Accelerated oxidation tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Differential Scanning Calorimeter DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, Enthalpy, oxidation induction time (OIT).
Application
It is used to determine the time of automatic catalytic oxidation of the sample at room temperature hydrogen, and to evaluate the thermal stability of the sample. It is suitable for plastics and rubber materials.
Standard
GB/T17391-1998:Polyolefin pipe systems for the conveyance of fluids under pressure - Test methods for the resistance to internal pressure
ISO/TR10837:1991:Technical Report on the use of plastics pipes and fittings for the conveyance of drinking water - Guidelines for the selection of materials and components
ASTM D3895-1998:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)
ASTM E 967:Standard Practice for Temperature Calibration of Thermocouples and Thermocouple Materials by Comparison Techniques
ASTM E 968:Standard Practice for Thermal Cycling of Electronic Components and Materials for Temperature Stress Screening
ASTM E 793:Standard Test Method for Measuring Surface Discontinuities on Metal Surfaces by Electromagnetic (Eddy-Current) Method
ASTM D 3895:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)
ASTM D 3417:Standard Test Method for Thermogravimetric Analysis (TGA) of Polymers
ASTM D 3418:Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC)
ISO 11357-6:Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)
EN 728:Thermal insulating products for building applications - Determination of water vapour transmission properties
Features
The instrument has stable performance, high measurement accuracy and good repeatability;
Designed for measuring oxidation induction period in plastics and rubber industry:
* Integrated design, temperature control and furnace device are integrated, reducing signal loss and interference, beautiful and exquisite appearance;
The furnace body adopts the upper cover structure, no need to lift, convenient loading sample;
* High-resolution data acquisition system, real-time data acquisition;
Intelligent adaptive single-chip microprocessor temperature control system, temperature control speed, high precision:
* Perfect two-way air valve control system, using the original imported flow valve from the United States, can realize the automatic switching of ammonia to oxygen during the measurement process;
Professional oxidation induction period test software with automatic temperature correction and automatic test program to automatically calibrate temperature, test oxidation induction time and plot curves:
Simple operation method, to achieve one-click testing, test results can be saved and printed:
Computer real-time display instrument status, test data and curves, easy to view.
Parameters
| Description | Details |
|---|---|
| Maximum tensile stress | 20MPa |
| Number of stations | 30 (can be customized) |
| Water bath temperature range | RT - 90°C |
| Temperature control accuracy | ±1°C |
| Switch sensitivity | 200g |
| Timing accuracy | 1s |
| Sample thickness | 0.75 - 3mm |
| Notch depth | 20% of the nominal thickness of the sample (6 - specified as an example value, if relevant) |
| Power supply | AC 380V 50HZ |
| Overall dimensions | 1420x640x1900mm |
| Weight | 380kg |
Send product request
Other supplier products
| ASTM & ISO Paint Surface Scratch Resistance Tester Manufacturer & Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Paint Surface Scratch Resistance Tester is a precision instrument designe... | |
| Carpet Peel & Tuft Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Details For tufted carpets or traditional carpets, an important parameter is the r... | |
| Engine Blow-By Gas Measurement Test Rig | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications determination of oil content in blow-by on the engine test stand evaluation ... | |
| Rolling load tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com A common requirement for different types of indoor sports surfaces is the measurement of ro... | |
| Glow wire tester,EN 60695 glow wire,Fire hazard tester for electrical insulators | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application It is used in the evaluation of flammability tests and light-off temperature t... |
Same products
| Laser Cutting Machines | Seller: Chanxan (Changshu) Laser Technology Co., Ltd. | Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ... | |
| Precision Laser Micromachining Machine | Seller: Chanxan (Changshu) Laser Technology Co., Ltd. | Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ... | |
| Ultrafast Laser Systems | Seller: Chanxan (Changshu) Laser Technology Co., Ltd. | Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi... | |
| Industrial Laser Equipment Manufacturer | Seller: Chanxan (Changshu) Laser Technology Co., Ltd. | Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan... | |
| Common Rail Injector Valve F00R J02 012 | Seller: 868983 | Common Rail Injector Valve F00R J02 012 David Chen |