD-FB4 - A | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by artisans and professionals when judging a fabric&rsquo... | |
| Torsional Fatigue Tester | Standard YY/T 0857-2011 (China): Specifies torsional fatigue testing protocols for spinal pedicle screw-rod systems, including load ratios, freque... | |
| Particle Strength Tester | Standard ASTM D4179: Standard Test Method for Single-Pellet Pressure Resistance of Catalysts and Catalyst Carriers ASTM D6175: Standard Test Me... | |
| Fiber Blend Ratio meter | Product Introduction: It is used to measure the resistance value with a certain density under a certain geometry, and then converts it into the sp... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |