Thrombite™ Clot Retriever Device
More efficient choice of recanalization
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ Clot RetrieverDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Stent Retriever Procedure Is Performed
Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.
INDICATIONS
Thrombite™ Clot Retriever Device
The Thrombite™ clot retrieval deviceis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.
Zyloxton-bridgeprovides endovascular clot retrieval devices, stent retriever devices, clot retrieval, stent retrieval device, etc. Want to know more, contact us.
Send product request
Other supplier products
| Peripheral Stent System | OVERVIEW Peripheral Stent System The ZENFLEX® peripheral vascular disease stentsystem is designed to deliver a self-expanding stent to the il... | |
| Aneurysm Coils | OVERVIEW Coil Aneurysm Brain The Ton-Bridge super soft coils are the neurovascular embolization coilsdesigned for the embolization of intracrania... | |
| Snare Retrieval Kit for IVC Filter | zyloxprovides ivc filter retrieval kit, ivc tel, etc. Want to know more about ivc technology, contact us. | |
| ZENFlow Tiger™ LD PTA Dilatation Catheter | OVERVIEW ZENFlow Tiger™ LD PTA Dilatation Catheter Large balloon diameters up to 25mm A unique low temperature molding technology, ensur... | |
| OVERVIEW | The Cylone™ aspiration catheter, featuring an end-to-end coil and braid construction, ensures easy navigation to the M1 and M2 segments and e... |
















