Medical Tube Leak Detection System ISO Compliance Laboratory Equipment
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Catheter Leakage and Compliance Tester is a professional testing device used to evaluate the expansion capacity (compliance) and leak resistance of medical tubing (such as infusion lines, vascular catheters, and respiratory tubing) under varying pressure conditions.
Standards
ISO 13988-1:2017: Intravascular catheters - Part 1
ISO 8536-4:2016: Medical infusion equipment
YY/T 0285.4-2017: Intravascular catheters - Part 4
YY/T 1551.1-2017: Non-intravascular catheters
Features
Color LCD large screen display: Real-time display of test data and statistical values, intuitive and clear.
Intelligent touch control operation: Simple human-machine interface for quick experiment switching.
High-precision electronic flow meter: Achieves precise flow control, avoiding testing errors.
Top-tier sensor system: High-sensitivity data acquisition ensures stable and consistent test results.
Data security management: Four-level access control and encrypted storage prevent unauthorized operations and ensure the integrity and traceability of results.
Convenient result output: Equipped with a micro printer, supporting instant printing of single test results and statistical data.
Technical Parameters
| Parameter | Specification |
|---|---|
| Pressure Range | Determined by test object & application scenarios:- e.g., 0 - 300kPa for medical breathing circuits- Narrower range (e.g., 0 - 50kPa) for routine compliance testing |
| Pressure Accuracy | Key for test accuracy; generally requires ±0.1% or higher (e.g., 0 - 50kPa pressure sensor can reach one-thousandth accuracy) |
| Flow Range | Covers various flow situations of tested catheters; common flowmeter range: 0 - 100L/min |
| Flow Accuracy | Important indicator; generally requires ±1% or higher (e.g., ±1%FS for 2L/min mass flow controller) |
| Volume Measurement Range and Accuracy | - Range: From a few milliliters to several liters (adapts to different catheter volumes)- Accuracy: Generally needs to reach ±0.1ml or higher (to accurately calculate catheter compliance) |
| Test Time Range | - Leakage tests: Flexible setting (a few seconds to several hours)- Compliance tests: Controls pressure change rate & time interval to capture catheter volume changes at different pressure stages |
Accessoriess
Standard accessories include: specialized connectors for different sizes of medical tubing (such as ventilator/anesthesia machine breathing circuits), pressure/flow test tubing, tubing fixing clamps (to ensure sample stability during testing), standard test samples for equipment calibration (including standard leakage and compliance components), operating manual, and calibration certificate.
Send product request
Other supplier products
| Floor Material Burning Performance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM E648-15 Standard test method for critical radiant flux of floor-covering sy... | |
| Smoke Density Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Smoke Density Tester, developed by Rohm and Haas in the 1970s based on ASTM D2843. meas... | |
| Time-Pressure Oxidizing Liquid Analyzer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Conforms to UN Recommendations on the Transport of Dangerous Goods - M... | |
| Spectrophoto meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard CIE No.15. ISO 7724-1: Meets international colorimetry and spectral measurement s... | |
| Ultra-high vacuum tribometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The tester is designed to support test methods referenced in the following stand... |