Double Plate Thermal Conductivity Apparatus Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The double plate thermal conductivity tester, with an integrated water bath thermostat and computer-controlled measurements, tests thermal conductivity of homogeneous plates (e.g., plastics, rubber, glass) and granular/bulk/soft materials. It is widely used by heat insulation material producers, quality inspection departments, universities, and research institutes.

Application

Building Engineering: Used to evaluate and optimize the thermal performance of building materials to improve the insulation and heat-resistant properties of buildings.

Industrial Engineering: Used to monitor and control the thermal conductivity performance of industrial equipment to improve production efficiency and reduce energy consumption.

Environmental Monitoring: Used to monitor and evaluate the environmental impact of building materials, such as thermal pollution and thermal environment.

Scientific Research: Used to research and develop new materials to improve their thermal conductivity and application value.

The design and operation procedures of these devices ensure the accuracy and reliability of measurements, providing important technical support for the fields of materials science and engineering.

Standards

GB/T 10294-2008:Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials

GB/T 3399-1982:Test method for thermal conductivity of plastics - Heat - resistant plate method

GB/T 10801.1-2002:Thermal insulation polystyrene foam

GB/T 10801.2-2002:Extruded polystyrene foam

GB/T 3139-2005:Test method for thermal conductivity of fiber reinforced plastics

GB/T 17794-2008:Flexible foam rubber and plastic insulation products

ASTM C518:Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

IS0 8301:Thermal Insulation — Determination of Steady-State Thermal Resistance and Related Properties — Heat Flow Meter Apparatus

DIN EN 12667:Thermal Performance of Building Materials and Products - Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods - Products of High and Medium Thermal Resistance

Technical Parameters

Items Parameters
Specimen standard size 300mm × 300mm × H (5 ~ 40) mm
Specimen flatness 0.1mm
Thermal conductivity measurement display range (0.001 ~ 2.000) W / (m • K)
Thermal conductivity measurement accuracy ± 3%
Thermal conductivity measurement Repeatability ± 1%
Temperature resolution 0.01 ℃
Temperature control accuracy 0.05 ℃
Different types of thermal conductivity tester temperature measurement range Model Cold plate temperature control interface ℃ Hot plate temperature control range ℃
IMDRY3001-I Room temperature - 95 ℃ Room temperature - 100 ℃
IMDRY3001-Ⅱ -℃ -5 ℃ - 95 ℃ 15 ℃ - 95 ℃
IMDRY3001-Ⅲ -10 ℃ - 95 ℃ 10 ℃ - 95 ℃
IMDRY3001-IV -15 ℃ - 95 ℃ 5 ℃ - 95 ℃
IMDRY3001-V -20 ° C - 95 ° C 0 ° C - 95 ° C
IMDRY3001-Ⅵ -30 ℃ -95 ℃ -10 ℃ -95 ℃
IMDRY3001-VII -40 ℃- 95 ℃ -20 ℃ - 95 ℃
Power supply AC 220V ± 10%, 2.5KW
Specimen thickness Standard 25mm, range (5 ~ 40) mm
Specimen thermal resistance requirements the thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements.
Clamping force No more than 2.5kPa

Features

Chassis is nice. Test box shell uses spray method. It has strong mechanical strength, anti-corrosion

The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.

High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.

Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.

Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Enamel Boiling Water Resistance meter
Enamel Boiling Water Resistance meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: The enamel layer boiling water weight loss tester is designed accord...
Socks wear tester
Socks wear tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Socks Wear Tester is a specialized testing instrument designed to evaluate the wear res...
KES - G5 Compression Tester
KES - G5 Compression Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Compression Tester analyzes hand movements-particularly, movements by finger-performed ...
ASTM E648 Surface Flame Spread Test Apparatus
ASTM E648 Surface Flame Spread Test Apparatus Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Surface Flame Spread Test Apparatus is a high-precision instrument design...
Infusion Pump Flow Rate Tester ISO & FDA Standard
Infusion Pump Flow Rate Tester ISO & FDA Standard Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Infusion Pump Flow Rate Tester is specifically designed for testing the f...
All supplier products

Same products

Stainless Steel Flux Cored Welding Wire E308T1-1 E308HT1-1 E308LT1-1 Gas Shielded FCAW Wire for 304 Stainless Steel Welding
Stainless Steel Flux Cored Welding Wire E308T1-1 E308HT1-1 E308LT1-1 Gas Shielded FCAW Wire for 304 Stainless Steel Welding Seller: 863048 Product Description stainless steel flux cored wire E308T1-1 E308HT1-1 E308LT1-1,FCAW stainless ...
E317LT1-1 Flux Cored Wire CO2 Stainless Steel 70% Flux Content 1.0/1.2/1.6mm Diameter OEM Customized 1200C Melting Point
E317LT1-1 Flux Cored Wire CO2 Stainless Steel 70% Flux Content 1.0/1.2/1.6mm Diameter OEM Customized 1200C Melting Point Seller: 863048 XUNZHUO STAINLESS STEEL CORED WELDING WIRE E317LT1-1 CLASSIFICATION: There are ones with diamet...
Mini Jewelry Laser Repair System – 60W to 400W Precision Welding
Mini Jewelry Laser Repair System – 60W to 400W Precision Welding Seller: Beijing JCZ Technology Co., Ltd The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre...
Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal
Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal Seller: Beijing JCZ Technology Co., Ltd TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig...
Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner
Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner Seller: Beijing JCZ Technology Co., Ltd The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las...