The Dry Microbial Penetration Resistance Tester assesses material resistance to dry bacteria-carrying particles (like human dandruff-sized). It tests protective gear (surgical gowns, etc.) per ISO 22612. part of EN 13795 and EN 14126 test suites. Compliance with EN 13795 aligns with EU Medical Device Directive 93/42/EEC, crucial for CE marking in Europe.

Application:

Dry microbial penetration resistance performance tester is professionaly used to determine the bacterial penetration resistance performance of materials to dry particulates in the size range of human body dandruff.Whenn testing, the samples were fixed on a container respectively.In these containers, five containers containing subtilisin talc, one container added with Not stained talcum powder was used as a control.A Petri dish was inserted at the bottom of each container at a distance from the bottom of the timer.

The equipment supporting the container is oscillated by a Gas ball oscillator, and all the talc penetrating the sample Falled on the culture dish , cultured without the culture vessel.The test results were evaluated by counting the growing colonies.

Standards:

ISO 22612:Clothing for protection against infectious agents - Test method for resistance to dry microbial penetration

YY / T 0506.5-2009:Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 5: Test method for resistance to dry microbial penetration

Features:

Reliable design, stable test;

Front switch glass doors, easy to observe the operation of the experimental staff;

Removable bracket, height adjustable bracket;

Support, mobile dual casters;

Negative pressure experimental system, with the fan exhaust system and the introduction of high efficiency filter to ensure the safety of operators;

Embedded high - speed industrial microcomputer control;

Dedicated operating software, with software parameters calibration, fault detection automatically

Test principle:

When testing, the samples were seperately fixed on a container.In these containers, five containers carrying the bacillus subtilis and 1 container carrying uncontaminated talc powder used as control.Insert 1 petri dish at the bottom of each container and beneathe the bottom of the specimen.

The supporting vessel's equipment is oscillated by a gas ball type oscillator, and all of the talcum powder passing through the sample falls onto the petri dish. Remove the petri dish for culture. The experiment results were evaluated by counting the colonies.

Main parameters:

Parameter NameParameter Value
Vibration form pneumatic ball vibrator
Vibration frequency 20800 times/min
Vibration force 650N
Worktable size 40cm × 40cm × 10mm
Workbench media marble plate
Experimental container stainless steel test container
Work stations 6
Cabinet negative pressure range -50 Pa ~ -200 Pa
High efficiency filter filtration efficiency better than 99.99%
Negative pressure cabinet ventilation flow ≥ 5m³/min
Data storage capacity 100.000 group
Working voltage 220V 50HZ

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Auto - ignition Point Tester for Liquids / ASTM E659
Auto - ignition Point Tester for Liquids / ASTM E659 Standards This product complies with GB/T 21860 - 2008 *Test Method for Auto - ignition Temperature of Liquid Chemicals* and ASTM E659 - 78(2005) ...
Autocatalytic Decomposition Temperature Tester with Thermal Insulation
Autocatalytic Decomposition Temperature Tester with Thermal Insulation Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Autocatalytic Decomposition Temperature Tester with Thermal Insulation (Adiaba...
Drum and Reciprocating Friction and Wear Testing Machine
Drum and Reciprocating Friction and Wear Testing Machine Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Drum and Reciprocating Friction and Wear Testing Machine is a dual-function tr...
Coating thickness gauge/film thickness gauge
Coating thickness gauge/film thickness gauge Standard Coating Thickness Gauge complies with international standards includingASTM B499.ASTM D1400.ISO 2178.ISO 2360. andGB/T 4956. ensuring rel...
Model Coin-cell Swelling System
Model Coin-cell Swelling System Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Model Coin-Cell Swelling System is designed for in-situ measurement of thickne...
All supplier products

Same products

Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 Seller: 868983 Common Rail Injector Valve F00R J02 012 David Chen
Common Rail Injector Valve F00R J02 005
Common Rail Injector Valve F00R J02 005 Seller: 868983 Common Rail Injector Valve F00R J02 005 David Chen
Common Rail Injector Valve F00R J01 945
Common Rail Injector Valve F00R J01 945 Seller: 868983 Common Rail Injector Valve F00R J01 945 David Chen
Common Rail Injector Valve F00R J01 941
Common Rail Injector Valve F00R J01 941 Seller: 868983 Common Rail Injector Valve F00R J01 941 David Chen
Common Rail Injector Valve F00R J01 924
Common Rail Injector Valve F00R J01 924 Seller: 868983 Common Rail Injector Valve F00R J01 924 David Chen