Single-Use Pulmonary Balloon Dilatation Catheter
Used for endoscopic dilate strictures of the airway tree
Features of Single-Use Pulmonary Balloon Dilatation CatheterCatheter
Three distinct diameters could be achieved with one balloon.
Radiopaque markers enable precise placement within a stricture.
Special catheter structure design, ensures the efficiency of inflation and deflation.
Compatible with 0.035" Guidewire.
Available for Minm. 2.0mm working channel.
Specification of Single-Use Pulmonary Balloon Dilatation Catheter
|
Ref |
Balloon |
Catheter |
Minimum Working Channel (mm) |
Unit/Box |
||||
|
Length(mm) |
|
Normal Pressure(atm) |
|
Length(cm) |
Structure |
|||
|
L26A0630 |
30 |
6-7-8 |
3-6-9 |
5 |
110 |
OTW |
2 |
1 |
|
L26A0830 |
30 |
8-9-10 |
3-6-9 |
5 |
110 |
OTW |
2 |
|
|
L26A1030 |
30 |
10-11-12 |
3-6-9 |
5 |
110 |
OTW |
2 |
|
|
L26B0630 |
30 |
6-7-8 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B0830 |
30 |
8-9-10 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1030 |
30 |
10-11-12 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1230 |
30 |
12-13.5-15 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1530 |
30 |
15-16.5-18 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B0655 |
55 |
6-7-8 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B0855 |
55 |
8-9-10 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1055 |
55 |
10-11-12 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1255 |
55 |
12-13.5-15 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1555 |
55 |
15-16.5-18 |
3-4.5-6 |
6 |
110 |
OTW |
||
|
L26B1855 |
55 |
18-19-20 |
3-4.5-6 |
6 |
110 |
OTW |
||
Available for specific region, please consult with sales representative for details
Leomed provides endoscope accessoriesin Gastroenterology, Respirology, as well as the medical devices used in PAD.
Send product request
Other supplier products
| Single-use ERCP Guidewire | Ercp guidewire is used for guiding the catheter or other devices to the digestive tract for interventional diagnostic and surgery endoscopic. Fe... | |
| PTA Balloon Dilatation Catheter | The PTA dilatation catheteris used for PTA(Percutaneous Transluminal Angioplasty) procedure in the peripheral vasculature, including but not limite... | |
| Rotatable Sphincterotome | Leo Medical Co.,Ltd. is committed to providing affordable and qualified endoscope accessoriesin Gastroenterology, Respirology, as well as the medic... | |
| Single-Use Airway Retrieval Basket | This bronchoscopic basketis used for endoscopic removal of foreign bodies from airway. Features of Single-Use Airway Retrieval Basket The bro... | |
| Rotatable Sphincterotome | Rotatable sphinctertomeis used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP operation in the stenosis ... |