Smoke Detector Test Tunnel Manufacturer | EN 54 & UL 268 Fire Alarm Testing Equipment
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Unit | Specification |
|---|---|
| Temperature Range | 0–55 °C, adjustable via heating rods |
| Variable Frequency Fan | Supply voltage: 220 V; Max. static pressure: 330 Pa; Adjustable air volume: 0–275 m³/h |
| Airflow Requirement | 0.2 m/s |
| Optical Density Meter | Wavelength: 880–950 nm |
| Omega K-Type Sheathed Thermocouple | Diameter: 1.5 mm; Temperature measurement range: 0–1100 °C |
Features
Steel structure chamber with anti-rust spray finish.
Observation glass on the chamber for visual monitoring of smoke distribution.
Independent control box for flexible laboratory layout.
Fan connected with soft couplings to reduce vibration impact on test data.
Equipped with an ion concentration meter to test the response threshold of ionization detectors.
Flash device included to simulate environmental lighting conditions.
Siemens dedicated temperature module for stable and reliable temperature data acquisition.
Imported Omega thermocouple with compensation wiring reduces temperature measurement deviations.
Programmable logic controller (PLC) enables system function control, paired with dedicated data acquisition modules.
Real-time data acquisition ensures stability and reliability.
Electrical components from reputable industry brands, controlled via industrial PC with dedicated software for real-time recording, storage, and visualization of test data.
Accessories
Observation glass
Variable frequency fan assembly
Heating rod modules
Optical density meter
Ion concentration meter
Flash simulation device
Omega K-type thermocouple and compensation wiring
Siemens temperature acquisition module
PLC controller with data acquisition modules
Industrial PC and dedicated software
Test Procedures
Install the smoke fire detector into the test chamber.
Power on the chamber and set the target temperature within 0–55 °C.
Activate the variable frequency fan and adjust airflow to 0.2 m/s.
Initiate the smoke generation process and monitor optical density readings.
Conduct threshold, repeatability, orientation, and airflow tests according to GB 4715-2005 protocols.
Use ion concentration meter to verify ionization detector response, if applicable.
Apply flash simulation to assess detector response under different lighting conditions.
Record all data in real time using the industrial PC and dedicated software for analysis.
Send product request
Other supplier products
| Femoral Stem Fatigue Performance Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0809.4 (China): Specifies fatigue testing protocols for femoral stems in par... | |
| Fabric Touch Cool Feeling Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Fabric Cooling Sensation Tester is used to evaluate the instant cooling sensa... | |
| Custom Leakage negative pressure tester for infusion device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for leakage testing of medical infusion devices in the ... | |
| Finger Abrasion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Universal Finger Abrasion Tester can simulate virtually all wear processes in... | |
| Flexometer / Bally type flexometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Bally flex tester is designed to evaluate the flexural resistance of leather to continual f... |