Oxidation Induction Phase Analysis Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Differential Scanning Calorimeter DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, Enthalpy, oxidation induction time (OIT).
Application
It is used to determine the time of automatic catalytic oxidation of the sample at room temperature hydrogen, and to evaluate the thermal stability of the sample. It is suitable for plastics and rubber materials.
Standard
GB/T17391-1998:Polyolefin pipe systems for the conveyance of fluids under pressure - Test methods for the resistance to internal pressure
ISO/TR10837:1991:Technical Report on the use of plastics pipes and fittings for the conveyance of drinking water - Guidelines for the selection of materials and components
ASTM D3895-1998:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)
ASTM E 967:Standard Practice for Temperature Calibration of Thermocouples and Thermocouple Materials by Comparison Techniques
ASTM E 968:Standard Practice for Thermal Cycling of Electronic Components and Materials for Temperature Stress Screening
ASTM E 793:Standard Test Method for Measuring Surface Discontinuities on Metal Surfaces by Electromagnetic (Eddy-Current) Method
ASTM D 3895:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)
ASTM D 3417:Standard Test Method for Thermogravimetric Analysis (TGA) of Polymers
ASTM D 3418:Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC)
ISO 11357-6:Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)
EN 728:Thermal insulating products for building applications - Determination of water vapour transmission properties
Features
The instrument has stable performance, high measurement accuracy and good repeatability;
Designed for measuring oxidation induction period in plastics and rubber industry:
* Integrated design, temperature control and furnace device are integrated, reducing signal loss and interference, beautiful and exquisite appearance;
The furnace body adopts the upper cover structure, no need to lift, convenient loading sample;
* High-resolution data acquisition system, real-time data acquisition;
Intelligent adaptive single-chip microprocessor temperature control system, temperature control speed, high precision:
* Perfect two-way air valve control system, using the original imported flow valve from the United States, can realize the automatic switching of ammonia to oxygen during the measurement process;
Professional oxidation induction period test software with automatic temperature correction and automatic test program to automatically calibrate temperature, test oxidation induction time and plot curves:
Simple operation method, to achieve one-click testing, test results can be saved and printed:
Computer real-time display instrument status, test data and curves, easy to view.
Parameters
| Description | Details |
|---|---|
| Maximum tensile stress | 20MPa |
| Number of stations | 30 (can be customized) |
| Water bath temperature range | RT - 90°C |
| Temperature control accuracy | ±1°C |
| Switch sensitivity | 200g |
| Timing accuracy | 1s |
| Sample thickness | 0.75 - 3mm |
| Notch depth | 20% of the nominal thickness of the sample (6 - specified as an example value, if relevant) |
| Power supply | AC 380V 50HZ |
| Overall dimensions | 1420x640x1900mm |
| Weight | 380kg |
Send product request
Other supplier products
| Suture Needle Penetration and Bending Strength Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Suture Needle Puncture and Bending Strength Tester has broad application prospects and ... | |
| Sponge foam collapsible hardness tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com This machine is used to measure the indentation hardness of porous elastic materials. The p... | |
| Civil Engineering Geotextile Pore Size Classification Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The equivalent pore diameter of geotextile and its related produ... | |
| Hydraulic fluid precision filtration device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Filtration of hydraulic lubrication system during refueling. ● Bypass filtra... | |
| 5 position seatbelt abrasion tester supplier | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ASTM D6770 – Webbing abrasion resistance test (2) FED STD 191 –... |
Same products
| Laser Chuck | Seller: Drake precision technology (changzhou) Co.,Ltd. | Laser Chuck Introduce foreign advanced technology and management concept, High precision pro... | |
| Power Pallet Jack For Sale | Seller: Jinan Hulk Machinery Co., Ltd | Power Pallet Jack For Sale Electric Pallet Truck For Sale As a supplier of power pallet jac... | |
| Multi Directional Forklift For Sale | Seller: Jinan Hulk Machinery Co., Ltd | Multi Directional Forklift For Sale Multi Directional Forklift For Sale As a supplier of mu... | |
| Narrow Aisle Forklift For Sale | Seller: Jinan Hulk Machinery Co., Ltd | Narrow Aisle Forklift For Sale Narrow Aisle Forklift For Sale As a supplier of , we provide... | |
| Electric Order Picker Supplier | Seller: Jinan Hulk Machinery Co., Ltd | Electric Order Picker Supplier Electric Order Picker Supplier As an supplier, we offer a co... |