Bend catheter flexibility equipment

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

ISO 10555 -Intravascular catheters- Sterile and single-use catheters

ISO 11o70- Catheter introducers, dilators, and guidewires

ASTM F2394-Guidewire mechanical property evaluation

ASTM F2908- Stiffness and flexibility of guidewires

ISO 178:2oo1 -Flexural properties of plastics (applicable to catheter materials)

Features

7-inch touchscreen interface with programmable test parameters and intuitive controls

Real-time force vs. displacement data acquisition with automated reporting

Dual-system control for independent force and displacement parameter setting

High-precision ball screw drive and guide mechanism for smooth operation

O.5% FS force sensor accuracy with resolution up to O.01 N

Supports catheter diameters up to 3.3 mm (customization available)

Advanced displacement control with O.1 mm accuracy

Pneumatic clamping system designed for fast, secure catheter mounting

Stores up to 1oo,ooo test records, supports audit trails and data export

Includes Rs232 interface and micro printer for traceable output

Technical Parameters

ParameterSpecification
Testing Range (Force Range) Usually 0 - 10 kilograms or more, depending on the tester's model and specifications
Testing Stroke Varies in vertical & horizontal directions; e.g., vertical stroke: 0 - 300mm, horizontal stroke: 0 - 700mm
Testing Speed - Press-down Speed: Adjustable within 0 - 300mm/min- Wire-drawing Speed (for applicable testers): 0 - 500mm/min or faster
Catheter Clamping Method Usually adopts pneumatic or mechanical clamping, ensuring the stability and accuracy of the catheter during testing
Control System Adopts PLC control system (high precision & stability); operation interface may be equipped with a color touch screen for convenient setting and operation

Accessoriess

Main unit, computer, horizontal traction module, pneumatic gripper, 7-inch color touch screen

Test Procedures

1. Insert the intervention catheter into the test pulley system and secure it, ensuring the correct spacing.

2. Adjust the vertical spacing of the test pulleys to maintain a constant test distance.

3. Connect one end of the catheter to the traction head, ensuring the traction head guides the catheter at a constant speed.

4. Monitor the force value change curve during the test using computer software.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

ISO 8536 infusion set positive pressure leakage tester
ISO 8536 infusion set positive pressure leakage tester Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Infusion Set Positive Pressure Leakage Tester is a dedicated testing inst...
IEC61215 Wet Leakage Current Testing Machine
IEC61215 Wet Leakage Current Testing Machine Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Wet Leakage Current Test System is designed for high-precision evaluation...
Affordable Wear Track Profilometer tester
Affordable Wear Track Profilometer tester Whats/App: +86 156 1874 6768 Web: standard-groups.com A wear profiler is a device used to measure the characteristics of worn surfaces, providing...
Carpet Pilling and Fuzzing Tester
Carpet Pilling and Fuzzing Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Instrument Description This instrument is used to simulate the pilling and fuzzing phenome...
Gas Hazardous Characteristics Tester
Gas Hazardous Characteristics Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction This tester is used to test the flammable concentration range of gase...
All supplier products

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...