Environmental Stress Cracking Resistance Tester
This instrument is a testing device recommended according to standard requirements. It is a specialized device designed specifically for environmental stress cracking tests of polyethylene plastics. This testing device retains the technical requirements of the original prototype while incorporating structural innovations. It features a sophisticated design and advanced technology.
Applications
1. Plastic and Rubber Material Research and Development: Evaluating the stress crack resistance of new plastic and rubber materials under different environmental conditions, and optimizing material formulations and structures.
2. Product Quality Testing: Conducting quality testing on raw materials, semi-finished products, and finished products to ensure that products meet relevant standards and customer requirements.
3. Component Reliability Testing: Testing components (such as casings and brackets) in electronic and electrical products to identify potential problems in advance and optimize design and manufacturing processes.
4. Packaging Material Evaluation: Evaluating the performance changes of packaging materials under different temperatures, humidity levels, and storage times, providing a basis for selecting suitable packaging materials.
Standards
ASTM D1693: Exclusively designed for bending beam and constant load tests on polyethylene and other thermoplastics.
ISO 22088-3: Configurable for notched specimen testing in aggressive media.
Features
Modular Bath System:
46-position carousel with quick-release glass vessels (250mL capacity).
Dual-circuit heating for rapid temperature equilibration.
Stress Loading System:
Manual or motorized bending fixtures with 0–50N load range.
Laser-aligned specimen grips for consistent strain distribution.
Chemical Management:
Integrated solvent level sensors with low-volume alerts.
Vented enclosure for fume extraction (compatible with external HVA systems).
Data Integrity:
100Hz sampling rate captures crack initiation events.
Wireless data export via Wi-Fi/Bluetooth to LIMS platforms.
Safety Suite:
Leak-proof magnetic drive stirrers.
Emergency solvent dump system with CO₂ fire suppression.
Technical Parameters
| Specification | Details |
|---|---|
| Temperature Range | -10°C to 100°C (water/glycol bath) |
| Temperature Accuracy | ±0.2°C (±0.1°C with calibration kit) |
| Sample Capacity | 460 specimens (46 vessels × 10 samples) |
| Stress Load Range | 0–50N (0.1N resolution) |
| Power Supply | 220V/50Hz (110V/60Hz available) |
| Bath Volume | 60L (expandable to 120L) |
| Dimensions (W×D×H) | 1.200mm × 800mm × 1.850mm |
| Weight | 280 kg (net) |
Accessoriess
Sample Preparation Kit:
ASTM D1693-compliant milling cutters and polishing films.
Prefabricated specimen jigs for 2.75mm bending beams.
Solvent Management:
Explosion-proof storage cabinet for flammable liquids.
Recirculating chiller for sub-ambient testing (-10°C).
Advanced Analytics:
CrackVision™ Software: AI-assisted image analysis for crack length measurement.
LabCloud Pro: Remote monitoring for 100+ concurrent users.
Calibration Bundle:
NIST-traceable temperature/force calibration kit with certificate.
Extended Warranty:
5-year comprehensive coverage for bath and controls.
Test Procedures
1. Set appropriate test parameters
Based on specific requirements, determine appropriate test parameters such as temperature, humidity, stress, or strain to ensure the accuracy and repeatability of the test results.
2. Select suitable test specimens
Select suitable specimen shapes and sizes based on the material characteristics, and ensure that the specimen preparation process meets standard requirements.
3. Data analysis and interpretation
Perform systematic analysis and interpretation of the test results, including indicators such as cracking time, cracking distance, and crack propagation rate, to provide a scientific basis for subsequent applications and decision-making.
4. Safe operation
During operation, pay attention to safety precautions, ensuring that the test platform is stable and avoiding excessive stress or strain that could cause damage to equipment or personnel.
Send product request
Other supplier products
| Rapid screening Calorimeter | The rapid - screening calorimeter is a professional calorimetric instrument for the quick assessment of reaction thermal hazards. It supports multi... | |
| Socks wear tester | Product Introduction: Socks wear tester is a special equipment, mainly used to test the wear resistance of socks material. It evaluates the comfor... | |
| Tibial Tray Fatigue Testing Machine | Standard YY/T 0810 (China): Specifies fatigue testing protocols for tibial trays in total knee arthroplasty, focusing on support and protection of... | |
| Finished shoe bending tester丨Finished shoe bending test mechine | Product Introduction: Finished shoes bending testing machine Finished shoes bending testing machine Test shoes, casual shoes, work shoes and other... | |
| Rubber Low Temperature Brittleness Tester | The Rubber Low Temperature Brittleness Tester determines the temperature at which rubber and plastic samples become brittle under impact conditions... |
Same products
| Gas Oxidizing Property Tester | Seller: Standard International Group (HK) Limited | Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylind... | |
| Battery Powder Compaction Density Measurement System | Seller: Standard International Group (HK) Limited | The Battery Powder Compaction Density Measurement System is a precision testing system designed... | |
| Battery Powder resistance tester | Seller: Standard International Group (HK) Limited | The Powder Resistivity Meter is a precision testing system designed to measure electrical resisti... | |
| KES-SESRU surface roughness/friction tester | Seller: Standard International Group (HK) Limited | TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by artisans ... | |
| Air Permeability Tester STD- F8 | Seller: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... |