Fuel Water Separator Test Bench
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
The Fuel Water Separator Test Bench primarily follows ISO/TS 16332-2006 "Diesel engines - Diesel filters - Evaluation of fuel-water separation performance" to test the oil-water separation characteristics of the fuel filter; and performs a cleanliness test on the fuel filter using ISO 4020-2001 "Road vehicles - Fuel filters for diesel engines". The main technical parameters displayed are: test flow rate, system pressure, orifice plate device pressure difference, test specimen pressure difference, and medium temperature.
Applications
The Fuel Water Separator Test Bench is designed to evaluate the water separation performance and cleanliness of fuel filters used in diesel engines. Typical applications include:
Development of new fuel filter products
Comparative performance testing against international products
Quality control during production
Third-party testing and regulatory inspection
The system simulates fuel flow conditions and measures water separation efficiency, differential pressure, system pressure, and cleanliness to ensure accurate filter performance evaluation.
Standards
ISO/TS 16332-2006 – Method for evaluating fuel water separation efficiency of diesel engine fuel filters
ISO 4020-2001 – Road vehicles – Fuel filter test methods for diesel engines
SAE J905-1999 – Diesel fuel filter test methods
Features
Automated Data Acquisition: Key performance parameters such as flow rate, pressure, and differential pressure are automatically recorded
Variable Flow Control: Flow rate regulated using a frequency converter for precise adjustment
Comprehensive Protection: Includes hydraulic protection, electrical protection (leakage, overload), and emergency stop functionality
Robust Construction: Aluminum alloy frame, stainless steel panel with engraved markings, and seamless stainless steel piping ensure durability
Customizable Design: Parameters can be tailored according to customer requirements
Technical Parameters
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | L/h | 60 … 600 or 30 … 300 |
| System pressure | MPa | 1 |
| Medium temperature | °C | Room temp (optional heating/cooling) |
| Water flow rate | mL/min | 1.5 … 200 |
| Orifice plate | – | Domestic or imported |
| Test fuel | – | 0# diesel |
| Test oil tank volume | L | 75 (final design) |
| Water tank volume | L | 15 (final design) |
Send product request
Other supplier products
| Electric rolling wheel peeling testing machine | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Electronic pressure roller testing machine (automatic pressure roller machine) spe... | |
| High Temperature Oxygen Index Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The High-Temperature Oxygen Index (TOI) measuring instrument determines oxygen ind... | |
| Carpet Abrasion Tester | Get a quote: Whats/App: +86 181 0160 0864 The Carpet Abrasion Tester is designed to evaluate the wear resistance of carpets by measuring materi... | |
| Drawer slide durability testing machine | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Drawer Slide Durability Testing Machine is designed to evaluate the mechanical... | |
| Smoke Detector Test Tunnel | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The GB 4715 Smoke Fire Detector Threshold Test Chamber is a precision testing syst... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |