Limiting Oxygen Index Tester Manufacturer in China

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Features

Imported sensors

Imported Paramagnetic oxygen concentration sensor with high precision and stable performance.Real-time detection of oxygen concentration with PLC precise control so that can adjust the oxygen concentration through the airflow.

Flexible fixture design

The fixture is made of refractory and stainless material, which can resist high temperature and rust.It can hold various samples.By replacing the sample holder, the sample requirements of different characteristics can be fulfilled.

Linited Oxygmn Indes Testet

Intelligent touch operation 7-inch color screen, intelligent touch, multi-touch operating system, convenient operation, multi-language display, switching between

Chinese and English.Simplified operation interface, easy to operate

Quick change structural design

The test tube of this instrument which is made of high temperature resistant transparent glass combing with the base adopts quick change design to clearly observe the combustion situation in the test. Moreover, it is easy to clean after the test. The stainless steel base can avoid the influence of various corrosion on the test data, and its service life is long.

Parameters

Operating mode: Full color touch screen control

Control range:0~100%, ±0.2%

Language:Chinese-English interface

Inlet air pressure:≤1MPa

Burner:Inner Radius79mm;height500mm

test air pressure:0.15-0.2MPa

Glass beads: 4mm,height 80-100mm

Gas flow rate: 12.01L/min

Igniter inner diameter:2mm

Dimension:700 mmx750mmx460 mm

Igniter length:400mm

Weight:45kg

Air inlet: 7mm

Power supply:220V 50Hz

Test Procedure

Install the sample and adjust the burner angle.

Adjust the O₂/N₂ flow rate to the initial concentration (e.g., 18% or 25%).

Ignite the sample and record the burning time or flame front position.

Adjust the oxygen concentration based on the burning behavior, and repeat the test until the accuracy requirements are met (the difference between three test results < 0.5%).

Result Analysis: Calculate the average of the three oxygen concentrations to determine the LOI value of the material.

Safety Precautions

Personal Protective Equipment: Operators must wear safety glasses and gloves to avoid injury from smoke or flames.

Gas Management:

The purity of the oxygen cylinder must be calibrated regularly, and the nitrogen cylinder pressure should not be less than 1MPa.

Adjust the flow rate evenly to avoid sudden changes in gas pressure.

Equipment Maintenance:

Regularly clean the combustion tube and igniter, and remove combustion residue.

If any problems occur, please contact professional personnel for repair; do not disassemble components yourself.

Ventilation Requirements: The test must be conducted in a fume hood to prevent the accumulation of exhaust gases.

Maintenance Information

(1) Clean the combustion tube and igniter regularly to remove residue.

(2) Inspect oxygen and nitrogen cylinders for proper pressure and purity.

(3) Avoid disassembling critical components; contact professional personnel for repairs.

(4) Ensure proper ventilation to avoid accumulation of exhaust gases.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

High Low Temperature Test Chamber
High Low Temperature Test Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1.Adopt advanced temperature control system, the controller accordin...
Pipe coating scratch meter
Pipe coating scratch meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Paint and varnish scratch resistance tester, also known as scratch r...
MVSS Combustion Tester
MVSS Combustion Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Mainly used for combustion performance testing of automotive interior materials, etc. Appl...
Drainage sheet horizontal permeability tester
Drainage sheet horizontal permeability tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Plastic Drainage Board Horizontal Water Flow Tester is used to determine the characteri...
Constant Elongation Tensile Stress Tester ISO 13934
Constant Elongation Tensile Stress Tester ISO 13934 Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Usage Constant tensile stress meter is an instrument to determine the tensil...
All supplier products

Same products

Gasket for Plate Heat Exchanger
Gasket for Plate Heat Exchanger Seller: Hengshui Hongcan Import and Export Trading Co., Ltd The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ...
Energy Saver
Energy Saver Seller: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
ER1100 Aluminum Welding Wire
ER1100 Aluminum Welding Wire Seller: 868776 The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ...
air conditioner
air conditioner Seller: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...