Automated Flow Reaction Calorimeter
Whats/App: +86 156 1874 6768
Web: standard-groups.com
This instrument is a professional testing instrument that simulates the specific process of chemical reactions on a liter scale, and measures and controls important process variables. It can simulate the real situation of batch or semi-batch reactions in a factory under laboratory conditions.
Applications
This instrument simulates real-world intermittent or semi-intermittent reactions in a factory, measuring the exothermic heat flow of samples within the reactor in real time. It obtains information on the total exothermic heat, specific exothermic heat, real-time conversion rate, and material accumulation, automatically calibrating the specific heat capacity and heat transfer coefficient of the material system. It then calculates the adiabatic temperature rise of the target reaction and the maximum temperature the system can reach after runaway, thereby assessing the hazard level of the reaction process and providing a basis for process optimization and scale-up. It is widely used in reaction process design, process optimization and scale-up, process safety assessment, and scientific research on reaction thermodynamics in fields such as fine chemicals, pharmaceuticals, agricultural fertilizers, and third-party safety assessment.
Standards
(1)GB 51283-2020: Fire Protection Standard for Engineering Design of Fine Chemical Enterprises
(2)GB/T 22232-2008: Determination of Thermal Stability of Chemical Substances - Differential Scanning Calorimetry
(3)GB/T 17802-2011: Thermal Analysis Test Method for Kinetic Constants of Thermally Unstable Substances
(4)SN/T 3078.1-2012: Guidelines for the Evaluation of Thermal Stability of Chemicals - Part 1: Accelerated Calorimetry
Features
(1) It offers three calorimetry methods: heat - flow, power - compensation, and reflux, allowing users to choose according to their needs.
(2) It supports multiple operation modes such as isothermal, constant - temperature, and scanning.
(3)Optional glass normal - pressure reaction vessels, glass medium - pressure reaction vessels, and metal high - pressure reaction vessels are available.
(4) It has an external database, and one system supports the interchange of multiple sets of reaction vessels.
(5) With high - power heating and cooling units, it features fast temperature - control response and high - precision exothermic measurement.
(6) Automatic feeding control can be achieved by mass or volume measurement.
(7)It can accurately measure and obtain process - safety - related data such as reaction heat - flow, reaction enthalpy, conversion rate, specific heat capacity of samples, adiabatic temperature rise, and the maximum temperature that an out - of - control system can reach.
(8)The Chinese - language software platform enables flexible programming of experimental procedures, real - time monitoring of key reaction - process data, and online modification of experimental procedures and parameters.
(9) It can display the temperature inside the vessel, the temperature of the jacket, the mass of the added materials, and other test status information in real - time.
(10)The safety thresholds for key parameters and states can be set. In case of reaction out - of - control, it can be quickly cooled with one click, and it will issue alarms and automatically stop in case of abnormal states, effectively ensuring safety.
(11)It can automatically generate and save charts and data, and export experimental analysis reports.
Technical Parameters
|
Calorimetry Method |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Temperature Control |
|
|
Kettle Temperature Range |
(-25 to 200)°C |
|
Oil Bath Temperature Range |
(-45 to 250)°C |
|
Control Method |
Isothermal, Constant Temperature, Scanning |
|
Temperature Resolution |
1.0mK |
|
Temperature Control Precision |
±0.1K |
|
Silicone Oil Circulation Speed |
(35 to 76)L/min |
|
Control |
|
|
Driver Voltage Range |
(0 to 50)VDC |
|
Driver Maximum Current |
3.0A |
|
Heater Maximum Power |
120W |
|
Atmospheric Pressure Glass Kettle (Option) |
1000mL, other volumes available |
|
Reactor Volume |
Atmospheric Pressure |
|
Working Pressure |
Glass |
|
Reactor Material |
Medium-Pressure Glass Kettle (Option) |
|
Medium-Pressure Glass Kettle (Option) |
|
|
Reactor Volume |
0.6MPa or 1.2MPa |
|
Working Pressure |
Glass |
|
Kettle Material |
316L Stainless Steel or Hastelloy |
|
Kettle Lid Material |
1000mL, other volumes customizable |
|
High-Pressure Metal Reactor ( (Optional) |
10MPa |
|
Reactor volume |
316L Stainless Steel or Hastelloy |
|
Working pressure |
Stirrer |
|
Reactor material |
2000r/min, 3000r/min optional |
|
Stirrer |
|
|
Maximum speed |
Anchor or Paddle |
|
Maximum torque |
PTFE, 316L, or Hastelloy |
|
Stirrer paddle form |
Sampling system |
|
Stirrer paddle material |
Range 3100g, Accuracy 0.01g |
|
Sampling system |
|
|
Precision balance |
Medium-pressure pump: electromagnetic diaphragm pump, the maximum flow rate of 2L / h; high-pressure pump: precision piston pump, the maximum flow rate of 2.4L / h |
|
Sampling channel |
3*400V/50Hz(±10%)/20A |
|
Sampling pump |
7000VA |
|
Other parameters |
1200mm*600mm*1850mm |
|
Power supply |
600mm*700mm*1300mm |
|
Power |
210kg |
|
Test area size |
300kg |
|
Oil bath size |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Oil bath weight |
Temperature Control |
|
Total machine weight |
(-25 to 200)°C |
Send product request
Other supplier products
| Custom wide-range load friction and wear testing equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This testing machine is suitable for a wide range of friction and wear evaluat... | |
| Wet Abrasion Scrub Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Wet Abrasion Scrub Tester is designed to evaluate the resistance of painted, coated, or... | |
| Particle Strength Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Particle Strength Tester is a high-precision instrument designed to measure the mechani... | |
| Pendulum Impact Tester manufacturer direct factory price China supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM D 256-2010、ASTM D6110-2004、 ISO 180:2000、ISO 179-1:2010、ISO ... | |
| Finger Tactile Tester Sensor | Whats/App: +86 156 1874 6768 Web: standard-groups.com Finger Tactile Sensor is a "sensor that measures natural finger operations"with a built-in ... |