Medical Face Mask Differential Pressure Tester

Get a quote:

Whats/App: +86 181 0160 0864

Web: gellowen.co.uk

The Medical Face Mask Differential Pressure Tester, also known as the Mask Breathability Tester, is designed to evaluate the breathability of medical face mask materials. The instrument measures the differential pressure (ΔP) required to draw air through a defined surface area at a constant airflow rate. By providing controlled suction through the sample, the tester accurately determines the air exchange pressure and comfort performance of mask materials, which is essential for medical mask quality assessment.

Application

The Medical Face Mask Differential Pressure Tester is applicable to breathability evaluation across the following industries and products:

(1) Medical and Healthcare Industry: surgical masks, medical face masks, N95/FFP masks, disposable masks — evaluation of breathability and air exchange resistance

(2) Protective Clothing Industry: mask-integrated protective garments, isolation gowns with mask functionality — assessment of airflow and wearer comfort

(3) Textile Industry: nonwoven fabrics, filter fabrics, coated fabrics — air permeability and differential pressure testing

(4) Research and Development: development of new mask materials, optimization of air permeability and comfort, comparative studies

(5) Quality Control: production batch verification, mask material compliance testing for breathability standards

(6) Third-Party Testing Laboratories: certification testing, laboratory evaluation of mask differential pressure and comfort properties

The instrument is widely used for product development, quality control, R&D, and laboratory testing.

Standards

The instrument complies with and can be applied to the following standards (including but not limited to):

(1) YY 0469-2011 – Technical Requirements for Medical Surgical Masks

(2) YY/T 0969-2013 – Medical Face Masks — Air Permeability and Breathability Testing

(3) EN 14683:2014, Annex C – Medical Face Masks — Requirements and Test Methods (Differential Pressure)

(4) ASTM F2100 – Standard Specification for Performance of Materials Used in Medical Face Masks

Features

(1) Suction air source, not limited by the test site space

(2) High-precision differential pressure sensor with digital display of ΔP across the sample

(3) Special sample holder ensures firm positioning of the mask material

(4) Automatic measurement of air exchange pressure and evaluation of material comfort

(5) Compact and easy-to-operate design suitable for laboratory and production environments

Technical Parameters

ItemSpecification
Flow Meter Range 0 – 10 L/min
Manometer Range & Accuracy 0 – 1000 Pa, ±1 Pa
Internal Diameter of Sample Holders Φ25 mm
Test Area 4.9 cm²
Power Supply 220 V, 50 Hz, 200 W
Weight 65 kg

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Nasal Oxygen Cannula Tester
Nasal Oxygen Cannula Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk This device is used to test various performance characteristics of nasal cannulas,...
Rapid Crack Propagation Tester / RCP Tester
Rapid Crack Propagation Tester / RCP Tester Standard ISO 13477: Designed exclusively for determining critical pressure (Pc) and temperature (Tc) in polyethylene pressure pipes during rapid c...
Fabric Water Absorption Tester
Fabric Water Absorption Tester Getaquote: Whats/App: +86 181 0160 0864 Fabric Water Absorption Tester is designed to test the ability of terry fabric to rapidly absorb and reta...
Textile moisture absorption and heat generation performance tester
Textile moisture absorption and heat generation performance tester Get a quote: Whats/App: +86 181 0160 0864 The Textile Moisture Absorption and Heat Generation Performance Tester is a professional laboratory ins...
Helmet UV Pretreatment Box Tester / Helmet UV pretreatment box
Helmet UV Pretreatment Box Tester / Helmet UV pretreatment box Product Introduction Helmet ultraviolet pretreatment box is used for helmet ultraviolet irradiation pretreatment, according to the new national st...
All supplier products

Same products

Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 Seller: 868983 Common Rail Injector Valve F00R J02 012 David Chen
Common Rail Injector Valve F00R J02 005
Common Rail Injector Valve F00R J02 005 Seller: 868983 Common Rail Injector Valve F00R J02 005 David Chen
Common Rail Injector Valve F00R J01 945
Common Rail Injector Valve F00R J01 945 Seller: 868983 Common Rail Injector Valve F00R J01 945 David Chen
Common Rail Injector Valve F00R J01 941
Common Rail Injector Valve F00R J01 941 Seller: 868983 Common Rail Injector Valve F00R J01 941 David Chen
Common Rail Injector Valve F00R J01 924
Common Rail Injector Valve F00R J01 924 Seller: 868983 Common Rail Injector Valve F00R J01 924 David Chen