Roof-Mounted Photovoltaic Module Fire Test Apparatus | ASTM ISO Testing Machine
Get a quote:
Whats/App: +86 185 0176 3615
Web: qinsun-lab.com
The Roof-Mounted Photovoltaic Module Fire Test Apparatus is a specialized testing system developed in accordance with GB/T 30735-2014 for evaluating the external fire performance of roof-mounted photovoltaic modules and roofing products. Based on test principles derived from ENV 1187 (t1 method) and ISO 12468-1. the apparatus simulates different fire exposure conditions such as wind influence and thermal radiation. It provides standardized test methods for assessing the external reaction to fire of roof systems and roof coverings, supporting fire safety evaluation of photovoltaic installations on roofs.
Application
The test apparatus is suitable for fire performance evaluation of roofing systems and photovoltaic installations under external fire exposure conditions. Typical applications include:
External fire reaction testing of roof-mounted photovoltaic modules
Fire performance evaluation of roof coverings and roofing assemblies
Assessment of building-integrated photovoltaic (BIPV) systems
Combustion behavior testing of roof construction materials
Fire safety research related to renewable energy installations
Type testing and compliance verification in certification and testing laboratories
Standards
The apparatus is designed to meet the requirements of the following standards:
(1) GB/T 30735-2014 – Test Method for Reaction to External Fire of Roofs and Roof Coverings
(2) ENV 1187: t1 – Test Methods for External Fire Exposure to Roofs
(3) ISO 12468-1:2013 (Method B) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods
(4) ISO 12468-1:2013 (Method C) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods
(5) UL 1703: multi-family and hotel room individual dwelling unit smoke detection monitors: electric signal detection of house dust;
(6)UL 790: standard method of fire test for roof covering materials;
(7)ASTM e 108-04: standard method of fire test for roof covering materials;
(8)NFPA 256: fire test of roof deck.
(9)IEC 61730-2 Appendix b: fire tests on PV modules.
Parameters
| Item | Specification |
|---|---|
| Radiant Panel Radiation Surface | 600 mm × 600 mm |
| Wood Crib Fire Gas Combustion Device | 1 set |
| Test Specimen Rack Angle | Adjustable, 0–50° |
| Air Duct Material | SUS304 stainless steel |
| Air Duct Thickness | 2 mm |
| Fan Airflow Capacity | Max. 250 m³/min |
| Fan Power | 5.5 kW |
| Fan Frequency Control | 3-phase 380 V, 5.5 kW |
| Air Duct Adjustable Angle | 0–35° |
| Impeller Anemometer | 3 units |
| Wind Speed Accuracy | 0.1 m/s |
Send product request
Other supplier products
| Shoe Withstand Voltage Testing Machine | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email:info@qinsun-lab。com Standards compliant CAN/CSA-Z195-2002. ANSI-Z41. Tech... | |
| Compressed air filter test bench| Testing Equipment | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The newly developed DFP 3000 compressed air filter test bench provides fully autom... | |
| G031 Fabric Liquid Penetration Time Tester | ASTM ISO Testing Machine | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheG031 Fabric Liquid Penetration Time Testeris designed to measure the liquid pen... | |
| Automatic Thermal Deformation Vicat Softening Point Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com This machine is a non-metallic material testing instrument designed and manufactur... | |
| EN ISO 20344 Footwear Testing Equipment | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Standards compliant ISO-20344 Principle The sample shoes are placed in a contin... |