Textile Blanket Flammability Tester Complying with 16 CFR Standards
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Features
Stainless steel body design
External gas control;Separation design of fire source is safe and reliable, it has the functions of fine gas adjustment and coarse adjustment; The instrument with stainless steel main body is resistant to high temperature and smoke, easy to clean and long service life.
time recording module
High precision digital display timer with 0.1s accuracy, built in standard 1s ignition time, automatically burns and records the time.
flexible specimen holder design
The positioning accuracy of the sample holder ensures the consistency of the position of each combustion and reduces the uncertainty of the test, thus ensuring the accuracy of the test.
Standard burner
The burner of the instrument adopts the standard 18# needle. The compact design ensures the stability of the flame, and it is automatically reset to prepare for the next test after each ignition. It is very convenient to use.
Technical Parameters
|
Burn timer:timer (accurate to 0.01s) |
|
|
Exhaust vent (top) : $12.7mmX12 |
Igniting time:1S |
|
viewing window: transparency |
Windshield size: 368.3x6.35x25.4mm, 12 ga (w*h) |
|
Standard flame height: 16mm |
Size of the tBox central substrate size:370x217.5x25.4mm |
|
Sample holder upper plate :round hole |
burning chamber diamensions (LxWxH) :373x219x357mm |
|
D: 63.5mm, 88.9x88.9x3.175mm |
Diamension (LxWxH) :373x219x515mm |
|
sample holder lower plate:round hole |
weight: 35Kg |
|
D: 63.5mm, 76.2x88.9x3.175mm |
power: 220V 50HZ |
Test Procedures
●After the sample is ready and the instrument is commissioned, place the assembled sample clamp on the specimen holder.
●Open the gas valve and supply the gas to the fire pipe. Use the electronic igniter to fire the burner
●Press the start button on the control panel. The fire tube moves forward and moved to the test position under the action of the mechanical transmission. Then, Start the ignition of the sample and test paper on the sample holder
●At the same time to start the ignition timing system, the control panel display and record the ignition time. After a second, the fire tube moving backwards, the timer stop time. The experiment is end.
●Finally remove the sample and test paper for rating.
Send product request
Other supplier products
| Spectrophotometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard CIE No.15. ISO 7724-1: Meets international colorimetry and spectral measurement s... | |
| SDC Fading Grey Scale | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 105-A02(Grey Scale for Assessing Change in Color) AATCC Evaluation Proced... | |
| Incline Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM D7748: Impact resistance testing of packaging and transport systems. ISO ... | |
| High low temperature gravel impact tester for automotive coatings | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The tester complies with and supports evaluation methods defined in the followin... | |
| Electronic Crockmeter Rubbing Fastness Tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The G238AA Manual Rubbing Color Fastness Tester is the most commonly used mod... |