Aluminum ointment tube compression strength tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The design and manufacture of the ductility tester for aluminum tubes usually comply with a series of national and international standards to ensure the accuracy and reliability of test results. Among them, common standards include YBB00162002 - 2015 Aluminum Pharmaceutical Soft Tubes, etc. These standards specify in detail the test methods for the ductility of aluminum tubes, specimen preparation, test conditions, etc., providing a unified standard for the use of the tester.

Features

Designed strictly according to national or industry standards, it meets standard testing requirements, ensuring compliant test results and accommodating all hose specifications.

Utilizing a high-precision measurement system, it accurately reads the gate's scale markings, thus quantifying the aluminum tube's toughness.

Made of 304 stainless steel with electroplating, it boasts a beautiful appearance and high material strength.

Technical Parameters

Technical ParameterSpecification
Measurement Range Usually applicable to aluminum soft tubes with a diameter between 10 and 45mm (some devices cover 8-45mm) and a certain tube length; covers most common aluminum tube specifications for wide applicability.
Gate Plate Weight Precisely controlled within 70g±1g (a key pressure-applying component, ensuring testing consistency and accuracy).
Testing Accuracy Equipped with a high-precision measurement system (e.g., current measurement accuracy reaches ±0.1mA) to quantify aluminum tube deformation under external forces (specific accuracy varies by device).
Automation Level Adopts automatic and intelligent technologies; features one-click operation, automatic timing, and data recording to reduce operator burden and improve test accuracy/traceability.
Appearance Dimensions and Weight Usually compact and portable (varies by model/brand), enabling use in different production sites and laboratories for flexible, convenient testing.
Working Environment Requires a specific environment: working temperature 23℃±2℃, relative humidity ≤80% (no condensation); ensures equipment stability and test result accuracy.

Accessoriess

Standard configuration: Main unit

Test Procedures

Select a suitable stepped support.

Place the sample onto the mandrel, with the tail end of the tube fitted onto the first-level step corresponding to the aluminum tube's specifications. The mandrel should extend from the nozzle. The aluminum tube should remain perpendicular to the base throughout the test. Place the top pressure plate over the extended mandrel and gently rest it on the top of the nozzle. Apply uniform pressure to the pressure plate and quickly press the aluminum tube downwards. The aluminum tube should exhibit a uniformly folded "accordion" shape. Remove the pressed aluminum tube from the mandrel and stretch it as close to its original length as possible. Cut it longitudinally and observe the surfaces of the inner and outer coatings. There should be no cracks or peeling in the inner and outer coatings.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Cloth Material Comfort Evaluation Device
Cloth Material Comfort Evaluation Device Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The instrument is widely used in: Textile R&D: Quantifying fabric hand fe...
Torsional Fatigue Tester
Torsional Fatigue Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0857-2011 (China): Specifies torsional fatigue testing protocols for spinal ...
UV Lamp Aging Test Tester
UV Lamp Aging Test Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM D4329 Standard Practice for Fluorescent UV Exposure of Plastics ASTM D4587...
Thermal Cycling Damp Heat and Freeze Test Chamber
Thermal Cycling Damp Heat and Freeze Test Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This chamber is widely used in photovoltaic and related renewable energy field...
Diaper Anti-Side Leakage Performance Tester
Diaper Anti-Side Leakage Performance Tester The Diaper Anti-Side Leakage Performance Tester is designed to accurately measure the liquid loss of nonwoven materials and evaluate the anti-side ...
All supplier products

Same products

Surface adhesion testing equipment factory price
Surface adhesion testing equipment factory price Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards JIS L 1066 (Testing Methods fo...
Continuous load scratch resistance tester manufacturer
Continuous load scratch resistance tester manufacturer Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO DIS 12137-2 (Plastics &mda...
High precision continuous load surface tester
High precision continuous load surface tester Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...
Multi-function surface performance test system
Multi-function surface performance test system Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...
Laboratory tribology research equipment
Laboratory tribology research equipment Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...