Computer controlled memory impact testing machine
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
Computer controlled memory impact testing machine is mainly used for hard plastics, reinforced nylon, glass steel, ceramics, cast stone, electrical insulation materials and other non-metallic materials impact toughness determination. The testing machine is an ideal test equipment for chemical industry, scientific research units, colleges and universities, quality testing departments, professional manufacturers laboratories and other units. It is a testing instrument with simple structure, convenient operation and accurate and reliable data.
Computer controlled memory impact testing machine is mainly used for hard plastics, reinforced nylon, glass steel, ceramics, cast stone, electrical insulation materials and other non-metallic materials impact toughness determination. The testing machine is an ideal test equipment for chemical industry, scientific research units, colleges and universities, quality testing departments, professional manufacturers laboratories and other units. It is a testing instrument with simple structure, convenient operation and accurate and reliable data.
Application
Tapered twin-screw extruders are primarily used for direct forming of pipes, sheets, and profiles from materials such as rigid polyvinyl chloride (UPVC), while also serving as plastic modifiers and pelletizers for powder materials. With different molds, they can directly extrude sheets, pipes, and profiles for experimental purposes.
Standards
JB/T 11343-2013:Martindale Abrasion and Pilling Tester
JB/T 5420-2014:Fabric Abrasion Tester
JB/T 6492-2014:Fabric Pilling Tester
JB/T 6491-2015:Fabric Snagging Tester
T/GDPIA 21-2020:Test Method for Abrasion and Pilling Resistance of Textiles (Martindale Method)
T/GDPIA 16-2020:Test Method for Fabric Pilling Resistance
T/GDPIA 22-2020:Test Method for Fabric Snagging Resistance
T/ZZB 1351-2019:Specification for Fabric Abrasion and Pilling Tester
T/CPMIA 0201-2022:Test Method for Abrasion Resistance of Textile Materials (Martindale Method)
Features
Screw Structure and Motion:
Conical Design: The feed section features a larger diameter, while the homogenizing section has a smaller diameter, creating a forced thrust to prevent material overheating.
Counter-Rotation: Two screws mesh in opposite directions, conveying material axially through the screw gap while applying shear force. Ideal for processing plastics like PVC and polyolefins.
Plasticizing and Extrusion Process:
Heating and Cooling: Built-in cast aluminum heaters and cooling fans within the barrel, combined with gradient temperature control technology, precisely regulate the processing temperature range.
Vacuum Degassing: Ensures uniform plasticization and minimizes bubbles and impurities through a vacuum degassing system.
Energy Efficiency and Environmental Protection:
Variable Frequency Drive: Compatible with VFD motors for energy-saving operation.
Waste Heat Recovery: Selected upgraded models incorporate waste heat recovery systems to further enhance energy efficiency.
Technical Parameters
| Category | Specification |
|---|---|
| Impact Energy | 2/4 J (simply supported beam); 2.75/5.5 J (cantilever) |
| Sampling Rate | 10 µs |
| Resolution | 16 bits |
| Load Measurement Accuracy | ≤ 1% |
| Impact Knife Angle | 30° |
| Pendulum Torque (Simply Supported Beam) | 2.1436 Nm, 1.0718 Nm, 0.5359 Nm |
| Pendulum Torque (Cantilever Beam) | 2.9474 Nm, 1.4737 Nm |
| Pendulum Pre-lift Angle | 150° |
| Simply Supported Beam | |
| Impact Speed | 2.9 m/s |
| Distance from Pendulum Shaft Center to Sample Center | 230 mm |
| Blade Angle | 30° |
| Blade Radius | 2 mm |
| Support Corner Radius | 1 mm |
| Support Front Angle | 5° |
| Support Rear Angle | 10° |
| Support Span | 40. 60. 70 mm |
| Sample Type and Size (L × W × T) | 380×10×4 mm, 50×6×4 mm, 120×15×10 mm |
| Cantilever Beam | |
| Impact Speed | 3.5 m/s |
| Distance from Pendulum Shaft Center to Sample Center | 335 mm |
| Blade Angle | 75° |
| Blade Radius | 0.8 mm |
| Front Edge Angle | 5° |
| Blade Back Angle | 10° |
| Sample Type and Size (L × W × T) | 80×10×4 mm63.5 × 12.7 × 12.7 mm63.5 × 12.7 × 6.4 mm63.5 × 12.7 × 3.2 mm |
Send product request
Other supplier products
| Sauce Packet Pressure Testing Instrument | The pressure resistance tester for sauce packets is a device specifically designed to test the pressure - resistance performance of soft packaging ... | |
| New warm body dummy tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk In addition to heat dissipation to the surrounding environment through conduction,... | |
| 50th Percentile Male Side Impact Dummy | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The 50th Percentile Male Side Impact Dummy represents an average adult male in ter... | |
| Suture Needle Cutting Force Tester YY 0166 | The Cutting Force Tester for Suture Needles is a precision instrument specifically used to detect the force required by medical suture needles duri... | |
| Shoelace Abrasion Tester / SATRA TM93 / QB/T2226 | Standards SATRA TM93、DIN-4843、QB/T2226、SATRA TM154 Principle Let shoelace cross the eyelet clamped on the fiber board, make the shoelace and eye... |
Same products
| Common Rail Injector Valve F00R J02 012 | Seller: 868983 | Common Rail Injector Valve F00R J02 012 David Chen | |
| Common Rail Injector Valve F00R J02 005 | Seller: 868983 | Common Rail Injector Valve F00R J02 005 David Chen | |
| Common Rail Injector Valve F00R J01 945 | Seller: 868983 | Common Rail Injector Valve F00R J01 945 David Chen | |
| Common Rail Injector Valve F00R J01 941 | Seller: 868983 | Common Rail Injector Valve F00R J01 941 David Chen | |
| Common Rail Injector Valve F00R J01 924 | Seller: 868983 | Common Rail Injector Valve F00R J01 924 David Chen |