Contact Lens Luminous Transmittance Analyzer
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Contact Lens Luminous Transmittance Analyzer is a precision instrument designed to measure the spectral transmittance of soft and hard contact lenses, including hydrogel, silicone hydrogel, artificial cornea, RGP, and Ortho-K lenses. The instrument integrates a built-in integrating sphere to ensure highly accurate measurements that comply with international standards. It features a specially designed lens clamp that prevents deformation, enabling reliable and repeatable results. This analyzer is ideal for manufacturers, laboratories, and research institutions focusing on optical performance evaluation and quality control of contact lenses.
Application
(1) Measurement of spectral transmittance for soft contact lenses (hydrogel/silicone hydrogel/artificial cornea).
(2) Measurement of spectral transmittance for hard contact lenses (RGP, Ortho-K).
(3) Quality control in contact lens manufacturing.
(4) Research and development of new lens materials with specific optical properties.
(5) Verification of compliance with national and international standards for ophthalmic optics.
(6) Optical characterization for product certification and regulatory submission.
Standards
(1) GB/T 11417.5 – Ophthalmic optics – Contact lenses – Spectral transmittance test method.
(2) ISO 18369 – Ophthalmic optics – Contact lenses – Requirements and test methods.
(3) ANSI Z80.20 – American National Standard for Contact Lens Optical Properties.
(4) ISO 8980-4 – Ophthalmic optics – Lenses for correction of vision – Part 4: Transmittance specifications.
(5) IEC 61010 – Safety requirements for laboratory and measuring equipment.
Features
(1) Built-in integrating sphere ensures uniform illumination and accurate lens transmittance measurement.
(2) Specially designed lens clamp prevents deformation for both soft and hard lenses.
(3) Wide spectral range (280–780 nm) for comprehensive optical evaluation.
(4) Adjustable wavelength interval (1–10 nm) for high-resolution measurement.
(5) High measurement accuracy with transmittance repeatability <1% and absolute error <1%.
(6) Supports measurement in air or solution (pure water or standard saline).
(7) User-friendly software interface compatible with Windows 7/8/10/11.
(8) Data output via USB for easy integration with laboratory information systems.
Technical Parameters
| Parameter | Specification |
|---|---|
| Measurement Medium | Air, solution (pure water or standard salt solution) |
| Measuring Aperture | 6 mm |
| Maximum Lens Diameter | 18 mm |
| Wavelength Range | 280–780 nm |
| Wavelength Interval | 1–10 nm adjustable (default 5 nm) |
| Transmittance Repeatability | <1.0% |
| Absolute Transmittance Error | <1.0% |
| Instrument Size (W×D×H) | 600 × 440 × 190 mm |
| Weight | ~26.5 kg |
| Power Supply | AC 100–220 V, 50 Hz, 150 W |
| Operating System | Windows 7/8/10/11 |
| Data Interface | USB |
Send product request
Other supplier products
| Programmable Ozone Test Chamber | Whats/App: +86 156 1874 6768Web: standard-groups.com study the effects of ozone on rubber, and then identify and evaluate the method to resist ozo... | |
| Automobile Headrest Strength Tester,Automotive seat headrest impact strength testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automobile Headrest Strength Tester is designed to evaluate the ultimate strength and d... | |
| Surface Scratch Resistance Testing Machine Manufacturer & Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Surface Scratch Resistance Testing Machine is a PLC-controlled instrument... | |
| EN 60312 Vacuum Cleaner Filtration Test Machine | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com For emission tests the suction air is prepared with a dust concentration of 5... | |
| Goggle Puncture Resistance Evaluation Apparatus | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable standards: GB 811-2010 ECE R22.05 EN1077 Purpose It is to make a certain we... |
Same products
| PanEVAP & MVR system | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... | |
| PanPHE gasketed plate heat exchangers | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ... |