.

High Precision Thermal Conductivity Measurement Platform Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The platform supports internationally recognized absolute measurement standards, including:

(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method

(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source

(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials

(4) ASTM E3088: Determination of thermal conductivity and thermal diffusivity using the transient plane source method

(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids

(6) ASTM D5334: Transient line-source probe method

(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique

Parameters

MethodTPSTHWMTPSTLS
Applicable Materials Solids, pastes, powders Liquids, phase-change materials Solids, pastes, powders Soil, pastes, polymers
Measurement Module 3D bulk, anisotropic, plate, thin film; general: specific heat Bulk 3D bulk, anisotropic, plate; 1D standard Bulk
Thermal Conductivity (W/m·K) 0.01–500 0.01–2 0.03–500 0.1–8
Thermal Diffusivity (mm²/s) 0.01–300 Up to 0.5 0.01–300 Not applicable
Volumetric Heat Capacity (MJ/m³·K) Up to 5 Up to 5 Up to 5 Not applicable
Thermal Effusivity (W·s½/m²·K) 20–40000 Not applicable 20–40000 Not applicable
Sample Size (mm mL) Ø10 or square 20 mL Ø25 or square
Sample Thickness (mm) ≥0.05 Not applicable ≥0.1 Probe length 100
Maximum Sample Size Unlimited Unlimited Unlimited Unlimited
Test Time (s) 2–160 1 2–160 180
Accuracy (Thermal Conductivity) 5% 2% 5% 5%
Repeatability (Thermal Conductivity) 2% 1% 2% 2%
Temperature Range (°C) 0–300 / −75–300 −50–200 0–100 / −50–200 −40–100
Sample Configuration Symmetric / asymmetric Insert type Asymmetric (single-sided) Insert type
Supported Standards ISO 22007-2. ISO 22007-7. GB/T 32064. ASTM E3088 ASTM D7896 ISO 22007-7 ASTM D5334. ASTM D5930

Features

Absolute measurement methods with no calibration materials required

Multiple transient techniques integrated on a single platform

Direct measurement of thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity

Suitable for solids, liquids, pastes, powders, and soil

Raw data–based calculation improves traceability and measurement reliability

Accessories

(1) TPS sensors for solids, pastes, and powders

(2) THW sensors for liquid measurements

(3) MTPS sensors for single-sided solid measurements (optional)

(4) TLS probe sensors for soil and polymer testing (optional)

(5) Dedicated sample holders and probe assemblies


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Automatic Water Separation Test System
Automatic Water Separation Test System Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:De...
Carpet Abrasion Resistance Test device
Carpet Abrasion Resistance Test device Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM D4157(Standard Test Method for Abrasion Resistance of Textile Fabrics (Osc...
Smoke Fire Detector Threshold Test Chamber
Smoke Fire Detector Threshold Test Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system conforms to the following national and international standards: GB 4...
Cork Puncture and Chip Detection Instrument
Cork Puncture and Chip Detection Instrument Whats/App: +86 156 1874 6768 Web: standard-groups.com The rubber stopper puncture debris detector is a device specifically used to detect the num...
Ring-on-Block Friction and Wear Test Equipment Model 2M
Ring-on-Block Friction and Wear Test Equipment Model 2M Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 3960-2016 Plastics – Determination of Sliding Wear Properties GB/T 3...
All supplier products

Same products

HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...
PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...