50th percentile male side impact dummy for automotive crash testing
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The 50th Percentile Male Side Impact Dummy represents an average adult male in terms of body size and mass. Developed based on AMVO 50th percentile male data, and optimized using multiple anthropometric databases covering different populations, this dummy provides high-fidelity biomechanical responses for side impact testing. Its design complies with ISO/TR 9790 evaluation procedures, and has been validated through 33 tests to assess its biofidelity, providing reliable data for vehicle side safety design and occupant injury protection research.
Standards
(1) GB/T 11551 – Protection of occupants in frontal and side collisions
(2) GB 14166 – Motor vehicle seat belts and restraint systems
(3) FMVSS 214 – Side impact protection
(4) UNECE R95 – Lateral collision protection
(5) UNECE R135 – Pole side impact
(6) SAE J1727 – Side impact dummy performance specification
(7) ISO 15830 – Road vehicles – Side impact dummy – Calibration
(8) ISO/TR 9790 – Road vehicles – Side impact dummy – Evaluation method
(9) Euro NCAP – Side impact test protocol
Parameters
Dimensional Data
| No. | Item | Dimension (mm) |
|---|---|---|
| L1 | Sitting height | 869 ±30 |
| L2 | Hip joint pivot height | 79 ±15 |
| L3 | Hip pivot to back distance | 175 ±28 |
| L4 | Thigh gap | 176 ±29 |
| L5 | Foot to knee height | 588 ±30 |
| L6 | Knee to back distance | 670 ±30 |
| L7 | Rear head to back distance | 147 ±22 |
| L8 | Upper rib thorax depth | 208 ±30 |
| L9 | Lower rib/abdomen thorax depth | 228 ±30 |
| L10 | Arm length | 330 ±30 |
| L11 | Arm breadth | 468 ±30 |
| L12 | Waist breadth | 324 ±30 |
Mass Distribution
| Component | Mass (kg) |
|---|---|
| Head | 4.29 ±0.05 |
| Neck | 2.86 ±0.02 |
| Shoulders/Thorax/Abdomen | 20.56 ±0.35 |
| Two half-arms | 3.52 ±0.08 |
| Lumbar spine and pelvis | 19.3 ±0.2 |
| Two thighs | 11.72 ±0.08 |
| Two lower legs (including ankles/feet) | 10.12 ±0.14 |
| Clothing | 1.54 ±0.1 |
| Total dressed dummy weight (with half-arms installed) | 73.91 ±1.02 |
Sensor Configuration
| Location | Sensor | Measurement | Channels |
|---|---|---|---|
| Head | Accelerometer | Acceleration | 1×3 |
| Head | Gyroscope | Angular velocity | 3×1 |
| Head | Tilt sensor | Tilt angle | 1×2 |
| Neck | Upper load cell | Force | 1×6 |
| Neck | Lower load cell | Force | 1×6 |
| Neck T1 | Accelerometer | Acceleration | 1×3 |
| Shoulder | Shoulder joint load cell | Force | 1×3 |
| Spine T4 | Accelerometer | Acceleration | 1×3 |
| Spine T12 | Accelerometer | Acceleration | 1×3 |
| Spine | Gyroscope | Angular velocity | 2×1 |
| Spine | Tilt sensor | Tilt angle | 1×2 |
| Spine | Temperature sensor | Temperature | 1×1 |
| Shoulder/Rib | Temperature sensor | Acceleration | 1×3 |
| 2D IR-TRACC | Displacement sensor | Displacement | 1×1 |
| Thorax/Rib | Accelerometer | Acceleration | 3×3 |
| 2D IR-TRACC | Displacement sensor | Displacement | 3×1 |
| Abdomen/Rib | Accelerometer | Acceleration | 2×3 |
| 2D IR-TRACC | Displacement sensor | Displacement | 2×1 |
| Pelvis | Accelerometer | Acceleration | 1×3 |
| Pelvis | Gyroscope | Angular velocity | 3×1 |
| Pelvis | Tilt sensor | Tilt angle | 1×2 |
| Lumbar spine | Load cell | Force | 1×6 |
| Pubis | Load cell | Force | 1×1 |
| Sacrum | Load cell | Force | 1×6 |
| Femur muscle | Load cell | Force | 2×3 |
| Legs | Thigh load cell | Force | 1×6 |
| Tibia | Upper tibia load cell | Force | 1×6 |
| Tibia | Upper tibia load cell | Force | 1×6 |
| Knee | Load cell | Force | 2×1 |
| Knee | Angle sensor | Angle | – |
Features
(1) Represents a 50th percentile adult male, average body type;
(2) Skeletal and joint design ensures high biofidelity, with accurate thorax and abdomen force responses;
(3) Supports multi-channel measurement of acceleration, force, displacement, angular velocity, tilt, and temperature;
(4) Complete shoulder-rib, thorax-rib, abdomen-rib, and pelvis measurement systems for high-precision injury assessment;
(5) Compliant with international side impact regulations and ISO/TR 9790 evaluation procedures;
(6) Stable structure suitable for repeated side impact tests at various speeds.
Send product request
Other supplier products
| Automated HEPA/ULPA Filter Scanning Test System,High-efficiency filter scanning test bench | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automated HEPA/ULPA Filter Scanning Test System is designed for automated testing of hi... | |
| Contact heating and cooling test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com The sensation of coldness or warmth when skin touches a fabric is referred to as the "coldn... | |
| Solid Auto - ignition Point Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com This tester determines the self - ignition characteristics of solid chemical products by pl... | |
| Smoke Density Chamber (Horizontal Test),Smoke density evaluation device,ISO 5659 | Whats/App: +86 156 1874 6768 Web: standard-groups.com The main principle is to measure smoke density in a particular space, cable or material pro... | |
| Rubber non-rotor vulcanization chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Non-rotor vulcanizer is a rubber processing industry control rubber ... |