Laboratory PVT coolant pulse testing equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The PVT Coolant Pulse Test Machine complies with a broad range of international automotive standards, including:
VW 78007 / TL 82048 / TL 81165 / TL 874 (4.4) – Volkswagen Group specifications for cooling system and interior material performance
TL 82002 / TL 52682 / TL 886 / TL 889 / TL 82086 – Volkswagen Group specifications for system component material performance and durability
PV 1712 (Ag 99-03) / GMW3155 – Fiat / General Motors engineering specifications for materials and component performance
PTL14052-A1203 / PTL14100-A0911 – Internal technical standards for component functionality and reliability
BMW LH 10356681 (10.5) / LH 10757369 (6.) / QV 17004 – BMW Group engineering specifications for material and component functionality and durability
BMW LH 7823444.6 / LH 10591317 / LH 10274837 – BMW Group engineering specifications for system component performance and functional validation
DIN 73411-2 [39] / Daimler M139 (2) / M177 (2) – Daimler engineering specifications / German industrial standards for component material and functional testing
Parameters
| Parameter | Details |
|---|---|
| Machine Dimensions | 4350 mm × 2520 mm × 2150 mm (W × H × D) |
| Test Chamber Internal Dimensions | 1800 × 1000 × 1000 mm (W × H × D) |
| Rated Power | 60 kW |
| Test Medium | Glycol / Water |
| Pressure Range | 0 … 5 bar |
| Medium Flow Control | Up to approx. 100 l/min |
| Linear Motion | ±25 mm at 1 Hz ±12 mm at 5 Hz ±6 mm at 10 Hz ±2 mm at 20 Hz |
| Test Medium Temperature Range | -40°C … +150°C |
| Environment Temperature Control Range | -40°C … +150°C |
| Test Channels | 8 |
Features
Combines linear and eccentric motion mechanisms for pressure pulse testing.
Operates in a pressure range of 0.1 … 5 bar.
Heats the test chamber by monitoring maximum surface temperature limits.
Automatic leak detection and leak testing with shutdown of failed samples.
Integrated recirculation pump prevents coolant leakage.
Windows / LabView-based control unit for data acquisition and monitoring.
Accessories
Test hoses and fittings
Data acquisition sensors
Leak detection probes
Temperature control modules
Linear and eccentric motion actuators
Test Procedures
Install the component to be tested in the test chamber.
Connect the test medium (glycol/water) and set the desired flow rate.
Configure test parameters including pressure range, linear/eccentric motion frequency, and temperature range.
Start the test via the Windows/LabView control unit.
Monitor real-time data for pressure, temperature, and leak detection.
The machine will automatically stop and alert you if a sample fails.
Record and export test results for analysis.
Maintenance Information
Regularly check and clean the recirculation pump and medium lines to prevent blockages.
Inspect motion actuators for wear and lubricate as recommended.
Calibrate pressure and temperature sensors periodically to ensure accurate testing.
Clean the test chamber and remove any residue from previous tests.
Update the control software and verify data acquisition integrity.
Send product request
Other supplier products
| Syringe barrel pressure integrity tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is suitable for evaluating a wide range of medical devices with Lu... | |
| UV Aging Test Chamber | The UV aging test chamber is suitable for all kinds of geo-synthetics, such as light resistance, weather resistance and light ageing The exposure ... | |
| Safety Helmets Impact and Penetration Resistance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 2811-2019(China’s national standard for helmet safety and impact res... | |
| Expansion Tank Static Pressure Test Machine,High pressure expansion tank static tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Expansion Tank Static Pressure Test Machine is a specialized system designed to evaluat... | |
| Safety Helmets Against Molten Metal Splashing Tester | Standard GB/T 2812-XXXX: Safety Helmets – Test Methods for Molten Metal Resistance (Draft Standard) GB 2811-2019: Head Protection – G... |
Same products
| ISO 29463 HEPA/ULPA filter performance testing System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| Mobile Floor Scrubber Aging Life Tester IEC 60312 | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheMobile Floor Scrubber Aging L... | |
| ISO 12103 Cleanable Filter Media Test System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Robotic Vacuum Cleaners Edge-Following Tester | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheEdge-Following Test Equipment... |